-
1
-
-
0027957377
-
Vancomycin redistribution: Dosing recommendations following high-flux hemodialysis
-
Pollard TA, Lampasona V, Akkerman S, Tom K, Hooks MA, Mullins RE, et al. Vancomycin redistribution: dosing recommendations following high-flux hemodialysis. Kidney Int 1994;45:232-7.
-
(1994)
Kidney Int
, vol.45
, pp. 232-237
-
-
Pollard, T.A.1
Lampasona, V.2
Akkerman, S.3
Tom, K.4
Hooks, M.A.5
Mullins, R.E.6
-
2
-
-
0030039451
-
Falsely elevated serum vancomycin concentrations in hemodialysis patients
-
Follin SL, Mueller BA, Scott MS. Falsely elevated serum vancomycin concentrations in hemodialysis patients. Am J Kidney Dis 1996;1:67-74.
-
(1996)
Am J Kidney Dis
, vol.1
, pp. 67-74
-
-
Follin, S.L.1
Mueller, B.A.2
Scott, M.S.3
-
3
-
-
0023266377
-
Overestimation of vancomycin concentrations utilizing fluorescence polarization immunoassay in patients on peritoneal dialysis
-
Morse GD, Nairn DK, Bertino JS, Walshe JJ. Overestimation of vancomycin concentrations utilizing fluorescence polarization immunoassay in patients on peritoneal dialysis. Ther Drug Monit 1987;2:212-5.
-
(1987)
Ther Drug Monit
, vol.2
, pp. 212-215
-
-
Morse, G.D.1
Nairn, D.K.2
Bertino, J.S.3
Walshe, J.J.4
-
4
-
-
0028803526
-
Comparison of high-performance liquid chromatography with fluorescence polarization immunoassay for the analysis of vancomycin in patients with chronic renal failure
-
Najjar TA, al-Dhuwailie AA, Tekle A. Comparison of high-performance liquid chromatography with fluorescence polarization immunoassay for the analysis of vancomycin in patients with chronic renal failure. J Chromatogr B Biomed Appl 1995;672:295-9.
-
(1995)
J Chromatogr B Biomed Appl
, vol.672
, pp. 295-299
-
-
Najjar, T.A.1
Al-Dhuwailie, A.A.2
Tekle, A.3
-
5
-
-
0032927464
-
Clinical significance of falsely elevated vancomycin concentrations in end-stage renal disease
-
Kim JS, Perkins RJ, Briceland LL, Tobin EH. Clinical significance of falsely elevated vancomycin concentrations in end-stage renal disease (letter). Ann Pharmacother 1999;33:116-8.
-
(1999)
Ann Pharmacother
, vol.33
, pp. 116-118
-
-
Kim, J.S.1
Perkins, R.J.2
Briceland, L.L.3
Tobin, E.H.4
-
6
-
-
0002609435
-
Structure studies on vancomycin
-
Marshall FJ. Structure studies on vancomycin. J Med Chem 1965;8:18-22.
-
(1965)
J Med Chem
, vol.8
, pp. 18-22
-
-
Marshall, F.J.1
-
7
-
-
0020849252
-
Vancomycin: Structure and transformation to CDP-1
-
Harris CM, Kopecka H, Harris TM. Vancomycin: structure and transformation to CDP-1. J Am Chem Soc 1983;105:6915-22.
-
(1983)
J Am Chem Soc
, vol.105
, pp. 6915-6922
-
-
Harris, C.M.1
Kopecka, H.2
Harris, T.M.3
-
8
-
-
0024445877
-
Potential problem with fluorescence polarization immunoassay cross-reactivity to vancomycin degradation product CDP-1: Its detection in sera of renally impaired patients
-
Anne L, Hu M, Chan K, Colin L, Gottwald K. Potential problem with fluorescence polarization immunoassay cross-reactivity to vancomycin degradation product CDP-1: its detection in sera of renally impaired patients. Ther Drug Monit 1989;11:585-91.
-
(1989)
Ther Drug Monit
, vol.11
, pp. 585-591
-
-
Anne, L.1
Hu, M.2
Chan, K.3
Colin, L.4
Gottwald, K.5
-
9
-
-
0023798597
-
The in-vitro degradation at 37 °C of vancomycin in serum, CAPD fluid and phosphate-buffered saline
-
White LO, Edwards R, Holt HA, Lovering A, Finch RG, Reeves DS. The in-vitro degradation at 37 °C of vancomycin in serum, CAPD fluid and phosphate-buffered saline. J Antimicrob Chemother 1988;22:739-45.
-
(1988)
J Antimicrob Chemother
, vol.22
, pp. 739-745
-
-
White, L.O.1
Edwards, R.2
Holt, H.A.3
Lovering, A.4
Finch, R.G.5
Reeves, D.S.6
-
10
-
-
0343320358
-
Principles of immunochemical methods
-
Tietz NW, ed. Philadelphia: WB Saunders Co.
-
Buffone GJ. Principles of immunochemical methods. In: Tietz NW, ed. Fundamentals of clinical chemistry. 3rd ed. Philadelphia: WB Saunders Co., 1987:144-57.
-
(1987)
Fundamentals of Clinical Chemistry. 3rd Ed.
, pp. 144-157
-
-
Buffone, G.J.1
-
11
-
-
0024348370
-
Clinical performance of the EMIT vancomycin assay
-
Yeo KT, Traverse W, Horowitz GL. Clinical performance of the EMIT vancomycin assay. Clin Chem 1989;35:1504-7.
-
(1989)
Clin Chem
, vol.35
, pp. 1504-1507
-
-
Yeo, K.T.1
Traverse, W.2
Horowitz, G.L.3
-
12
-
-
0029021358
-
Assay of vancomycin by fluorescence polarisation immunoassay and EMIT in patients with renal failure
-
Saunders NJ, Want SV, Adams DJ. Assay of vancomycin by fluorescence polarisation immunoassay and EMIT in patients with renal failure. J Antimicrob Chemother 1995;36:2411-5.
-
(1995)
J Antimicrob Chemother
, vol.36
, pp. 2411-2415
-
-
Saunders, N.J.1
Want, S.V.2
Adams, D.J.3
-
13
-
-
0027272827
-
Accuracy of vancomycin serum concentrations in patients with renal failure
-
Perino LM, Mueller BA. Accuracy of vancomycin serum concentrations in patients with renal failure. Ann Pharmacother 1993;27:892-3.
-
(1993)
Ann Pharmacother
, vol.27
, pp. 892-893
-
-
Perino, L.M.1
Mueller, B.A.2
-
14
-
-
0030023189
-
Instability of standard calibrators may be involved in overestimating vancomycin concentrations determined by fluorescence polarization immunoassay
-
Morishige H, Shuto H, Ieiri I, Otsubo K, Oishi R. Instability of standard calibrators may be involved in overestimating vancomycin concentrations determined by fluorescence polarization immunoassay. Ther Drug Monit 1996;18:80-5.
-
(1996)
Ther Drug Monit
, vol.18
, pp. 80-85
-
-
Morishige, H.1
Shuto, H.2
Ieiri, I.3
Otsubo, K.4
Oishi, R.5
-
15
-
-
0019412879
-
Fluorescence polarization immunoassay III: An automated system for therapeutic drug determination
-
Jolley ME, Stroupe SD, Schwenzer KS. Fluorescence polarization immunoassay III: an automated system for therapeutic drug determination. Clin Chem 1981;27:1575-9.
-
(1981)
Clin Chem
, vol.27
, pp. 1575-1579
-
-
Jolley, M.E.1
Stroupe, S.D.2
Schwenzer, K.S.3
-
16
-
-
0242519886
-
Fluorometry, nephelometry, and turbidimetry
-
Tietz NW, ed. Philadelphia: WB Saunders Co.
-
Tiffany TO, Burtis CA. Fluorometry, nephelometry, and turbidimetry. In: Tietz NW, ed. Fundamentals of clinical chemistry. 3rd ed. Philadelphia: WB Saunders Co., 1987:66-73.
-
(1987)
Fundamentals of Clinical Chemistry. 3rd Ed.
, pp. 66-73
-
-
Tiffany, T.O.1
Burtis, C.A.2
-
17
-
-
0026325757
-
Cross-reactivity of a vancomycin degradation product in three immunoassays of vancomycin
-
Hortin GL, Landt M, Wilhite T, Smith CH. Cross-reactivity of a vancomycin degradation product in three immunoassays of vancomycin (letter). Clin Chem 1991;37:2009.
-
(1991)
Clin Chem
, vol.37
, pp. 2009
-
-
Hortin, G.L.1
Landt, M.2
Wilhite, T.3
Smith, C.H.4
-
18
-
-
0025633623
-
12 internal standard: Comparison of HPLC, EMIT, and FPIa methods
-
12 internal standard: comparison of HPLC, EMIT, and FPIA methods. Ther Drug Monit 1990;6:562-9.
-
(1990)
Ther Drug Monit
, vol.6
, pp. 562-569
-
-
Hu, M.W.1
Anne, L.2
Forni, T.3
Gottwald, K.4
-
19
-
-
0019472332
-
Vancomycin therapy in patients with impaired renal function: A nomogram for dosage
-
Moellering RO, Krogstad DJ, Greenblatt DJ. Vancomycin therapy in patients with impaired renal function: a nomogram for dosage. Ann Intern Med 1981;94:343-6.
-
(1981)
Ann Intern Med
, vol.94
, pp. 343-346
-
-
Moellering, R.O.1
Krogstad, D.J.2
Greenblatt, D.J.3
-
20
-
-
0029838032
-
Vancomycin serum concentrations in patients with renal dysfunction: A comparison of fluorescence polarization immunoassay and the enzyme-multiplied immunoassay technique
-
Peckman HJ, Dupuis RE, Sawyer WT, Brouwer KLR, Cross RE. Vancomycin serum concentrations in patients with renal dysfunction: a comparison of fluorescence polarization immunoassay and the enzyme-multiplied immunoassay technique. Ther Drug Monit 1996;18:647-53.
-
(1996)
Ther Drug Monit
, vol.18
, pp. 647-653
-
-
Peckman, H.J.1
Dupuis, R.E.2
Sawyer, W.T.3
Brouwer, K.L.R.4
Cross, R.E.5
-
21
-
-
0018877552
-
Clinical pharmacology and efficacy of vancomycin in pediatric patients
-
Schaad UB, McCracken GH, Nelson JD. Clinical pharmacology and efficacy of vancomycin in pediatric patients. J Pediatr 1980;96:119-26.
-
(1980)
J Pediatr
, vol.96
, pp. 119-126
-
-
Schaad, U.B.1
McCracken, G.H.2
Nelson, J.D.3
-
22
-
-
0028891567
-
Association of vancomycin serum concentrations with outcomes in patients with gram-positive bacteremia
-
Zimmerman Z, Katona BG, Plaisance KI. Association of vancomycin serum concentrations with outcomes in patients with gram-positive bacteremia. Pharmacotherapy 1995;1:85-91.
-
(1995)
Pharmacotherapy
, vol.1
, pp. 85-91
-
-
Zimmerman, Z.1
Katona, B.G.2
Plaisance, K.I.3
-
23
-
-
0031967090
-
Development of a quantitative vancomycin immunoassay for the Abbott AxSYM analyzer
-
Adamczyk M, Brate EM, Chiappetta EG, Ginsburg S, Hoffman E, Klein C, et al. Development of a quantitative vancomycin immunoassay for the Abbott AxSYM analyzer. Ther Drug Monit 1998;20:191-201.
-
(1998)
Ther Drug Monit
, vol.20
, pp. 191-201
-
-
Adamczyk, M.1
Brate, E.M.2
Chiappetta, E.G.3
Ginsburg, S.4
Hoffman, E.5
Klein, C.6
-
24
-
-
0345647092
-
Abbott AxSYM Vancomycin II assay: Multicenter evaluation and interference studies
-
Azzazy HM, Chou PP, Tsushima JH, Troxil S, Gordon M, Avers RJ, et al. Abbott AxSYM Vancomycin II assay: multicenter evaluation and interference studies. Ther Drug Monit 1998;20:202-8.
-
(1998)
Ther Drug Monit
, vol.20
, pp. 202-208
-
-
Azzazy, H.M.1
Chou, P.P.2
Tsushima, J.H.3
Troxil, S.4
Gordon, M.5
Avers, R.J.6
-
25
-
-
0031980142
-
New modified fluorescence polarization immunoassay does not falsely elevate vancomycin concentrations in patients with end-stage renal disease
-
Smith PF, Petros WP, Soucie MP, Copeland KR. New modified fluorescence polarization immunoassay does not falsely elevate vancomycin concentrations in patients with end-stage renal disease. Ther Drug Monit 1998;20:231-5.
-
(1998)
Ther Drug Monit
, vol.20
, pp. 231-235
-
-
Smith, P.F.1
Petros, W.P.2
Soucie, M.P.3
Copeland, K.R.4
-
26
-
-
0019492655
-
Metabolite interference in homogeneous enzyme immunoassay of phenytoin
-
Aldwin L, Kabakoff DS. Metabolite interference in homogeneous enzyme immunoassay of phenytoin (letter). Clin Chem 1981;27:770-1.
-
(1981)
Clin Chem
, vol.27
, pp. 770-771
-
-
Aldwin, L.1
Kabakoff, D.S.2
-
27
-
-
0019497186
-
Elevated serum phenytoin concentrations in a uremic patient when measured by enzyme-multiplied immunoassay
-
Matzke GR, Sawchuk RJ. Elevated serum phenytoin concentrations in a uremic patient when measured by enzyme-multiplied immunoassay. Drug Intell Clin Pharm 1981;15:386-8.
-
(1981)
Drug Intell Clin Pharm
, vol.15
, pp. 386-388
-
-
Matzke, G.R.1
Sawchuk, R.J.2
-
28
-
-
0021330867
-
Contribution of 5-(4-hydroxy-phenyl)-5-phenyl-hydantoin to the discrepancy between phenytoin analysis by EMIT and high-pressure liquid chromatography
-
Sawchuk RJ, Matzke GR. Contribution of 5-(4-hydroxy-phenyl)-5-phenyl-hydantoin to the discrepancy between phenytoin analysis by EMIT and high-pressure liquid chromatography. Ther Drug Monit 1984; 6:97-103.
-
(1984)
Ther Drug Monit
, vol.6
, pp. 97-103
-
-
Sawchuk, R.J.1
Matzke, G.R.2
-
29
-
-
0020823706
-
Increase in apparent theophylline concentration in the serum of two uremic patients as measured by some immunoassay methods (caused by 1,3-dimethyluric acid)
-
Opheim KE, Ainardi V. Increase in apparent theophylline concentration in the serum of two uremic patients as measured by some immunoassay methods (caused by 1,3-dimethyluric acid) (letter). Clin Chem 1983;29: 1698-9.
-
(1983)
Clin Chem
, vol.29
, pp. 1698-1699
-
-
Opheim, K.E.1
Ainardi, V.2
-
30
-
-
0021201141
-
Spurious phenobarbital levels by fluorescence polarization immunoassay using TDx analyzer in patients with renal disease
-
Bridges RR, Jennison TA. Spurious phenobarbital levels by fluorescence polarization immunoassay using TDx analyzer in patients with renal disease. Ther Drug Monit 1984;6:368-70.
-
(1984)
Ther Drug Monit
, vol.6
, pp. 368-370
-
-
Bridges, R.R.1
Jennison, T.A.2
-
31
-
-
0021869502
-
Morphine-6-glucuronide, an important factor in interpreting morphine radioimmunoassays
-
Aherne GW, Littleton P. Morphine-6-glucuronide, an important factor in interpreting morphine radioimmunoassays. Lancet 1985;2:210-1.
-
(1985)
Lancet
, vol.2
, pp. 210-211
-
-
Aherne, G.W.1
Littleton, P.2
-
32
-
-
0021828968
-
Influence of uremia on four assays for theophylline: Improved results with a monoclonal antibody in the TDx procedure
-
Compton R, Lichti D. Influence of uremia on four assays for theophylline: improved results with a monoclonal antibody in the TDx procedure. Clin Chem 1985;31:152-4.
-
(1985)
Clin Chem
, vol.31
, pp. 152-154
-
-
Compton, R.1
Lichti, D.2
-
33
-
-
0342885437
-
Determination of serum phenytoin in uremic and non-uremic patients using EMIT monoclonal assay
-
Raisys VA, Opheim KE, Thorson CS, Ainardi V. Determination of serum phenytoin in uremic and non-uremic patients using EMIT monoclonal assay (abstract). Clin Chem 1985;31:931.
-
(1985)
Clin Chem
, vol.31
, pp. 931
-
-
Raisys, V.A.1
Opheim, K.E.2
Thorson, C.S.3
Ainardi, V.4
-
36
-
-
0028568529
-
Vancomycin serum concentration monitoring: A continued debate
-
Pryka RD. Vancomycin serum concentration monitoring: a continued debate. Ann Pharmacother 1994;28:1397-9.
-
(1994)
Ann Pharmacother
, vol.28
, pp. 1397-1399
-
-
Pryka, R.D.1
|