메뉴 건너뛰기




Volumn 15, Issue 6, 1999, Pages 347-356

Ergonomic automated anesthesia recordkeeper using a mobile touch screen with voice navigation

Author keywords

Anesthesia workstation; Anthropometric workspace design; Automated record keeping; Human ergonomics; Patient data management system; Voice response

Indexed keywords

ANESTHESIOLOGY; COMPUTER SOFTWARE; DATA ACQUISITION; ERGONOMICS; SPEECH RECOGNITION; USER INTERFACES;

EID: 0033385789     PISSN: 13871307     EISSN: None     Source Type: Journal    
DOI: 10.1023/A:1009972223750     Document Type: Article
Times cited : (6)

References (22)
  • 4
    • 0028965071 scopus 로고
    • Automated anesthesia record systems, observations on future trends of development
    • Heinrichs W. Automated anesthesia record systems, observations on future trends of development. Int J Clin Monit Comput 1995; 12: 17-20
    • (1995) Int J Clin Monit Comput , vol.12 , pp. 17-20
    • Heinrichs, W.1
  • 5
    • 0343831885 scopus 로고
    • The automated anesthesia record: Software design philosophy
    • Gravenstein J, Newbower R, Ream A et al, eds. Boston: Butterworth
    • Ream A. The automated anesthesia record: Software design philosophy. In: Gravenstein J, Newbower R, Ream A et al, eds. The automated anesthesia record and alarm systems. Boston: Butterworth, 1987: 17-32
    • (1987) The Automated Anesthesia Record and Alarm Systems , pp. 17-32
    • Ream, A.1
  • 6
    • 0342960814 scopus 로고    scopus 로고
    • Automated anesthesia record keeper can make the trustful database automatically (Abstract)
    • Sanjo Y, Ikeda K. Automated anesthesia record keeper can make the trustful database automatically (Abstract). Int J Clin Monit Comput 1996; 13: 198
    • (1996) Int J Clin Monit Comput , vol.13 , pp. 198
    • Sanjo, Y.1    Ikeda, K.2
  • 7
    • 0343396244 scopus 로고
    • Ergonomic design of VOCAAR (Voice Oriented Command Automated Anesthesia Recorder) and its first clinical installation (Abstract)
    • Sanjo Y, Ikeda K, Nakajima R. Ergonomic design of VOCAAR (Voice Oriented Command Automated Anesthesia Recorder) and its first clinical installation (Abstract). Int J Clin Monit Comput 1994; 11: 198
    • (1994) Int J Clin Monit Comput , vol.11 , pp. 198
    • Sanjo, Y.1    Ikeda, K.2    Nakajima, R.3
  • 8
    • 0343396245 scopus 로고    scopus 로고
    • Aspect of human ergonomics for anesthesia information systems: The VOCAARR project (Abstract)
    • Ikeda K, Doi M, Kazama T, eds. Dordrecht: Kluwer
    • Sanjo Y, Ikeda K. Aspect of human ergonomics for anesthesia information systems: The VOCAARR project (Abstract). In: Ikeda K, Doi M, Kazama T, eds. Proceedings of 18th International Symposium of Computing in Anesthesia. Dordrecht: Kluwer, 1998: 261-270
    • (1998) Proceedings of 18th International Symposium of Computing in Anesthesia , pp. 261-270
    • Sanjo, Y.1    Ikeda, K.2
  • 9
    • 0343396246 scopus 로고    scopus 로고
    • The anesthesia workstation
    • Lichter JL, Miller RD, eds. Philadelphia: Current Medicine
    • Sanjo Y, Ikeda K. The anesthesia workstation. In: Lichter JL, Miller RD, eds. Atlas of anesthesia 3. Philadelphia: Current Medicine, 1997: 1-1
    • (1997) Atlas of Anesthesia 3 , pp. 1-1
    • Sanjo, Y.1    Ikeda, K.2
  • 10
    • 0343831883 scopus 로고
    • Entry of drug administration data
    • Gravenstein J, Newbower R, Ream A et al, eds. Boston: Butterworth
    • Block FE. Entry of drug administration data. In: Gravenstein J, Newbower R, Ream A et al, eds. The automated anesthesia record and alarm systems. Boston: Butterworth, 1987: 93-98
    • (1987) The Automated Anesthesia Record and Alarm Systems , pp. 93-98
    • Block, F.E.1
  • 11
    • 0342526608 scopus 로고
    • Human factors in the man-machine interface
    • Gravenstein JS, Newbower R, Ream R et al, eds. Boston: Butterworth
    • Mitchell MM. Human factors in the man-machine interface. In: Gravenstein JS, Newbower R, Ream R et al, eds. The automated anesthesia record and alarm systems. Boston: Butterworth, 1987: 33-48
    • (1987) The Automated Anesthesia Record and Alarm Systems , pp. 33-48
    • Mitchell, M.M.1
  • 12
    • 0343831884 scopus 로고
    • Off-line human interface to describe the information on AAR with voice guidance and touch screen input
    • Mori H, Kazama T, Ikeda K, eds. Tokyo: Kokusedo
    • Sanjo Y et al. Off-line human interface to describe the information on AAR with voice guidance and touch screen input. In: Mori H, Kazama T, Ikeda K, eds. Proceedings of 1994 Japanese Society of Technology in Anesthesia and Intensive Care. Tokyo: Kokusedo, 1994: 58-64
    • (1994) Proceedings of 1994 Japanese Society of Technology in Anesthesia and Intensive Care , pp. 58-64
    • Sanjo, Y.1
  • 13
    • 0026026323 scopus 로고
    • Computerization of anesthesia information management
    • Eichhorn JH, Edsall DW. Computerization of anesthesia information management. J Clin Monit 1991; 7: 71-82
    • (1991) J Clin Monit , vol.7 , pp. 71-82
    • Eichhorn, J.H.1    Edsall, D.W.2
  • 14
    • 0029870461 scopus 로고    scopus 로고
    • Automated record keeping - A nine year Italian experience
    • Lanza V. Automated record keeping - a nine year Italian experience. Int J Clin Monit Comput 1996; 13: 35-43
    • (1996) Int J Clin Monit Comput , vol.13 , pp. 35-43
    • Lanza, V.1
  • 15
    • 7144259072 scopus 로고    scopus 로고
    • The Arkive "Organizer" patient information management system: Experience at a university hospital
    • Block FE, Reynolds KM, McDonalds JS. The Arkive "Organizer" patient information management system: Experience at a university hospital. J Clin Monit 1998; 14: 89-94
    • (1998) J Clin Monit , vol.14 , pp. 89-94
    • Block, F.E.1    Reynolds, K.M.2    McDonalds, J.S.3
  • 16
    • 0029022935 scopus 로고
    • An expert system to teach troubleshooting of common problems associated with the automated anesthesia recordkeeper
    • Block FE, Reynolds KM, McDonald JS. An expert system to teach troubleshooting of common problems associated with the automated anesthesia recordkeeper. J Clin Monit 1995; 11: 207-211
    • (1995) J Clin Monit , vol.11 , pp. 207-211
    • Block, F.E.1    Reynolds, K.M.2    McDonald, J.S.3
  • 17
    • 39749093168 scopus 로고
    • The magical number of seven, plus or minus two. some limits on our capacity for processing information
    • Miller GA. The magical number of seven, plus or minus two. some limits on our capacity for processing information. Psychol Rev 1956; 63: 81-97
    • (1956) Psychol Rev , vol.63 , pp. 81-97
    • Miller, G.A.1
  • 18
    • 0020211567 scopus 로고
    • Automated anesthesia data management and recordkeeping
    • Mitchell MM. Automated anesthesia data management and recordkeeping. Med Instrum 1982; 16: 279-282
    • (1982) Med Instrum , vol.16 , pp. 279-282
    • Mitchell, M.M.1
  • 19
    • 0342549272 scopus 로고
    • Speech recognition for the automated anesthesia record
    • Gravenstein J, Newbower R, Ream A et al, eds. Boston: Butterworth
    • Smith NT. Speech recognition for the automated anesthesia record. In: Gravenstein J, Newbower R, Ream A et al, eds. The automated anesthesia record and alarm systems. Boston: Butterworth, 1987: 115-134
    • (1987) The Automated Anesthesia Record and Alarm Systems , pp. 115-134
    • Smith, N.T.1
  • 20
    • 0025130515 scopus 로고
    • Recognition accuracy with a voice-recognition system designed for anesthesia record keeping
    • Smith NT, Brien RA, Pettus DC, Jones BR, Quinn ML, Sarnat A. Recognition accuracy with a voice-recognition system designed for anesthesia record keeping. J Clin Monit 1990; 6: 299-306
    • (1990) J Clin Monit , vol.6 , pp. 299-306
    • Smith, N.T.1    Brien, R.A.2    Pettus, D.C.3    Jones, B.R.4    Quinn, M.L.5    Sarnat, A.6
  • 21
    • 25544457913 scopus 로고
    • Human interface to automated anesthesia record using speech recognition technology: 2nd report (Abstract in Japanese)
    • Sanjo Y, Kazuyuki I, Satoshi I, Reiko N. Human interface to automated anesthesia record using speech recognition technology: 2nd report (Abstract in Japanese). Masui 1990; 40: s316
    • (1990) Masui , vol.40
    • Sanjo, Y.1    Kazuyuki, I.2    Satoshi, I.3    Reiko, N.4
  • 22
    • 0030881501 scopus 로고    scopus 로고
    • The effect of electronic record keeping and trasesopageal echocardiography on task distribution, workload, and vigilance during cardiac anesthesia
    • Winger M, Herdon O, Gaba D. The effect of electronic record keeping and trasesopageal echocardiography on task distribution, workload, and vigilance during cardiac anesthesia. Anesthesiology 1997; 87: 144-155
    • (1997) Anesthesiology , vol.87 , pp. 144-155
    • Winger, M.1    Herdon, O.2    Gaba, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.