A laminar flow test object based on the draft IEC 61685 standard for quality assurance of ultrasound doppler equipment;Ein testobjekt fur die apparative qualitatssicherung bei ultraschalldoppler(duplex)-geraten, ausgehend vom normenentwurf IEC 61685

Author keywords

Flow test object; Performance parameter; Quality assurance; Standardisation; Ultrasound Doppler

Indexed keywords

ARTICLE; DOPPLER ECHOGRAPHY; MEDICAL TECHNOLOGY; QUALITY CONTROL; STANDARDIZATION; BLOOD; COMPUTER SIMULATION; EUROPE; EUROPEAN UNION; HEALTH CARE QUALITY; HUMAN; IMAGE PROCESSING; IMAGE QUALITY; INSTRUMENTATION; INTERNATIONAL COOPERATION; STANDARD;

EID: 0033370750     PISSN: 01724614     EISSN: None     Source Type: Journal    
DOI: 10.1055/s-1999-8918     Document Type: Article
Times cited : (9)

References (18)
  • 2
    • 0342286118 scopus 로고
    • Bonn BCBI. I 1963
    • Bundesministerium für Gesundheit. Medizinproduktegesetz, Bonn BCBI. 1994 I 1963
    • (1994) Medizinproduktegesetz
  • 5
    • 0031025901 scopus 로고    scopus 로고
    • Accuracy of Doppler catheter measurements: Effect of inhomogeneous beam power distribution on mean and peak velocity
    • Denardo SJ, Talbot L, Hargrave VK, Selfridge AR, Ports TA, Yock PG. Accuracy of Doppler catheter measurements: effect of inhomogeneous beam power distribution on mean and peak velocity. J Aml Coll Cardiol 1997; 29/2: 283-292
    • (1997) J Aml Coll Cardiol , vol.29 , Issue.2 , pp. 283-292
    • Denardo, S.J.1    Talbot, L.2    Hargrave, V.K.3    Selfridge, A.R.4    Ports, T.A.5    Yock, P.G.6
  • 6
    • 0343131443 scopus 로고
    • 93/42/EEC Brussels
    • European Community. Medical Device Directive, 93/42/EEC Brussels: 1993
    • (1993) Medical Device Directive
  • 7
    • 0038720995 scopus 로고    scopus 로고
    • Draft IEC 1685 Standard, Technical Committee 87: Ultrasonics, Working Group document IEC 87/85/CD Geneva
    • International Electrotechnical Commission (IEC). Ultrasonics -Flow measurement systems - Flow test object. Draft IEC 1685 Standard, Technical Committee 87: Ultrasonics, Working Group document IEC 87/85/CD Geneva: 1995
    • (1995) Ultrasonics -Flow Measurement Systems - Flow Test Object
  • 8
    • 0038720995 scopus 로고    scopus 로고
    • Draft IEC 1685 Standard, IEC 87/121/CD, Date of circulation 02-13
    • International Electrotechnical Commission (IEC). Ultrasonics -Flow measurement systems - Flow test object. Draft IEC 1685 Standard, IEC 87/121/CD, Date of circulation 1998-02-13
    • (1998) Ultrasonics -Flow Measurement Systems - Flow Test Object
  • 10
    • 0343131442 scopus 로고
    • Kontrolle der bildqualität klinischer B-mode-ultraschallgeräte-kenngrößen und bewertungskriterien
    • Kollmann Ch, Bergmann H. Kontrolle der Bildqualität klinischer B-Mode-Ultraschallgeräte-Kenngrößen und Bewertungskriterien. Z Med Physik 1995; 5: 74-80
    • (1995) Z Med Physik , vol.5 , pp. 74-80
    • Kollmann, Ch.1    Bergmann, H.2
  • 11
    • 0032033499 scopus 로고    scopus 로고
    • Validation of a new blood-mimicking fluid for use in Doppler flow test objects
    • Ramnarine KV, Nassiri DK, Hoskins PR, Lubbers J. Validation of a new blood-mimicking fluid for use in Doppler flow test objects. Ultrasound Med Biol 1998; 24/3: 451-459
    • (1998) Ultrasound Med Biol , vol.24 , Issue.3 , pp. 451-459
    • Ramnarine, K.V.1    Nassiri, D.K.2    Hoskins, P.R.3    Lubbers, J.4
  • 12
    • 0032924378 scopus 로고    scopus 로고
    • Doppler backscatter properties of a blood-mimicking fluid for Doppler performance assessment
    • Ramnarine KV, Hoskins PR, Routh HF, Davidson F. Doppler backscatter properties of a blood-mimicking fluid for Doppler performance assessment. Ultrasound Med Biol 1999; 25/1: 105-110
    • (1999) Ultrasound Med Biol , vol.25 , Issue.1 , pp. 105-110
    • Ramnarine, K.V.1    Hoskins, P.R.2    Routh, H.F.3    Davidson, F.4
  • 13
    • 0025875681 scopus 로고
    • Estimation of ultrasound beam width in the elevation (section thickness) plane
    • Skolnick ML. Estimation of ultrasound beam width in the elevation (section thickness) plane. Radiology 1991; 180: 286-288
    • (1991) Radiology , vol.180 , pp. 286-288
    • Skolnick, M.L.1
  • 16
    • 0025986421 scopus 로고
    • Limitations of flow detection by color Doppler: In vitro comparison to conventional Doppler
    • Von Bibra H, Stempfle HU, Poll A, Scherer M, Bluml C, Blomer H. Limitations of flow detection by color Doppler: In vitro comparison to conventional Doppler. Echocardiography 1991; 8/6: 633-642
    • (1991) Echocardiography , vol.8 , Issue.6 , pp. 633-642
    • Von Bibra, H.1    Stempfle, H.U.2    Poll, A.3    Scherer, M.4    Bluml, C.5    Blomer, H.6
  • 17
    • 0030938068 scopus 로고    scopus 로고
    • Effects of velocity distribution, diameter measurement and velocity tracing on the accuracy of cardiac output measurement by pulsed Doppler echocardiography in the aortic annulus of pigs
    • Zhou YQ, Faerestrand S, Birkeland S, Matre K, Husby P, Koller ME. Effects of velocity distribution, diameter measurement and velocity tracing on the accuracy of cardiac output measurement by pulsed Doppler echocardiography in the aortic annulus of pigs. Ultrasound Med Biol 1997; 23/2: 177-185
    • (1997) Ultrasound Med Biol , vol.23 , Issue.2 , pp. 177-185
    • Zhou, Y.Q.1    Faerestrand, S.2    Birkeland, S.3    Matre, K.4    Husby, P.5    Koller, M.E.6
  • 18
    • 0032832938 scopus 로고    scopus 로고
    • Application of a new blood-mimicking fluid in a flow Doppler test object
    • Lubbers J. Application of a new blood-mimicking fluid in a flow Doppler test object. Radiology 1999; 9: 267-276
    • (1999) Radiology , vol.9 , pp. 267-276
    • Lubbers, J.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.