메뉴 건너뛰기




Volumn 19, Issue 5, 1999, Pages 451-454

Surgical management of refractory exit-site/tunnel infection of Tenckhoff catheter: Technical innovations of partial replantation

Author keywords

Exit site tunnel infection; Partial replantation of Tenckhoff catheter

Indexed keywords

ANTIBIOTIC AGENT; CEFALEXIN;

EID: 0033376162     PISSN: 08968608     EISSN: None     Source Type: Journal    
DOI: 10.1177/089686089901900508     Document Type: Article
Times cited : (34)

References (8)
  • 1
    • 84979365574 scopus 로고
    • Peritoneal dialysis catheter exit site infections: Prevention, diagnosis, treatment and future directions
    • Twardowski ZJ. Peritoneal dialysis catheter exit site infections: prevention, diagnosis, treatment and future directions. Semin Dial 1992; 5:305-15.
    • (1992) Semin Dial , vol.5 , pp. 305-315
    • Twardowski, Z.J.1
  • 2
    • 0022909163 scopus 로고
    • The influence of peritoneal catheter exit-site infections on peritonitis, tunnel infections, and catheter loss in patients on continuous ambulatory peritoneal dialysis
    • Piraino B, Bernardini J, Sorkin M. The influence of peritoneal catheter exit-site infections on peritonitis, tunnel infections, and catheter loss in patients on continuous ambulatory peritoneal dialysis. Am J Kidney Dis 1986; 8:436-40.
    • (1986) Am J Kidney Dis , vol.8 , pp. 436-440
    • Piraino, B.1    Bernardini, J.2    Sorkin, M.3
  • 3
    • 0026356549 scopus 로고
    • Exit-site and tunnel infections in continuous ambulatory peritoneal dialysis patients
    • Scalamogna A, Castelnovo C, Vecchi AD, Ponticelli C. Exit-site and tunnel infections in continuous ambulatory peritoneal dialysis patients. Am J Kidney Dis 1991; 18:674-7.
    • (1991) Am J Kidney Dis , vol.18 , pp. 674-677
    • Scalamogna, A.1    Castelnovo, C.2    Vecchi, A.D.3    Ponticelli, C.4
  • 4
    • 0029830071 scopus 로고    scopus 로고
    • Peritonitis associated with exit site and tunnel infections
    • Gupta B, Bernardini B, Piraino B. Peritonitis associated with exit site and tunnel infections. Am J Kidney Dis 1996; 28:415-19.
    • (1996) Am J Kidney Dis , vol.28 , pp. 415-419
    • Gupta, B.1    Bernardini, B.2    Piraino, B.3
  • 5
    • 0030181003 scopus 로고    scopus 로고
    • Partial replantation of Tenckhoff catheters to treat intractable exit-site/tunnel infection
    • Chao SH, Tsai TJ. Partial replantation of Tenckhoff catheters to treat intractable exit-site/tunnel infection. J Am Soc Nephrol 1996; 7:1085-7.
    • (1996) J Am Soc Nephrol , vol.7 , pp. 1085-1087
    • Chao, S.H.1    Tsai, T.J.2
  • 6
    • 0024409479 scopus 로고
    • Catheter infections as a factor in the transfer of continuous ambulatory peritoneal dialysis patients to hemodialysis
    • Piraino B, Bernardini J, Sorkin M. Catheter infections as a factor in the transfer of continuous ambulatory peritoneal dialysis patients to hemodialysis. Am J Kidney Dis 1989; 13:365-9.
    • (1989) Am J Kidney Dis , vol.13 , pp. 365-369
    • Piraino, B.1    Bernardini, J.2    Sorkin, M.3
  • 7
    • 0024422908 scopus 로고
    • Ultrasound as a tool in the diagnosis and management of exit-site infections in patients undergoing continuous ambulatory peritoneal dialysis
    • Holley JL, Foulks CJ, Moss AH, Willard D. Ultrasound as a tool in the diagnosis and management of exit-site infections in patients undergoing continuous ambulatory peritoneal dialysis. Am J Kidney Dis 1989; 14:211-16.
    • (1989) Am J Kidney Dis , vol.14 , pp. 211-216
    • Holley, J.L.1    Foulks, C.J.2    Moss, A.H.3    Willard, D.4
  • 8
    • 0031888172 scopus 로고    scopus 로고
    • New criteria for management of catheter infections in peritoneal dialysis patients using ultrasonography
    • Vychytil A, Lorenz M, Schneider B, Horl WH, Haag-Weber M. New criteria for management of catheter infections in peritoneal dialysis patients using ultrasonography. J Am Soc Nephrol 1998; 9:290-6.
    • (1998) J Am Soc Nephrol , vol.9 , pp. 290-296
    • Vychytil, A.1    Lorenz, M.2    Schneider, B.3    Horl, W.H.4    Haag-Weber, M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.