메뉴 건너뛰기




Volumn 62, Issue 12, 1999, Pages 914-916

Pulse oximeter-associated toe injuries in a premature neonate: A case report

Author keywords

Burn injury; Oximetry probe; Premature infant; Pulse oximeter

Indexed keywords

ARTICLE; BURN; CASE REPORT; CRITICAL ILLNESS; EXPERIENCE; HEART OUTPUT; HUMAN; INFANT; INJURY; INTENSIVE CARE; MALE; PERIPHERAL CIRCULATION; PREMATURITY; PULSE OXIMETER; SKIN NECROSIS; TOE;

EID: 0033372370     PISSN: 05781337     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (8)
  • 1
    • 0024523226 scopus 로고
    • Principles of pulse oximetry: Theoretical and practical considerations
    • Alexander CM, Teller LE, Gross JB. Principles of pulse oximetry: theoretical and practical considerations. Anesth Analg 1989;68:368-76.
    • (1989) Anesth Analg , vol.68 , pp. 368-376
    • Alexander, C.M.1    Teller, L.E.2    Gross, J.B.3
  • 3
    • 0023514437 scopus 로고
    • Burn and "suntan" with the use of oximetry in infants
    • Miyasaka K, Ohata J. Burn and "suntan" with the use of oximetry in infants. Anesthesiology 1987;67:1008-9.
    • (1987) Anesthesiology , vol.67 , pp. 1008-1009
    • Miyasaka, K.1    Ohata, J.2
  • 4
    • 0023935878 scopus 로고
    • Finger injury by a pulse oximeter saturation monitor probe
    • Sloan TB. Finger injury by a pulse oximeter saturation monitor probe. Anesthesiology 1988;68:936-8.
    • (1988) Anesthesiology , vol.68 , pp. 936-938
    • Sloan, T.B.1
  • 5
    • 0026587313 scopus 로고
    • Bums due to pulse oximetry
    • Mills GH, Ralph SJ. Bums due to pulse oximetry. Anaesthesia 1992;47:276-7.
    • (1992) Anaesthesia , vol.47 , pp. 276-277
    • Mills, G.H.1    Ralph, S.J.2
  • 6
    • 0026502101 scopus 로고
    • Burning of a neonate due to a pulse oximeter: Arterial saturation monitoring
    • Deniel BS. Burning of a neonate due to a pulse oximeter: arterial saturation monitoring. Pediatrics 1992;89:154-5.
    • (1992) Pediatrics , vol.89 , pp. 154-155
    • Deniel, B.S.1
  • 7
    • 0026628253 scopus 로고
    • Skin injury in an infant with pulse oximetry
    • Pettersen B, Kongsgaard U, Aune H. Skin injury in an infant with pulse oximetry. Br J Anaesth 1992;69:204-5.
    • (1992) Br J Anaesth , vol.69 , pp. 204-205
    • Pettersen, B.1    Kongsgaard, U.2    Aune, H.3
  • 8
    • 85088327768 scopus 로고
    • Digital sensory loss without pulse oximeter malfunction
    • Patrick JD. Digital sensory loss without pulse oximeter malfunction. Anesth Analg 1995;81:1312.
    • (1995) Anesth Analg , vol.81 , pp. 1312
    • Patrick, J.D.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.