메뉴 건너뛰기




Volumn 20, Issue 4, 1999, Pages 541-545

Radiologic and histopathologic evaluation of canine artery occlusion after collagen-coated platinum microcoil delivery

Author keywords

[No Author keywords available]

Indexed keywords

COLLAGEN; PLATINUM;

EID: 0033361088     PISSN: 01956108     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (24)

References (29)
  • 1
    • 0026808426 scopus 로고
    • Endovascular treatment of posterior circulation aneurysms by electrothrombosis using electrically detachable coils
    • Guglielmi G, Viñuela F, Duckwiler G, et al. Endovascular treatment of posterior circulation aneurysms by electrothrombosis using electrically detachable coils. J Neurosurg 1992;77:515-525
    • (1992) J Neurosurg , vol.77 , pp. 515-525
    • Guglielmi, G.1    Viñuela, F.2    Duckwiler, G.3
  • 3
    • 0026355516 scopus 로고
    • Electrothrombosis of saccular aneurysms via endovascular approach. Part 2: Preliminary clinical experience
    • Guglielmi G, Viñuela F, Dion J, Duckwiler G. Electrothrombosis of saccular aneurysms via endovascular approach. Part 2: preliminary clinical experience. J Neurosurg 1991;75:8-14
    • (1991) J Neurosurg , vol.75 , pp. 8-14
    • Guglielmi, G.1    Viñuela, F.2    Dion, J.3    Duckwiler, G.4
  • 4
    • 0028889343 scopus 로고
    • Neurosurgical management of cerebral aneurysms following unsuccessful or incomplete endovascular embolization
    • Gurian JH, Martin NA, King WA, Duckwiler GR, Guglielmi G, Viñuela F. Neurosurgical management of cerebral aneurysms following unsuccessful or incomplete endovascular embolization. J Neurosurg 1995;83:843-853
    • (1995) J Neurosurg , vol.83 , pp. 843-853
    • Gurian, J.H.1    Martin, N.A.2    King, W.A.3    Duckwiler, G.R.4    Guglielmi, G.5    Viñuela, F.6
  • 5
    • 0002962386 scopus 로고
    • Early clinical outcome of patients with ruptured cerebral aneurysms treated by endovascular (GDC) or microsurgical techniques
    • Richling B, Bavinzski G, Gross C, Gruber A, Killer M. Early clinical outcome of patients with ruptured cerebral aneurysms treated by endovascular (GDC) or microsurgical techniques. Intervent Neuroradiol 1995;1:19-27
    • (1995) Intervent Neuroradiol , vol.1 , pp. 19-27
    • Richling, B.1    Bavinzski, G.2    Gross, C.3    Gruber, A.4    Killer, M.5
  • 6
    • 0028937660 scopus 로고
    • Thrombosis in giant basilar tip aneurysms during coil embolization
    • Ronowden SA, Molyneux AJ. Thrombosis in giant basilar tip aneurysms during coil embolization. AJNR Am J Neuroradiol 1995;16:866-871
    • (1995) AJNR Am J Neuroradiol , vol.16 , pp. 866-871
    • Ronowden, S.A.1    Molyneux, A.J.2
  • 7
    • 0029822280 scopus 로고    scopus 로고
    • Microsurgically produced bifurcation aneurysms in a rabbit model for endovascular coil embolization
    • Spetzger U, Reul J, Weis J, Bertalanffy H, Thron A, Gilsbach JM. Microsurgically produced bifurcation aneurysms in a rabbit model for endovascular coil embolization. J Neurosurg 1996; 85:488-495
    • (1996) J Neurosurg , vol.85 , pp. 488-495
    • Spetzger, U.1    Reul, J.2    Weis, J.3    Bertalanffy, H.4    Thron, A.5    Gilsbach, J.M.6
  • 8
    • 0027300998 scopus 로고
    • Selective endovascular treatment of 71 intracranial aneurysms with platinum coils
    • Casasco AE, Aymard A, Gobin YP, et al. Selective endovascular treatment of 71 intracranial aneurysms with platinum coils. J Neurosurgery 1993;79:3-10
    • (1993) J Neurosurgery , vol.79 , pp. 3-10
    • Casasco, A.E.1    Aymard, A.2    Gobin, Y.P.3
  • 9
    • 0028895392 scopus 로고
    • Long-term histopathological changes in canine aneurysm embolized with Guglielmi detachable coil
    • Mawad ME, Mawad JK, Cartwright J Jr, Gokaslan Z. Long-term histopathological changes in canine aneurysm embolized with Guglielmi detachable coil. AJNR Am J Neuroradiol 1995;16:7-13
    • (1995) AJNR Am J Neuroradiol , vol.16 , pp. 7-13
    • Mawad, M.E.1    Mawad, J.K.2    Cartwright J., Jr.3    Gokaslan, Z.4
  • 10
    • 0027232687 scopus 로고
    • Endovascular packing of carotid bifurcation aneurysm with polyester fiber-coated platinum coils in a rabbit model
    • Kwan ES, Heilman CB, Roth PA. Endovascular packing of carotid bifurcation aneurysm with polyester fiber-coated platinum coils in a rabbit model. AJNR Am J Neuroradiol 1993;14: 323-333
    • (1993) AJNR Am J Neuroradiol , vol.14 , pp. 323-333
    • Kwan, E.S.1    Heilman, C.B.2    Roth, P.A.3
  • 11
    • 0031014385 scopus 로고    scopus 로고
    • Histological interaction of cultured endothelial cells and endovascular embolic materials coated with extracellular matrix
    • Tamatani S, Ozawa T, Minakawa T, Takeuchi S, Koike T, Tanaka R. Histological interaction of cultured endothelial cells and endovascular embolic materials coated with extracellular matrix. J Neurosurg 1997;86:109-112
    • (1997) J Neurosurg , vol.86 , pp. 109-112
    • Tamatani, S.1    Ozawa, T.2    Minakawa, T.3    Takeuchi, S.4    Koike, T.5    Tanaka, R.6
  • 12
    • 0342575203 scopus 로고    scopus 로고
    • Ion implantation and protein coating of detachable coils for endovascular treatment of cerebral aneurysms: Concepts and preliminary results in swine models
    • Murayama Y, Viñuela F, Suzuki Y, et al. Ion implantation and protein coating of detachable coils for endovascular treatment of cerebral aneurysms: concepts and preliminary results in swine models. Neurosurgery 1997;86:109-112.
    • (1997) Neurosurgery , vol.86 , pp. 109-112
    • Murayama, Y.1    Viñuela, F.2    Suzuki, Y.3
  • 15
    • 0026331291 scopus 로고
    • Electrothrombosis of saccular aneurysms via endovascular approach. Part 1: Electrochemical basis, technical and experimental results
    • Guglielmi G, Viñuela F, Sepetka I, Macellari V. Electrothrombosis of saccular aneurysms via endovascular approach. Part 1: electrochemical basis, technical and experimental results. J Neurosurgery 1991;75:1-7
    • (1991) J Neurosurgery , vol.75 , pp. 1-7
    • Guglielmi, G.1    Viñuela, F.2    Sepetka, I.3    Macellari, V.4
  • 16
    • 0028849307 scopus 로고
    • Effect of Guglielmi detachable coils on experimental carotid artery aneurysms in primates
    • Tenjin H, Fushiki S, Nakahara Y, et al. Effect of Guglielmi detachable coils on experimental carotid artery aneurysms in primates. Stroke 1995;26:2075-2080
    • (1995) Stroke , vol.26 , pp. 2075-2080
    • Tenjin, H.1    Fushiki, S.2    Nakahara, Y.3
  • 17
    • 0029069722 scopus 로고
    • Histopathological findings in giant aneurysms treated with Guglielmi detachable coils
    • Molyneux AJ, Ellison DW, Morris J, Byrne JV. Histopathological findings in giant aneurysms treated with Guglielmi detachable coils. J Neurosurg 1995;83:129-132
    • (1995) J Neurosurg , vol.83 , pp. 129-132
    • Molyneux, A.J.1    Ellison, D.W.2    Morris, J.3    Byrne, J.V.4
  • 18
    • 0032231472 scopus 로고    scopus 로고
    • Scanning electron microscopic study of the migrated platinum coil after endovascular embolization of a giant cerebral aneurysm
    • Ozawa T, Koike T, Takeuchi S, Tanaka R. Scanning electron microscopic study of the migrated platinum coil after endovascular embolization of a giant cerebral aneurysm (letter). AJNR Am J Neuroradiol 1998;19:594-595
    • (1998) AJNR Am J Neuroradiol , vol.19 , pp. 594-595
    • Ozawa, T.1    Koike, T.2    Takeuchi, S.3    Tanaka, R.4
  • 19
    • 0022643864 scopus 로고
    • A comparative study of the biological and immunological response to medical devices derived from dermal collagen
    • DeLustro F, Condell RA, Nguyem MA, McPherson JM. A comparative study of the biological and immunological response to medical devices derived from dermal collagen. J Biomed Mater Res 1986;20:93-107
    • (1986) J Biomed Mater Res , vol.20 , pp. 93-107
    • Delustro, F.1    Condell, R.A.2    Nguyem, M.A.3    McPherson, J.M.4
  • 20
    • 0000498227 scopus 로고
    • The classical collagens type I, II, and III
    • Kuhn K. Mayne R, and Burgeson RE, eds. London, England: Academic Press Inc
    • Kuhn K. The classical collagens type I, II, and III. In: Kuhn K. Structure and Function of Collagen Types. Mayne R, and Burgeson RE, eds. London, England: Academic Press Inc;1987;1-42
    • (1987) Structure and Function of Collagen Types , pp. 1-42
    • Kuhn, K.1
  • 22
    • 0014252860 scopus 로고
    • The fibroblast and wound repair
    • Ross R. The fibroblast and wound repair. Biol Rev 1968:43:51-96
    • (1968) Biol Rev , vol.43 , pp. 51-96
    • Ross, R.1
  • 23
    • 0014527756 scopus 로고
    • Wound healing
    • Ross R. Wound healing. Sci Am 1969;220:40-50
    • (1969) Sci Am , vol.220 , pp. 40-50
    • Ross, R.1
  • 24
    • 0343880959 scopus 로고
    • Fibroblast behavior on gels on type I, III, and IV human placental collagens
    • Tiollier J, Dumas H, Tardy M, Tayot JL. Fibroblast behavior on gels on type I, III, and IV human placental collagens. Exp Cell Res 1991;193:310-319
    • (1991) Exp Cell Res , vol.193 , pp. 310-319
    • Tiollier, J.1    Dumas, H.2    Tardy, M.3    Tayot, J.L.4
  • 25
    • 0029935353 scopus 로고    scopus 로고
    • Histologic effect of collagen-filled interlocking detachable coils in the ablation of experimental aneurysms in swine
    • Dowson RC, Shemgelania GG, Krisht AF, Bonner GD. Histologic effect of collagen-filled interlocking detachable coils in the ablation of experimental aneurysms in swine. AJNR Am J Neuroradiol 1996;17:853-858
    • (1996) AJNR Am J Neuroradiol , vol.17 , pp. 853-858
    • Dowson, R.C.1    Shemgelania, G.G.2    Krisht, A.F.3    Bonner, G.D.4
  • 26
    • 0016673374 scopus 로고
    • Coagulation and fibrinolysis in the dog
    • Cade JF, Robinson TF. Coagulation and fibrinolysis in the dog. Can J Comp Med 1975;39:296-298
    • (1975) Can J Comp Med , vol.39 , pp. 296-298
    • Cade, J.F.1    Robinson, T.F.2
  • 27
    • 0342575201 scopus 로고
    • Collagen microbeads: Experimental evaluation of an embolic agents in the rete mirabile of the swine
    • Turjman F, Massoud TF, Vinters HV, et al. Collagen microbeads: Experimental evaluation of an embolic agents in the rete mirabile of the swine. AJNR Am J Neuroradiol 1975;39:296-298
    • (1975) AJNR Am J Neuroradiol , vol.39 , pp. 296-298
    • Turjman, F.1    Massoud, T.F.2    Vinters, H.V.3
  • 28
    • 0025066426 scopus 로고
    • Immune responses to allogenic and xenogenic implants of collagen and collagen derivatives
    • De Lustro F, Dasch J, Keefe J, Ellingsworth L. Immune responses to allogenic and xenogenic implants of collagen and collagen derivatives. Clin Orthop 1990;260:263-279
    • (1990) Clin Orthop , vol.260 , pp. 263-279
    • De Lustro, F.1    Dasch, J.2    Keefe, J.3    Ellingsworth, L.4
  • 29
    • 0024433477 scopus 로고
    • Biocompatibility of human collagen type IV in intracorneal implant
    • Dupont D, Gravagna P, Albinet P, et al. Biocompatibility of human collagen type IV in intracorneal implant. Cornea 1989;8: 251-258
    • (1989) Cornea , vol.8 , pp. 251-258
    • Dupont, D.1    Gravagna, P.2    Albinet, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.