메뉴 건너뛰기




Volumn 21, Issue 5, 1999, Pages 347-351

Performance characteristics of blast flagging on the Cell Dyn 4000 haematology analyser

Author keywords

Blast; Blood smear; Cell Dyn 4000; Confidence fraction; Haematology analyser

Indexed keywords

ARTICLE; AUTOANALYSIS; BLOOD SMEAR; CLINICAL LABORATORY; DIAGNOSTIC ACCURACY; HEMATOPOIETIC SYSTEM TUMOR; HUMAN; HUMAN CELL; LEUKOCYTE COUNT; PRIORITY JOURNAL; PROGNOSIS;

EID: 0033429492     PISSN: 01419854     EISSN: None     Source Type: Journal    
DOI: 10.1046/j.1365-2257.1999.00229.x     Document Type: Article
Times cited : (8)

References (6)
  • 1
    • 0030931947 scopus 로고    scopus 로고
    • An evaluation of the differential from the Abbott CD 3500 in a population of patients with haematological abnormalities
    • Iles-Mann J. & Henniker J. (1997) An evaluation of the differential from the Abbott CD 3500 in a population of patients with haematological abnormalities. Clinical and Laboratory Haematology 19, 191-196.
    • (1997) Clinical and Laboratory Haematology , vol.19 , pp. 191-196
    • Iles-Mann, J.1    Henniker, J.2
  • 2
    • 0002718299 scopus 로고    scopus 로고
    • CELL DYN 4000: Utility within the core laboratory structure and preliminary comparison of its expanded differential with the 400-cell manual differential count
    • Jones R.G., Faust A., Glazier J., Matthews R. & Potter B. (1998) CELL DYN 4000: Utility within the core laboratory structure and preliminary comparison of its expanded differential with the 400-cell manual differential count. Laboratory Hematology 4, 34-44.
    • (1998) Laboratory Hematology , vol.4 , pp. 34-44
    • Jones, R.G.1    Faust, A.2    Glazier, J.3    Matthews, R.4    Potter, B.5
  • 4
    • 0024353153 scopus 로고
    • Identification of blast cells in the peripheral blood of patients with acute leukemia using the Technicon H-1
    • Kline A., Bird A., Adams L., Wale C., Edwards F. & Perreira E. (1989) Identification of blast cells in the peripheral blood of patients with acute leukemia using the Technicon H-1. Clinical and Laboratory Haematology 11, 111-116.
    • (1989) Clinical and Laboratory Haematology , vol.11 , pp. 111-116
    • Kline, A.1    Bird, A.2    Adams, L.3    Wale, C.4    Edwards, F.5    Perreira, E.6
  • 6
    • 17144463591 scopus 로고    scopus 로고
    • Automated five-part white blood cell differential counts. Efficiency of software generated white blood cell suspect flags of the haematology analysers Sysmex SE-9000, Sysmex NE-8000, and Coulter STKS
    • Thalhammer-Scherrer R., Knobl P., Korninger L. & Schwarzinger I. (1997) Automated five-part white blood cell differential counts. Efficiency of software generated white blood cell suspect flags of the haematology analysers Sysmex SE-9000, Sysmex NE-8000, and Coulter STKS. Archives of Pathology and Laboratory Medicine 121, 573-577.
    • (1997) Archives of Pathology and Laboratory Medicine , vol.121 , pp. 573-577
    • Thalhammer-Scherrer, R.1    Knobl, P.2    Korninger, L.3    Schwarzinger, I.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.