메뉴 건너뛰기




Volumn 15, Issue 6, 1999, Pages 29-37

Technical advances in the underground medium-voltage cable specification of the largest investor-owned utilities in the U.S.

Author keywords

[No Author keywords available]

Indexed keywords

ELECTRIC INSULATING MATERIALS; ELECTRIC UTILITIES; POLYETHYLENES; POLYPROPYLENES; SPECIFICATIONS; UNDERGROUND CABLES;

EID: 0033364841     PISSN: 08837554     EISSN: None     Source Type: Journal    
DOI: 10.1109/57.806377     Document Type: Article
Times cited : (5)

References (12)
  • 1
    • 0342670545 scopus 로고    scopus 로고
    • Edison Electric Institute, 701 Pennsylvania Ave., N.W., Washington, D.C. 20004
    • Catalog of Investor-Owned Utilities, 38th edition, Edison Electric Institute, 701 Pennsylvania Ave., N.W., Washington, D.C. 20004, 1998.
    • (1998) Catalog of Investor-Owned Utilities, 38th Edition
  • 2
    • 0028392145 scopus 로고
    • Technical trends in medium voltage urd cable specifications
    • March/April
    • J. H. Dudas, "Technical Trends in Medium Voltage URD Cable Specifications," IEEE Electrical Insulation Magazine, Vol. 10, No. 2, March/April 1994.
    • (1994) IEEE Electrical Insulation Magazine , vol.10 , Issue.2
    • Dudas, J.H.1
  • 3
    • 0343976654 scopus 로고    scopus 로고
    • AEIC CS5-94, Specifications for Crosslinked Polyethylene-Insulated Shielded Power Cables Rated 5 Through 69kV, and AEIC CS6-96, Specifications for Ethylene Propylene Rubber- Insulated Shielded Power Cables Rated 5 Through 69kV
    • AEIC CS5-94, Specifications for Crosslinked Polyethylene-Insulated Shielded Power Cables Rated 5 Through 69kV, and AEIC CS6-96, Specifications for Ethylene Propylene Rubber- Insulated Shielded Power Cables Rated 5 Through 69kV.
  • 4
    • 0343104920 scopus 로고
    • Comparative life tests of 20 kV cables with different compounds
    • March
    • R. M. Eichhorn, H. Schadlich, and W. Boone, "Comparative Life Tests of 20 kV Cables with Different Compounds," Jicable 91, March 1991.
    • (1991) Jicable , vol.91
    • Eichhorn, R.M.1    Schadlich, H.2    Boone, W.3
  • 5
    • 0024068849 scopus 로고
    • EPR-based URD insulation: A question of confidence
    • September/October
    • M. Brown, "EPR-Based URD Insulation: a Question of Confidence," IEEE Electrical Insulation Magazine, Vol. 4, No. 5, September/October 1988.
    • (1988) IEEE Electrical Insulation Magazine , vol.4 , Issue.5
    • Brown, M.1
  • 6
    • 0025694420 scopus 로고
    • A survey of URD cable installed in rural electric systems and failures of that cable
    • J. C. Dedman and H. L. Bowles, "A Survey of URD Cable Installed in Rural Electric Systems and Failures of That Cable," IEEE Rural Electric Power Conference, 1990.
    • (1990) IEEE Rural Electric Power Conference
    • Dedman, J.C.1    Bowles, H.L.2
  • 7
    • 0343104921 scopus 로고
    • HFDA 4202 NT EC eleven years of performance
    • December
    • S. Szaniszlo, "HFDA 4202 NT EC Eleven Years of Performance," Kabelitems Wire and Cable, No. 164, December 1994.
    • (1994) Kabelitems Wire and Cable , Issue.164
    • Szaniszlo, S.1
  • 8
    • 0025682647 scopus 로고
    • Performance of supersmooth extra clean semiconductive shields in XLPE-insulated power cables
    • June
    • N. M. Burns, Jr., "Performance of Supersmooth Extra Clean Semiconductive Shields in XLPE-Insulated Power Cables," IEE International Symposium on Electrical Insulation, June 1990.
    • (1990) IEE International Symposium on Electrical Insulation
    • Burns N.M., Jr.1
  • 9
    • 0343976650 scopus 로고
    • Supersmooth extra-clean semiconductives, an update
    • Appendix V-G-1, April
    • N. M. Burns, Jr., "Supersmooth Extra-clean Semiconductives, an Update," ICC-IEEE Minutes, Appendix V-G-1, April 1991.
    • (1991) ICC-IEEE Minutes
    • Burns N.M., Jr.1
  • 10
    • 0016942650 scopus 로고
    • Moisture absorption of crosslinked polyethylene-insulated cables in gas or steam
    • K. Soma, Y. Sekii, T. Endo and C. Ikeda, "Moisture Absorption of Crosslinked Polyethylene-Insulated Cables in Gas or Steam," Hitachi Review, Vol. 25, No. 4, 1976.
    • (1976) Hitachi Review , vol.25 , Issue.4
    • Soma, K.1    Sekii, Y.2    Endo, T.3    Ikeda, C.4
  • 11
    • 0342670540 scopus 로고
    • The 1990 AEIC cable engineering section cable operations report
    • November
    • A. Kong, "The 1990 AEIC Cable Engineering Section Cable Operations Report," ICC-IEEE Minutes, November 1991.
    • (1991) ICC-IEEE Minutes
    • Kong, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.