메뉴 건너뛰기




Volumn 36, Issue 5, 1999, Pages 397-402

Bayesian approach to the consumer's and producer's risks in measurement

Author keywords

[No Author keywords available]

Indexed keywords

BAYESIAN PROBABILITY; MEASURING INSTRUMENTS;

EID: 0033356284     PISSN: 00261394     EISSN: None     Source Type: Journal    
DOI: 10.1088/0026-1394/36/5/1     Document Type: Article
Times cited : (24)

References (18)
  • 4
    • 0027242748 scopus 로고
    • A Bayesian theory of measurement uncertainty
    • Weise K., Wöger W., A Bayesian theory of measurement uncertainty. Meas. Science Tech., 1993, 4, 1-11.
    • (1993) Meas. Science Tech. , vol.4 , pp. 1-11
    • Weise, K.1    Wöger, W.2
  • 5
    • 0033330885 scopus 로고    scopus 로고
    • Bayesian inference from measurement information
    • Lira I., Kyriazis G., Bayesian inference from measurement information, Metrologia, 1999, 36, 163-169.
    • (1999) Metrologia , vol.36 , pp. 163-169
    • Lira, I.1    Kyriazis, G.2
  • 8
    • 0022732808 scopus 로고
    • Probability assignment to systematic deviations by the principle of maximum entropy
    • Wöger W., Probability assignment to systematic deviations by the Principle of Maximum Entropy, IEEE Trans. Instrum. Meas., 1987, 36, 655-658.
    • (1987) IEEE Trans. Instrum. Meas. , vol.36 , pp. 655-658
    • Wöger, W.1
  • 9
    • 0343125160 scopus 로고    scopus 로고
    • Guardbanding and the world of ISO guide 25, is there only one way?
    • Boulder, Colo., National Conference of Standards Laboratories
    • Deaver D., Guardbanding and the world of ISO Guide 25, Is there only one way?, Proc. NCSL Workshop and Symposium, Boulder, Colo., National Conference of Standards Laboratories, 1998, 319-331.
    • (1998) Proc. NCSL Workshop and Symposium , pp. 319-331
    • Deaver, D.1
  • 11
    • 0031117268 scopus 로고    scopus 로고
    • A note on the evaluation of standard uncertainty in the presence of limited resolution of indicating devices
    • Lira I., Wöger W., A note on the evaluation of standard uncertainty in the presence of limited resolution of indicating devices, Meas. Science Tech., 1997, 8, 441-443.
    • (1997) Meas. Science Tech. , vol.8 , pp. 441-443
    • Lira, I.1    Wöger, W.2
  • 12
    • 0032140809 scopus 로고    scopus 로고
    • The evaluation of the uncertainty in knowing a directly measured quantity
    • Lira I., Wöger W., The evaluation of the uncertainty in knowing a directly measured quantity, Meas. Science Tech., 1998, 9, 1167-1173.
    • (1998) Meas. Science Tech. , vol.9 , pp. 1167-1173
    • Lira, I.1    Wöger, W.2
  • 15
    • 0343561093 scopus 로고    scopus 로고
    • The guidelines for expressing measurement uncertainties and the 4:1 test uncertainty ratio (TUR)
    • Boulder, Colo., National Conference of Standards Laboratories
    • Song J., The guidelines for expressing measurement uncertainties and the 4:1 test uncertainty ratio (TUR), Proc. NCSL Workshop and Symposium, Boulder, Colo., National Conference of Standards Laboratories, 1997, 5-12.
    • (1997) Proc. NCSL Workshop and Symposium , pp. 5-12
    • Song, J.1
  • 17
    • 0142039381 scopus 로고
    • A method for handling errors in testing and measuring
    • 10 March
    • Eagle A., A method for handling errors in testing and measuring, Industrial Quality Control, 1954, 10 March, 10-15.
    • (1954) Industrial Quality Control , pp. 10-15
    • Eagle, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.