메뉴 건너뛰기




Volumn 37, Issue 4, 1999, Pages 275-283

Enhanced immunofluorescence measurement resolution of surface antigens on highly autofluorescent, glutaraldehyde-fixed cells analyzed by phase- sensitive flow cytometry

Author keywords

Cellular autofluorescence; Fibroblasts; Fluorescence lifetime; Fluorescent microspheres; Glutaraldehyde; Phase sensitive detection

Indexed keywords

GLUTARALDEHYDE; MEMBRANE ANTIGEN;

EID: 0033485335     PISSN: 01964763     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-0320(19991201)37:4<275::AID-CYTO4>3.0.CO;2-U     Document Type: Article
Times cited : (17)

References (33)
  • 1
    • 0018763698 scopus 로고
    • Autofluorescence of viable cultured mammalian cells
    • Aubin JE. Autofluorescence of viable cultured mammalian cells. J Histochem Cytochem 1979;27:36-43.
    • (1979) J Histochem Cytochem , vol.27 , pp. 36-43
    • Aubin, J.E.1
  • 3
    • 0020788928 scopus 로고
    • Flow-cytometric monitoring of intracellular flavins simultaneously with NAD(P)H levels
    • Thorell B. Flow-cytometric monitoring of intracellular flavins simultaneously with NAD(P)H levels. Cytometry 1983;4:61-65.
    • (1983) Cytometry , vol.4 , pp. 61-65
    • Thorell, B.1
  • 6
    • 0030805839 scopus 로고    scopus 로고
    • Reducing cellular autofluorescence in flow cytometry: An in situ method
    • Mosiman VL, Patterson BK, Canterero L, Goolsby CL. Reducing cellular autofluorescence in flow cytometry: an in situ method. Cytometry 1997;30:151-156.
    • (1997) Cytometry , vol.30 , pp. 151-156
    • Mosiman, V.L.1    Patterson, B.K.2    Canterero, L.3    Goolsby, C.L.4
  • 7
    • 0025812860 scopus 로고
    • Quenching of intracellular autofluorescence in alveolar macrophages permits analysis of fluorochrome-labeled surface antigens by flow cytometry
    • Halldén G, Sköld CM, Eklund A, Forslid J, Hed J. Quenching of intracellular autofluorescence in alveolar macrophages permits analysis of fluorochrome-labeled surface antigens by flow cytometry. J Immunol Meth 1991;142:207-214.
    • (1991) J Immunol Meth , vol.142 , pp. 207-214
    • Halldén, G.1    Sköld, C.M.2    Eklund, A.3    Forslid, J.4    Hed, J.5
  • 8
    • 0022820657 scopus 로고
    • Cell-by-cell autofluorescence correction for low signal-to-noise systems: Application to epidermal growth factor endocytosis by 3T3 fibroblasts
    • Roederer M, Murphy RF. Cell-by-cell autofluorescence correction for low signal-to-noise systems: Application to epidermal growth factor endocytosis by 3T3 fibroblasts. Cytometry 1986;7:558-565.
    • (1986) Cytometry , vol.7 , pp. 558-565
    • Roederer, M.1    Murphy, R.F.2
  • 9
    • 0028894703 scopus 로고
    • Autofluorescence correction for fluorescence in situ hybridization
    • Szöllösi J, Lockett SJ, Balázs M, Waldman FM. Autofluorescence correction for fluorescence In Situ hybridization. Cytometry 1995;20: 356-361.
    • (1995) Cytometry , vol.20 , pp. 356-361
    • Szöllösi, J.1    Lockett, S.J.2    Balázs, M.3    Waldman, F.M.4
  • 10
    • 0023154201 scopus 로고
    • A single laser method for subtraction of cell autofluorescence in flow cytometry
    • Alberti S, Park DR, Herzenberg LA. A single laser method for subtraction of cell autofluorescence in flow cytometry. Cytometry 1987;8:114-119.
    • (1987) Cytometry , vol.8 , pp. 114-119
    • Alberti, S.1    Park, D.R.2    Herzenberg, L.A.3
  • 11
    • 0025893634 scopus 로고
    • Immunofluorescence analysis in flow cytometry: Better selection of antibody-labeled cells after fluorescence overcompensation in the red channel
    • Alberti S, Bucci C, Fornaro M, Robotti A, Stella M. Immunofluorescence analysis in flow cytometry: better selection of antibody-labeled cells after fluorescence overcompensation in the red channel. J Histochem Cytochem 1991;39:701-706.
    • (1991) J Histochem Cytochem , vol.39 , pp. 701-706
    • Alberti, S.1    Bucci, C.2    Fornaro, M.3    Robotti, A.4    Stella, M.5
  • 12
    • 0027160335 scopus 로고
    • Fluorescence spectral overlap compensation for any numbers of flow cytometry parameters
    • Bagwell CB, Adams EG. Fluorescence spectral overlap compensation for any numbers of flow cytometry parameters. Ann NY Acad Sci 1993;677:167-184.
    • (1993) Ann NY Acad Sci , vol.677 , pp. 167-184
    • Bagwell, C.B.1    Adams, E.G.2
  • 13
    • 0022820256 scopus 로고
    • Dual-laser, differential fluorescence correction method for reducing cellular background autofluorescence
    • Steinkamp JA, Stewart CC. Dual-laser, differential fluorescence correction method for reducing cellular background autofluorescence Cytometry 1986;7:566-574.
    • (1986) Cytometry , vol.7 , pp. 566-574
    • Steinkamp, J.A.1    Stewart, C.C.2
  • 14
    • 0021918010 scopus 로고
    • Pontamine sky blue: A counterstain for background autofluorescence in fluorescence and immunofluorescence histochemistry
    • Cowen T, Haven AJ, Burnstock G. Pontamine sky blue: a counterstain for background autofluorescence in fluorescence and immunofluorescence histochemistry. Histochem 1985;82:205-208.
    • (1985) Histochem , vol.82 , pp. 205-208
    • Cowen, T.1    Haven, A.J.2    Burnstock, G.3
  • 15
    • 0022650417 scopus 로고
    • Translocation of particles to the tracheobronchial lymph nodes after lung deposition: Kinetics and particle-cell relationships
    • Lehnert BE, Valdez YE, Stewart CC. Translocation of particles to the tracheobronchial lymph nodes after lung deposition: kinetics and particle-cell relationships. Exptl Lung Res 1986;10:245-266.
    • (1986) Exptl Lung Res , vol.10 , pp. 245-266
    • Lehnert, B.E.1    Valdez, Y.E.2    Stewart, C.C.3
  • 16
    • 0023724955 scopus 로고
    • Use of allophyocyanin allows quantitative description by flow cytometry of alveolar macrophage surface antigens present in low numbers of cells
    • Fuchs HJ, McDowell J, Shellito JE. Use of allophyocyanin allows quantitative description by flow cytometry of alveolar macrophage surface antigens present in low numbers of cells. Am Rev Respir Dis 1988;138:1124-1128.
    • (1988) Am Rev Respir Dis , vol.138 , pp. 1124-1128
    • Fuchs, H.J.1    McDowell, J.2    Shellito, J.E.3
  • 17
    • 0023696898 scopus 로고
    • Correction of cellular autofluorescence in flow cytometry by mathematical modeling of cellular autofluorescence
    • Corsetti JP, Sotirchos SV, Cox C, Cowles JW, Leary JF, Blumburg N. Correction of cellular autofluorescence in flow cytometry by mathematical modeling of cellular autofluorescence. Cytometry 1988;9:539-547.
    • (1988) Cytometry , vol.9 , pp. 539-547
    • Corsetti, J.P.1    Sotirchos, S.V.2    Cox, C.3    Cowles, J.W.4    Leary, J.F.5    Blumburg, N.6
  • 18
    • 0028261873 scopus 로고
    • Evaluation of the number of positive cells from cytometric immunoassays by mathematical modeling of cellular autofluorescence
    • Lampariello F. Evaluation of the number of positive cells from cytometric immunoassays by mathematical modeling of cellular autofluorescence. Cytometry 1994;15:294-301.
    • (1994) Cytometry , vol.15 , pp. 294-301
    • Lampariello, F.1
  • 19
    • 0014210820 scopus 로고
    • Fluorescence decay times: Proteins, coenzymes, and other compounds in water
    • Chen RF, Vurek GG, Alexander N. Fluorescence decay times: proteins, coenzymes, and other compounds in water. Science 1967;156: 949-951.
    • (1967) Science , vol.156 , pp. 949-951
    • Chen, R.F.1    Vurek, G.G.2    Alexander, N.3
  • 20
    • 84981857769 scopus 로고
    • Measurements of subnanosecond fluorescence lifetimes with a cross-correlation phase fluorometer
    • Spencer RD, Weber G. Measurements of subnanosecond fluorescence lifetimes with a cross-correlation phase fluorometer. Ann NY Acad Sci 1969;158:361-376.
    • (1969) Ann NY Acad Sci , vol.158 , pp. 361-376
    • Spencer, R.D.1    Weber, G.2
  • 21
    • 0029843925 scopus 로고    scopus 로고
    • Two-photon excited lifetime imaging of autofluorescence in cells during UVA and NIR photostress
    • König K, So PTC, Mantulin WW, Tromberg J, Gratton E. Two-photon excited lifetime imaging of autofluorescence in cells during UVA and NIR photostress. J Microscopy 1996;183:197-204.
    • (1996) J Microscopy , vol.183 , pp. 197-204
    • König, K.1    So, P.T.C.2    Mantulin, W.W.3    Tromberg, J.4    Gratton, E.5
  • 22
    • 0028263689 scopus 로고
    • Use of fluorescent europium chelates as labels in microscopy allows glutaraldehyde fixation and permanent mounting and leads to reduced autofluorescence and good long-term stability
    • Sevéus L, Väisälä M, Hemmilä I, Kojola H, Roomans GM, Soini E. Use of fluorescent europium chelates as labels in microscopy allows glutaraldehyde fixation and permanent mounting and leads to reduced autofluorescence and good long-term stability. Micros Res Tech 1994;28:149-154.
    • (1994) Micros Res Tech , vol.28 , pp. 149-154
    • Sevéus, L.1    Väisälä, M.2    Hemmilä, I.3    Kojola, H.4    Roomans, G.M.5    Soini, E.6
  • 23
    • 0028240860 scopus 로고
    • Time-resolved flow cytometry for the measurement of lanthanide chelate fluorescence: II. Instrument design and experimental results
    • Condrau MA, Schwendener RA, Zimmermann M, Muser MH, Graf U, Niederer P, Anliker M. Time-resolved flow cytometry for the measurement of lanthanide chelate fluorescence: II. Instrument design and experimental results. Cytometry 1994;16:195-205.
    • (1994) Cytometry , vol.16 , pp. 195-205
    • Condrau, M.A.1    Schwendener, R.A.2    Zimmermann, M.3    Muser, M.H.4    Graf, U.5    Niederer, P.6    Anliker, M.7
  • 24
    • 0000391185 scopus 로고
    • Flow cytometer for resolving signals from heterogeneous fluorescence emissions and quantifying lifetime in fluorochrome-labeled cells/particles by phase-sensitive detection
    • Steinkamp JA, Yoshida TM, Martin JC. Flow cytometer for resolving signals from heterogeneous fluorescence emissions and quantifying lifetime in fluorochrome-labeled cells/particles by phase-sensitive detection. Rev Sci Instrum 1993;64:3440-3450.
    • (1993) Rev Sci Instrum , vol.64 , pp. 3440-3450
    • Steinkamp, J.A.1    Yoshida, T.M.2    Martin, J.C.3
  • 25
    • 0001230156 scopus 로고
    • Phase sensitive detection as a means to recover signals buried in noise
    • Blair DP, Sydenham PH. Phase sensitive detection as a means to recover signals buried in noise. J Phys E Sci Instrum 1975;8:621-627.
    • (1975) J Phys E Sci Instrum , vol.8 , pp. 621-627
    • Blair, D.P.1    Sydenham, P.H.2
  • 26
    • 0001346702 scopus 로고
    • Fluorometric method for individual recording of spectra in systems containing two types of luminescent centers
    • Veselova TV, Cherkasov AS, Shirokov VI. Fluorometric method for individual recording of spectra in systems containing two types of luminescent centers. Opt Spect 1970;29:617-618.
    • (1970) Opt Spect , vol.29 , pp. 617-618
    • Veselova, T.V.1    Cherkasov, A.S.2    Shirokov, V.I.3
  • 27
    • 0020113530 scopus 로고
    • Advances in lock-in amplifiers
    • Meade ML Advances in lock-in amplifiers. J Phys E Sci Instrum 1982;15:395-403.
    • (1982) J Phys E Sci Instrum , vol.15 , pp. 395-403
    • Meade, M.L.1
  • 28
    • 0019479222 scopus 로고
    • Modular electronics for flow cytometry and sorting: The LACEL system
    • Hiehert RD, Jett JH, Salzman GC. Modular electronics for flow cytometry and sorting: the LACEL system. Cytometry 1981;1:337-341.
    • (1981) Cytometry , vol.1 , pp. 337-341
    • Hiehert, R.D.1    Jett, J.H.2    Salzman, G.C.3
  • 29
    • 0029727380 scopus 로고    scopus 로고
    • Fluorescence lifetime as a new parameter in analytical cytology measurements
    • Steinkamp JA, Deka C, Lehnert BE, Crissman HA. Fluorescence lifetime as a new parameter in analytical cytology measurements Proc SPIE 1996;2678:221-230.
    • (1996) Proc SPIE , vol.2678 , pp. 221-230
    • Steinkamp, J.A.1    Deka, C.2    Lehnert, B.E.3    Crissman, H.A.4
  • 30
    • 0029854845 scopus 로고    scopus 로고
    • Analysis of fluorescence lifetime and quenching of FITC-conjugated antibodies on cells by phase-sensitive flow cytometry
    • Deka C, Lehnert BE, Lehnert NM, Jones GM, Sklar LA, Steinkamp JA. Analysis of fluorescence lifetime and quenching of FITC-conjugated antibodies on cells by phase-sensitive flow cytometry. Cytometry 1996;25:271-279.
    • (1996) Cytometry , vol.25 , pp. 271-279
    • Deka, C.1    Lehnert, B.E.2    Lehnert, N.M.3    Jones, G.M.4    Sklar, L.A.5    Steinkamp, J.A.6
  • 31
    • 0017728119 scopus 로고
    • Two-color immunofluorescence using a fluorescence activated cell-sorter
    • Loken MR, Parks DR, Herzenberg LA. Two-color immunofluorescence using a fluorescence activated cell-sorter. J Histochem Cytochem 1977;25:899-907.
    • (1977) J Histochem Cytochem , vol.25 , pp. 899-907
    • Loken, M.R.1    Parks, D.R.2    Herzenberg, L.A.3
  • 32
    • 0032919615 scopus 로고    scopus 로고
    • Simultaneous analysis of relative DNA and glutathione content in viable cells by phase-resolved flow cytometry
    • Keij JF, Bell-Prince C, Steinkamp JA. Simultaneous analysis of relative DNA and glutathione content in viable cells by phase-resolved flow cytometry. Cytometry 1999; 5:48-54.
    • (1999) Cytometry , vol.5 , pp. 48-54
    • Keij, J.F.1    Bell-Prince, C.2    Steinkamp, J.A.3
  • 33
    • 0032809173 scopus 로고    scopus 로고
    • Discrimination of damaged/ dead cells by propidium iodide uptake in immunoflluorescently-labeled populations analyzed by phase-sensitive flow cytometry
    • Steinkamp JA, Lehnert BE, Lehnert NM. Discrimination of damaged/ dead cells by propidium iodide uptake in immunoflluorescently-labeled populations analyzed by phase-sensitive flow cytometry. J Immunol Meth 1999;226:59-70.
    • (1999) J Immunol Meth , vol.226 , pp. 59-70
    • Steinkamp, J.A.1    Lehnert, B.E.2    Lehnert, N.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.