메뉴 건너뛰기




Volumn 83, Issue 1-3, 1999, Pages 225-237

Suppression of vortex-excited vibration of tall buildings using tuned liquid dampers

Author keywords

Tall buildings; Tuned liquid dampers; Vortex vibration; Wind tunnel tests

Indexed keywords

DAMPING; OPTIMIZATION; TALL BUILDINGS; VIBRATION CONTROL; VORTEX FLOW; WIND TUNNELS;

EID: 0033405507     PISSN: 01676105     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0167-6105(99)00074-4     Document Type: Article
Times cited : (57)

References (8)
  • 1
    • 0027869276 scopus 로고
    • Vibration control by multiple tuned liquid dampers (MTLDs)
    • Y. Fujino, L.M. Sun, Vibration control by multiple tuned liquid dampers (MTLDs), J. Struct. Eng. ASCE 119 (12) (1993) 3482-3502.
    • (1993) J. Struct. Eng. ASCE , vol.119 , Issue.12 , pp. 3482-3502
    • Fujino, Y.1    Sun, L.M.2
  • 2
    • 0024090938 scopus 로고
    • Parametric studies on tuned liquid damper (TLD) using circular containers by free-oscillation experiments
    • Y. Fujino, B.M. Pacheco, P. Chaiseri, L.M. Sun, Parametric studies on tuned liquid damper (TLD) using circular containers by free-oscillation experiments, Struct. Eng. Earthquake Eng. JSCE 5 (2) (1988) 177-187.
    • (1988) Struct. Eng. Earthquake Eng. JSCE , vol.5 , Issue.2 , pp. 177-187
    • Fujino, Y.1    Pacheco, B.M.2    Chaiseri, P.3    Sun, L.M.4
  • 3
    • 0024749917 scopus 로고
    • Interaction of tuned liquid damper (TLD) and structure-theory, experimental verification and application
    • P. Chaiseri, Y. Fujino, B.M. Pacheco, L.M. Sun, Interaction of tuned liquid damper (TLD) and structure-theory, experimental verification and application, Struct. Eng. Earthquake Eng. JSCE 6 (2) (1989) 103-112.
    • (1989) Struct. Eng. Earthquake Eng. JSCE , vol.6 , Issue.2 , pp. 103-112
    • Chaiseri, P.1    Fujino, Y.2    Pacheco, B.M.3    Sun, L.M.4
  • 5
    • 0026933601 scopus 로고
    • Suppression of wind-induced vibration by dynamic dampers in tower-like structures
    • T. Ueda, R. Nakagaki, K. Koshida, Suppression of wind-induced vibration by dynamic dampers in tower-like structures, J. Wind Eng. Ind. Aerodyn. 41-44 (1992) 1907-1918.
    • (1992) J. Wind Eng. Ind. Aerodyn. , vol.41-44 , pp. 1907-1918
    • Ueda, T.1    Nakagaki, R.2    Koshida, K.3
  • 6
    • 0026933589 scopus 로고
    • Suppression of wind-induced vibration of a tall building using tuned liquid damper
    • T. Wakahara, T. Ohyama, K. Fujii, Suppression of wind-induced vibration of a tall building using tuned liquid damper, J. Wind Eng. Ind. Aerodyn. 41-44 (1992) 1895-1906.
    • (1992) J. Wind Eng. Ind. Aerodyn. , vol.41-44 , pp. 1895-1906
    • Wakahara, T.1    Ohyama, T.2    Fujii, K.3
  • 7
    • 0027686914 scopus 로고
    • Design formulas for tuned mass dampers based on a perturbation technique
    • Y. Fujino, M. Abé, Design formulas for tuned mass dampers based on a perturbation technique, Earthquake Eng. Struct. Dyn. 22 (1993) 833-854.
    • (1993) Earthquake Eng. Struct. Dyn. , vol.22 , pp. 833-854
    • Fujino, Y.1    Abé, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.