메뉴 건너뛰기




Volumn 31, Issue 3, 1999, Pages 313-319

The use of polytetrafluoroethylene (Gore-Tex) grafts in reconstruction of the urinary bladder

Author keywords

[No Author keywords available]

Indexed keywords

POLITEF;

EID: 0033451770     PISSN: 03011623     EISSN: None     Source Type: Journal    
DOI: 10.1023/A:1007117917974     Document Type: Article
Times cited : (3)

References (16)
  • 1
    • 0025023862 scopus 로고
    • Evaluation of Gore-Tex graft material in the repair of right ventricular outflow tract detect
    • Ehler, W. J., Cissik, J. H., Smith, V. C., Hubbard, G. B.: Evaluation of Gore-Tex graft material in the repair of right ventricular outflow tract detect. J. Invest. Surg , 3, 119 (1990).
    • (1990) J. Invest. Surg , vol.3 , pp. 119
    • Ehler, W.J.1    Cissik, J.H.2    Smith, V.C.3    Hubbard, G.B.4
  • 2
    • 0028123614 scopus 로고
    • Clinicopathologic study of Gore-Tex patch graft in corneoscleral surgery
    • Huang, W. J., Hu, F. R., Chang, S. W.: Clinicopathologic study of Gore-Tex patch graft in corneoscleral surgery. Cornea, 13, 82 (1994).
    • (1994) Cornea , vol.13 , pp. 82
    • Huang, W.J.1    Hu, F.R.2    Chang, S.W.3
  • 3
    • 0028265614 scopus 로고
    • Vascularized muscle flaps for life-threatening mediastinal wounds in children
    • Backer, C. L., Pensler, J. M., Tobin, G. R., Mavroudis, C.: Vascularized muscle flaps for life-threatening mediastinal wounds in children. Ann. Thorac. Surg , 57, 797 (1994).
    • (1994) Ann. Thorac. Surg , vol.57 , pp. 797
    • Backer, C.L.1    Pensler, J.M.2    Tobin, G.R.3    Mavroudis, C.4
  • 5
    • 0025191531 scopus 로고
    • Performance of a longitudinally compliant PTFE vascular prosthesis in an ovine A-V fistula model
    • Kenney, D. A. et al.: Performance of a longitudinally compliant PTFE vascular prosthesis in an ovine A-V fistula model. ASAIO Trans., 36, M761-3 (1990).
    • (1990) ASAIO Trans. , vol.36
    • Kenney, D.A.1
  • 6
    • 0026346636 scopus 로고
    • Early cannulation of plasma TFE and GoreTex grafts for hemodialysis: A prospective randomized study
    • Jaffers, G., Angstadt, J. D., Bowman, J. S.: Early cannulation of plasma TFE and GoreTex grafts for hemodialysis: A prospective randomized study. Am. J. Nephrol., 11, 369 (1991).
    • (1991) Am. J. Nephrol. , vol.11 , pp. 369
    • Jaffers, G.1    Angstadt, J.D.2    Bowman, J.S.3
  • 7
    • 0026950412 scopus 로고
    • The "Mainz pouch" technique (bladder augmentation with ileum and cecum) for bladder augmentation, bladder substitution, and continent urinary diversion
    • Fisch, M., Wammack, R., Thüroff, J., Hohenfellner, R.: The "Mainz pouch" technique (bladder augmentation with ileum and cecum) for bladder augmentation, bladder substitution, and continent urinary diversion. Arch. Esp. Urol., 45, 903 (1992).
    • (1992) Arch. Esp. Urol. , vol.45 , pp. 903
    • Fisch, M.1    Wammack, R.2    Thüroff, J.3    Hohenfellner, R.4
  • 8
    • 0029020853 scopus 로고
    • Urinary pH and urea concentration correlate to the bacterial colonization rate in gastric, colonic, ileal and myoperitoneal bladder augmentation
    • Lauvetz, R. W., Monda, J. M., Kramer, S. A., Husmann, D. A.: Urinary pH and urea concentration correlate to the bacterial colonization rate in gastric, colonic, ileal and myoperitoneal bladder augmentation. J. Urol., 154, 2, 899 (1995).
    • (1995) J. Urol. , vol.154 , Issue.2 , pp. 899
    • Lauvetz, R.W.1    Monda, J.M.2    Kramer, S.A.3    Husmann, D.A.4
  • 9
    • 0000899087 scopus 로고
    • Die Wiederherstellung der Harnblase
    • Tizzoni, G., Foggi, A.: Die Wiederherstellung der Harnblase. Zentralbl. Chir., 15, 921 (1888).
    • (1888) Zentralbl. Chir. , vol.15 , pp. 921
    • Tizzoni, G.1    Foggi, A.2
  • 10
    • 0015379779 scopus 로고
    • Energy balance of voiding after cecal cystoplasty
    • Gleason, D. M., Gittes, R. F., Bottaccini, M. R.: Energy balance of voiding after cecal cystoplasty. J. Urol., 108, 259 (1972).
    • (1972) J. Urol. , vol.108 , pp. 259
    • Gleason, D.M.1    Gittes, R.F.2    Bottaccini, M.R.3
  • 11
    • 0023812106 scopus 로고
    • Perforation of the augmented bladder in patients undergoing clean intermittent catheterization
    • Elder, J. S., Snyder, H. M., Hulbert, W. C., Duckett, J. W.: Perforation of the augmented bladder in patients undergoing clean intermittent catheterization. J. Urol., 140, 1159 (1988).
    • (1988) J. Urol. , vol.140 , pp. 1159
    • Elder, J.S.1    Snyder, H.M.2    Hulbert, W.C.3    Duckett, J.W.4
  • 14
    • 0018082069 scopus 로고
    • Alloplastic replacement of the canine ureter by expanded polytetrafluoroethylene (Gore-Tex) grafts
    • Drekion, K., Liobelenz, J.: Alloplastic replacement of the canine ureter by expanded polytetrafluoroethylene (Gore-Tex) grafts. Eur. Urol., 4, 379 (1978).
    • (1978) Eur. Urol. , vol.4 , pp. 379
    • Drekion, K.1    Liobelenz, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.