Volumn , Issue , 1999, Pages 639-647
|
Laboratory examination results from Oconee Nuclear Station once through steam generator tubes
a a |
Author keywords
[No Author keywords available]
|
Indexed keywords
AUGER ELECTRON SPECTROSCOPY;
NONDESTRUCTIVE EXAMINATION;
NUCLEAR POWER PLANTS;
SCANNING ELECTRON MICROSCOPY;
STEAM GENERATORS;
TUBES (COMPONENTS);
X RAY PHOTOELECTRON SPECTROSCOPY;
ANALYTICAL TRANSMISSION ELECTRON MICROSCOPY;
FREE SPAN AXIALLY ORIENTED INTERGRANULAR CORROSION;
ONCE THROUGH STEAM GENERATOR TUBES;
SECONDARY ION MASS SPECTROSCOPY;
CORROSION;
|
EID: 0033489403
PISSN: None
EISSN: None
Source Type: Conference Proceeding
DOI: 10.1002/9781118787618.ch66 Document Type: Conference Paper |
Times cited : (6)
|
References (14)
|