메뉴 건너뛰기




Volumn 13, Issue 12, 1999, Pages 931-936

Rapid and sensitive galactose oxidase-peroxidase biosensor for galactose detection with prolonged stability

Author keywords

Biosensor; Ferrocene; Galactose oxidase peroxidase; Graphite electrode; Stabilisation

Indexed keywords

ADSORPTION; BORIC ACID; BUFFER; CHELATING AGENT; DETECTION; DEXTRAN; ELECTRODE; ENZYMIC BIOSENSOR; FERROCENE; GALACTOSE OXIDASE; GALACTOSE; INOSITOL; PH;

EID: 0033401165     PISSN: 0951208X     EISSN: None     Source Type: Journal    
DOI: 10.1023/A:1008966413722     Document Type: Article
Times cited : (27)

References (13)
  • 2
    • 0029058443 scopus 로고
    • Development of amperometric biosensors based on the immobilization of enzymes in polymer film electrogenerated from a series of amphiphilic pyrrole derivatives
    • Coche-Guerente L, Cosnier S, Innocent C, Mailley P (1995) Development of amperometric biosensors based on the immobilization of enzymes in polymer film electrogenerated from a series of amphiphilic pyrrole derivatives. Anal. Chim. Acta 311: 23-30.
    • (1995) Anal. Chim. Acta , vol.311 , pp. 23-30
    • Coche-Guerente, L.1    Cosnier, S.2    Innocent, C.3    Mailley, P.4
  • 3
    • 84987476983 scopus 로고
    • Peroxidase-ferrocene modified carbon paste electrode as an amperometric sensor for the hydrogen peroxide assay
    • Domínguez Sánchez P, Ordieres AJM, García AC, Blanco PT (1991) Peroxidase-ferrocene modified carbon paste electrode as an amperometric sensor for the hydrogen peroxide assay. Electroanalysis 3: 281-285.
    • (1991) Electroanalysis , vol.3 , pp. 281-285
    • Domínguez Sánchez, P.1    Ordieres, A.J.M.2    García, A.C.3    Blanco, P.T.4
  • 4
    • 0027325001 scopus 로고
    • Preservation of shelf life of enzyme based analytical system using a combination of sugars, sugar alcohols and cationic polymers or zinc ions
    • Gibson TD, Hulbert JN, Woodward JR (1993) Preservation of shelf life of enzyme based analytical system using a combination of sugars, sugar alcohols and cationic polymers or zinc ions. Anal. Chim. Acta 219: 185-192.
    • (1993) Anal. Chim. Acta , vol.219 , pp. 185-192
    • Gibson, T.D.1    Hulbert, J.N.2    Woodward, J.R.3
  • 5
    • 33646276645 scopus 로고
    • Ketose sugars from aldose sugars. US Patent 4 273 922
    • Hicks KB (1981) Ketose sugars from aldose sugars. US Patent 4 273 922.
    • (1981)
    • Hicks, K.B.1
  • 6
    • 0024498277 scopus 로고
    • A post-column coimmobilized galactose oxidase/peroxidase reactor for fluorometric detection of saccharides in a liquid Chromatographic system
    • Kiba N, Shitara K, Furusawa M (1989) A post-column coimmobilized galactose oxidase/peroxidase reactor for fluorometric detection of saccharides in a liquid Chromatographic system. J. Chromatogr. 463: 183-184
    • (1989) J. Chromatogr. , vol.463 , pp. 183-184
    • Kiba, N.1    Shitara, K.2    Furusawa, M.3
  • 7
    • 0026077569 scopus 로고
    • Design and optimization of a flow-injection system for enzymatic determination of galactose
    • Kurtz KS, Crouch SR (1991) Design and optimization of a flow-injection system for enzymatic determination of galactose. Anal. Chim. Acta 254: 201-208.
    • (1991) Anal. Chim. Acta , vol.254 , pp. 201-208
    • Kurtz, K.S.1    Crouch, S.R.2
  • 8
    • 0026484812 scopus 로고
    • Amperometric glucose biosensor with extended concentration range utilizing complexation effect of borate
    • Macholán L, Skládal P, Boháèková I, Krejčí J (1992) Amperometric glucose biosensor with extended concentration range utilizing complexation effect of borate. Biosens. Bioelectron. 7: 593-598.
    • (1992) Biosens. Bioelectron. , vol.7 , pp. 593-598
    • Macholán, L.1    Skládal, P.2    Boháèková, I.3    Krejčí, J.4
  • 9
    • 0033463080 scopus 로고    scopus 로고
    • Simultaneous determination of glucose and galactose in dairy products by two parallel amperometric biosensors
    • Mannino S, Cosio MS, Buratti S (1999) Simultaneous determination of glucose and galactose in dairy products by two parallel amperometric biosensors. Ital. J. Food Sci. 11: 57-65
    • (1999) Ital. J. Food Sci. , vol.11 , pp. 57-65
    • Mannino, S.1    Cosio, M.S.2    Buratti, S.3
  • 11
    • 0029765767 scopus 로고    scopus 로고
    • Application of biosensor for monitoring galactose content
    • Szabó EE, Adányi N, Váradi M (1996) Application of biosensor for monitoring galactose content. Biosens. Bioelectron. 11: 1051-1058.
    • (1996) Biosens. Bioelectron. , vol.11 , pp. 1051-1058
    • Szabó, E.E.1    Adányi, N.2    Váradi, M.3
  • 12
    • 0001104224 scopus 로고    scopus 로고
    • Critical comparison of metallized and mediator-based carbon paste glucose biosensors
    • Wang J, Chen L, Liu J (1997) Critical comparison of metallized and mediator-based carbon paste glucose biosensors. Electroanalysis 9: 298-301.
    • (1997) Electroanalysis , vol.9 , pp. 298-301
    • Wang, J.1    Chen, L.2    Liu, J.3
  • 13
    • 0032499626 scopus 로고    scopus 로고
    • Kinetic isotope effects as probes of the mechanism of galactose oxidase
    • Whittaker MM, Ballou DP, Whittaker JW (1998) Kinetic isotope effects as probes of the mechanism of galactose oxidase. Biochemistry 37: 8426-8436.
    • (1998) Biochemistry , vol.37 , pp. 8426-8436
    • Whittaker, M.M.1    Ballou, D.P.2    Whittaker, J.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.