메뉴 건너뛰기




Volumn 27, Issue 12, 1999, Pages 2694-2697

Comparison of two semicontinuous cardiac output pulmonary artery catheters after valvular surgery

Author keywords

Bolus cardiac output; Cardiopulmonary bypass; Heart; Hemodynamics; Hypothermic; Monitoring; Physiologic; Postoperative care unit; Pulmonary artery catheters; Semicontinuous cardiac output; Thermodilution; Valvular surgery

Indexed keywords

ADULT; AGED; AORTA VALVE; ARTERY CATHETER; ARTICLE; CARDIOPULMONARY BYPASS; CLINICAL ARTICLE; CLINICAL TRIAL; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; DEVICE; FEMALE; HEART OUTPUT; HEART VALVE SURGERY; HEMODYNAMIC MONITORING; HUMAN; MALE; MEAN ARTERIAL PRESSURE; MITRAL VALVE; PRIORITY JOURNAL; PULMONARY ARTERY; RANDOMIZED CONTROLLED TRIAL; SINUS RHYTHM;

EID: 0033396426     PISSN: 00903493     EISSN: None     Source Type: Journal    
DOI: 10.1097/00003246-199912000-00015     Document Type: Article
Times cited : (12)

References (19)
  • 1
    • 0015041424 scopus 로고
    • A new technique for measurement of cardiac output by thermodilution in man
    • 1. Ganz W, Donoso R, Marcus HS, et al: A new technique for measurement of cardiac output by thermodilution in man. Am J Cardiol 1971; 27:392-396
    • (1971) Am J Cardiol , vol.27 , pp. 392-396
    • Ganz, W.1    Donoso, R.2    Marcus, H.S.3
  • 2
    • 0025130516 scopus 로고
    • Continuous measurement of cardiac output with the use of stochastic system identification techniques
    • 2. Yelderman ML: Continuous measurement of cardiac output with the use of stochastic system identification techniques. J Clin Monit 1990; 6:322-332
    • (1990) J Clin Monit , vol.6 , pp. 322-332
    • Yelderman, M.L.1
  • 3
    • 0026695419 scopus 로고
    • Continuous thermodilution cardiac output measurements in intensive care unit patients
    • 3. Yelderman ML, Ramsay MA, Quinn MD, et al: Continuous thermodilution cardiac output measurements in intensive care unit patients. J Cardiothorac Vasc Anesth 1992; 6:270-274
    • (1992) J Cardiothorac Vasc Anesth , vol.6 , pp. 270-274
    • Yelderman, M.L.1    Ramsay, M.A.2    Quinn, M.D.3
  • 4
    • 0019351431 scopus 로고
    • Effect of hypothermia, hemodilution, and pump oxygenation on organ water content, blood flow and oxygen delivery, and renal function
    • 4. Utley JR, Wachtel C, Cain RB, et al: Effect of hypothermia, hemodilution, and pump oxygenation on organ water content, blood flow and oxygen delivery, and renal function. Ann Thorac Surg 1981; 31:121-133
    • (1981) Ann Thorac Surg , vol.31 , pp. 121-133
    • Utley, J.R.1    Wachtel, C.2    Cain, R.B.3
  • 5
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • 5. Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; i:307-310
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 6
    • 0025166460 scopus 로고
    • Non invasive versus invasive assessment of cardiac output after cardiac surgery: Clinical validation
    • 6. Spahn DR, Schmid ER, Tornic M, et al: Non invasive versus invasive assessment of cardiac output after cardiac surgery: Clinical validation. J Cardiothorac Vasc Anesth 1990; 4:46-59
    • (1990) J Cardiothorac Vasc Anesth , vol.4 , pp. 46-59
    • Spahn, D.R.1    Schmid, E.R.2    Tornic, M.3
  • 7
    • 0028355287 scopus 로고
    • Cardiac output by transesophageal echocardiography using continuous-wave Doppler across the aortic valve
    • 7. Darmon PL, Hillel Z, Mogtader A, et al: Cardiac output by transesophageal echocardiography using continuous-wave Doppler across the aortic valve. Anesthesiology 1994; 80: 796-805
    • (1994) Anesthesiology , vol.80 , pp. 796-805
    • Darmon, P.L.1    Hillel, Z.2    Mogtader, A.3
  • 8
    • 0029154767 scopus 로고
    • Continuous thermodilution cardiac output agreement with Fick and bolus thermodilution methods
    • 8. Thrush D, Dows JB, Smith RA: Continuous thermodilution cardiac output agreement with Fick and bolus thermodilution methods. J Cardiothorac Vasc Anesth 1995; 9:399-404
    • (1995) J Cardiothorac Vasc Anesth , vol.9 , pp. 399-404
    • Thrush, D.1    Dows, J.B.2    Smith, R.A.3
  • 9
    • 0028784190 scopus 로고
    • Comparison between oxygen consumption calculated by Fick's principle using a continuous thermodilution technique and measured by indirect calorimetry
    • 9. Bizouarn P, Blanloeil Y, Pinaud M: Comparison between oxygen consumption calculated by Fick's principle using a continuous thermodilution technique and measured by indirect calorimetry. Br J Anaesth 1995; 75: 719-723
    • (1995) Br J Anaesth , vol.75 , pp. 719-723
    • Bizouarn, P.1    Blanloeil, Y.2    Pinaud, M.3
  • 10
    • 0001157673 scopus 로고
    • Comparison of continuous versus manual bolus cardiac output following hemodynamic alterations in a porcine model
    • 10. Ryan MK, Fan YP, Lee TS, et al: Comparison of continuous versus manual bolus cardiac output following hemodynamic alterations in a porcine model. Abstr. Anesthesiology 1993; 79:A469
    • (1993) Anesthesiology , vol.79
    • Ryan, M.K.1    Fan, Y.P.2    Lee, T.S.3
  • 11
    • 1842300435 scopus 로고    scopus 로고
    • Continuous versus intermittent thermodilution cardiac output measurement during orthotopic liver transplantation
    • 11. Böttinger BW, Sinner B, Motsch J, et al: Continuous versus intermittent thermodilution cardiac output measurement during orthotopic liver transplantation. Anaesthesia 1997; 52:207-214
    • (1997) Anaesthesia , vol.52 , pp. 207-214
    • Böttinger, B.W.1    Sinner, B.2    Motsch, J.3
  • 12
    • 0021076099 scopus 로고
    • Cardiac output by thermodilution technique: Effects of injectate's volume and temperature on accuracy and reproducibility in the critically ill patient
    • 12. Elkayam U, Berkley R, Azen S, et al: Cardiac output by thermodilution technique: Effects of injectate's volume and temperature on accuracy and reproducibility in the critically ill patient. Chest 1983; 84:418-422
    • (1983) Chest , vol.84 , pp. 418-422
    • Elkayam, U.1    Berkley, R.2    Azen, S.3
  • 13
    • 0020202085 scopus 로고
    • Effects of mechanical ventilation on the measurement of cardiac output by thermodilution
    • 13. Snyder JV, Powner DJ: Effects of mechanical ventilation on the measurement of cardiac output by thermodilution. Crit Care Med 1982; 10:677-682
    • (1982) Crit Care Med , vol.10 , pp. 677-682
    • Snyder, J.V.1    Powner, D.J.2
  • 14
    • 0024563766 scopus 로고
    • Under estimation of cardiac output by thermodilution in patients with tricuspid regurgitation
    • 14. Cigarroa RG, Lange RA, Williams RH, et al: Under estimation of cardiac output by thermodilution in patients with tricuspid regurgitation. Am J Med 1989; 86:417-420
    • (1989) Am J Med , vol.86 , pp. 417-420
    • Cigarroa, R.G.1    Lange, R.A.2    Williams, R.H.3
  • 15
    • 0027447134 scopus 로고
    • Errors in the measurement of cardiac output by thermodilution
    • 15. Nishikawa T, Dohi S: Errors in the measurement of cardiac output by thermodilution. Can J Anaesth 1993; 40:142-153
    • (1993) Can J Anaesth , vol.40 , pp. 142-153
    • Nishikawa, T.1    Dohi, S.2
  • 16
    • 0027137477 scopus 로고
    • Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass
    • 16. Latson TW, Whitten CW, O'Flaherty D: Ventilation, thermal noise, and errors in cardiac output measurements after cardiopulmonary bypass. Anesthesiology 1993; 79:1233-1243
    • (1993) Anesthesiology , vol.79 , pp. 1233-1243
    • Latson, T.W.1    Whitten, C.W.2    O'Flaherty, D.3
  • 17
    • 0029168048 scopus 로고
    • Continuous versus intermittent cardiac output measurement in cardiac surgical patients undergoing hypothermic cardio-pulmonary bypass
    • 17. Böttinger BW, Rauch H, Böhrer H, et al: Continuous versus intermittent cardiac output measurement in cardiac surgical patients undergoing hypothermic cardio-pulmonary bypass. J Cardiothorac Vasc Anesth 1995; 9:405-411
    • (1995) J Cardiothorac Vasc Anesth , vol.9 , pp. 405-411
    • Böttinger, B.W.1    Rauch, H.2    Böhrer, H.3
  • 18
    • 0027938298 scopus 로고
    • Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient?
    • 18. Boldt J, Menges T, Wollbruck M, et al: Is continuous cardiac output measurement using thermodilution reliable in the critically ill patient? Crit Care Med 1994; 22: 1913-1918
    • (1994) Crit Care Med , vol.22 , pp. 1913-1918
    • Boldt, J.1    Menges, T.2    Wollbruck, M.3
  • 19
    • 4243327302 scopus 로고    scopus 로고
    • Comparison of two continuous cardiac output pulmonary artery catheters
    • 19. Engoren M, Tennant RN: Comparison of two continuous cardiac output pulmonary artery catheters. Abstr. Anesth Analg 1996; 82:S102
    • (1996) Anesth Analg , vol.82
    • Engoren, M.1    Tennant, R.N.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.