메뉴 건너뛰기




Volumn 22, Issue 12, 1999, Pages 1829-1830

Intrapulmonary artery and intrabronchial migration and extraction of a fragment of J-shaped atrial pacing catheter

Author keywords

Atrial lead; Bronchial perforation; Lead fragment

Indexed keywords

ADULT; ARTICLE; BRONCHOSCOPY; CASE REPORT; CLINICAL FEATURE; DIAGNOSTIC IMAGING; HUMAN; PATHOLOGICAL ANATOMY; PROSTHESIS LOOSENING; PULMONARY ARTERY;

EID: 0033395619     PISSN: 01478389     EISSN: None     Source Type: Journal    
DOI: 10.1111/j.1540-8159.1999.tb00421.x     Document Type: Article
Times cited : (6)

References (7)
  • 2
    • 0028997067 scopus 로고
    • Atrial J pacing lead retention wire fracture: Radiographic assessment, incidence of fracture, and clinical management
    • 2. Lloyd MA, Hayes DL, Holmes DR. Atrial J pacing lead retention wire fracture: Radiographic assessment, incidence of fracture, and clinical management. PACE 1995; 18:958-964.
    • (1995) PACE , vol.18 , pp. 958-964
    • Lloyd, M.A.1    Hayes, D.L.2    Holmes, D.R.3
  • 3
    • 84981575468 scopus 로고
    • The retention wire fix
    • 3. Parsonnet V. The retention wire fix. PACE 1995; 18:955-957.
    • (1995) PACE , vol.18 , pp. 955-957
    • Parsonnet, V.1
  • 4
    • 0008923067 scopus 로고
    • Does the morbidity and mortality of extraction of the Teletronics Atrial Accufix lead outweigh that of its natural history?
    • 4. Reeves R, Brinker J, Kawanishi D, et al. Does the morbidity and mortality of extraction of the Teletronics Atrial Accufix lead outweigh that of its natural history? (abstract) Circulation 1995; 8:150.
    • (1995) Circulation , vol.8 , pp. 150
    • Reeves, R.1    Brinker, J.2    Kawanishi, D.3
  • 5
    • 0008930081 scopus 로고
    • Plus de 60 extractions de sondes Telectronics Accufix par un procédé sur, rapide et économique
    • 5. Laborde G. Plus de 60 extractions de sondes Telectronics Accufix par un procédé sur, rapide et économique. Stimucoeur 1995; 23:231-233.
    • (1995) Stimucoeur , vol.23 , pp. 231-233
    • Laborde, G.1
  • 6
    • 0008956520 scopus 로고
    • Experience with explanting Telectronics Accufix Atrial J leads
    • 6. Parsonnet V, Roelke M, Jacksic E, et al. Experience with explanting Telectronics Accufix Atrial J leads. (abstract) Circulation 1995; 8:150.
    • (1995) Circulation , vol.8 , pp. 150
    • Parsonnet, V.1    Roelke, M.2    Jacksic, E.3
  • 7
    • 0029123917 scopus 로고
    • Migration of a fractured retention wire in the pulmonary artery from an active fixation atrial lead
    • 7. Kao HL, Wang SS, Chen WJ, et al. Migration of a fractured retention wire in the pulmonary artery from an active fixation atrial lead. PACE 1995; 18:1966-1967.
    • (1995) PACE , vol.18 , pp. 1966-1967
    • Kao, H.L.1    Wang, S.S.2    Chen, W.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.