1
-
-
0009246038
-
Failure mechanisms in total hip and knee arthroplasty
-
(Essen, Germany), 8-9 Oct
-
B. Barden, Failure Mechanisms in Total Hip and Knee Arthroplasty, Proc. Biomaterials: Fundamentals and Clinical Appl. (Essen, Germany), 8-9 Oct 1998, p 44
-
(1998)
Proc. Biomaterials: Fundamentals and Clinical Appl.
, pp. 44
-
-
Barden, B.1
-
2
-
-
0001166249
-
Survival rate and reliability of ceramic femoral heads for total hip arthroplasty
-
in German
-
G. Willmann, Survival Rate and Reliability of Ceramic Femoral Heads for Total Hip Arthroplasty, Mater.wiss. Werkst.tech., Vol 29, 1998, p 595-604 (in German)
-
(1998)
Mater.Wiss. Werkst.Tech.
, vol.29
, pp. 595-604
-
-
Willmann, G.1
-
3
-
-
0026521288
-
Hydroxyapatite coating modifies implant membrane formation. Controlled micromotion studies in dogs
-
K. Soballe, H.B. Rasmussen, E.S. Hansen, and C. Buenger, Hydroxyapatite Coating Modifies Implant Membrane Formation. Controlled Micromotion Studies in Dogs, Acta Orthop. Scand., Vol 63 (No. 2), 1992, p 128-140
-
(1992)
Acta Orthop. Scand.
, vol.63
, Issue.2
, pp. 128-140
-
-
Soballe, K.1
Rasmussen, H.B.2
Hansen, E.S.3
Buenger, C.4
-
4
-
-
0006298910
-
Effect of solubility of calcium phosphate coatings on mechanical fixation of porous ingrown implants
-
J. Beight, S.R. Radin, J. Cuckler, and P. Ducheyne, Effect of Solubility of Calcium Phosphate Coatings on Mechanical Fixation of Porous Ingrown Implants, Trans. 35th Annual Meeting Orthop. Res. Soc., Vol 14, 1989, p 334-342
-
(1989)
Trans. 35th Annual Meeting Orthop. Res. Soc.
, vol.14
, pp. 334-342
-
-
Beight, J.1
Radin, S.R.2
Cuckler, J.3
Ducheyne, P.4
-
5
-
-
1842297032
-
Shear and tensile strength of hydroxyapatite coating under loading conditions. An experimental study in dogs
-
R.T. Müller and T. Patsalis, Shear and Tensile Strength of Hydroxyapatite Coating under Loading Conditions. An Experimental Study in Dogs, Arch. Orthop. Trauma Surg., Vol 116, 1997, p 334-337
-
(1997)
Arch. Orthop. Trauma Surg.
, vol.116
, pp. 334-337
-
-
Müller, R.T.1
Patsalis, T.2
-
7
-
-
0000537655
-
Biocerarnic coatings: State-of-the-art and recent development trends
-
R.B. Heimann, T.A. Vu, and M.L. Wayman, Biocerarnic Coatings: State-of-the-Art and Recent Development Trends, Eur. J. Mineral., Vol 9, 1997, p 597-615
-
(1997)
Eur. J. Mineral.
, vol.9
, pp. 597-615
-
-
Heimann, R.B.1
Vu, T.A.2
Wayman, M.L.3
-
8
-
-
0028374717
-
Thermal decomposition of hydroxyapatite structure induced by titanium and its dioxide
-
J. Weng, X. Liu, X. Zhang, and X. Ji, Thermal Decomposition of Hydroxyapatite Structure Induced by Titanium and its Dioxide, J. Mater. Sci. Lett., Vol 13, 1994, p 159-161
-
(1994)
J. Mater. Sci. Lett.
, vol.13
, pp. 159-161
-
-
Weng, J.1
Liu, X.2
Zhang, X.3
Ji, X.4
-
9
-
-
2142817880
-
Microstructural characterization of hydroxyapatite coatings on titanium
-
H. Ji, C.B. Ponton, and P.M. Marquis, Microstructural Characterization of Hydroxyapatite Coatings on Titanium, J. Mater. Sci.: Mater. Med., Vol 3, 1992, p 283-287
-
(1992)
J. Mater. Sci.: Mater. Med.
, vol.3
, pp. 283-287
-
-
Ji, H.1
Ponton, C.B.2
Marquis, P.M.3
-
10
-
-
0029360622
-
Chromium accumulation and ultrastructural changes in the mouse liver by stainless steel corrosion products
-
M.L. Pereira, A.M. Abreu, J.P. Sousa, and G.S. Carvalho, Chromium Accumulation and Ultrastructural Changes in the Mouse Liver by Stainless Steel Corrosion Products, J. Mater. Sci.: Mater. Med., Vol 6, 1995, p 523-527
-
(1995)
J. Mater. Sci.: Mater. Med.
, vol.6
, pp. 523-527
-
-
Pereira, M.L.1
Abreu, A.M.2
Sousa, J.P.3
Carvalho, G.S.4
-
11
-
-
0030150670
-
Effect of CoCr corrosion products and corresponding separate metal ions on human osteoblast-like cell cultures
-
H. Tomas, G.S. Carvalho, M.H. Fernandes, A.P. Freire, and L.M. Abrantes, Effect of CoCr Corrosion Products and Corresponding Separate Metal Ions on Human Osteoblast-Like Cell Cultures, J. Mater. Sci.: Mater. Med., Vol 7, 1996, p 291-296
-
(1996)
J. Mater. Sci.: Mater. Med.
, vol.7
, pp. 291-296
-
-
Tomas, H.1
Carvalho, G.S.2
Fernandes, M.H.3
Freire, A.P.4
Abrantes, L.M.5
-
12
-
-
0001736571
-
Trace metals and chronic diseases
-
H.A. Schroeder, Trace Metals and Chronic Diseases, Adv. Int. Med., Vol 8, 1965, p 159-303
-
(1965)
Adv. Int. Med.
, vol.8
, pp. 159-303
-
-
Schroeder, H.A.1
-
13
-
-
0027381478
-
Hydroxyapatite ceramics for bone implant fixation. Mechanical and histological studies in dogs
-
58 pages
-
K. Soballe, Hydroxyapatite Ceramics for Bone Implant Fixation. Mechanical and Histological Studies in Dogs, Acta Orthop. Scand., Vol 64 (No. 255), 1993, 58 pages
-
(1993)
Acta Orthop. Scand.
, vol.64
, Issue.255
-
-
Soballe, K.1
-
14
-
-
0024212201
-
The effect of plasma-sprayed calcium phosphate ceramic coatings on metal ion release from porous titanium and cobalt-chromium alloy
-
P. Ducheyne and K.E. Healy, The Effect of Plasma-Sprayed Calcium Phosphate Ceramic Coatings on Metal Ion Release from Porous Titanium and Cobalt-Chromium Alloy, J. Biomed. Mater. Res., Vol 22, 1988, p 1137-1163
-
(1988)
J. Biomed. Mater. Res.
, vol.22
, pp. 1137-1163
-
-
Ducheyne, P.1
Healy, K.E.2
-
15
-
-
0029616612
-
The effect of hydroxyapatite thickness on metal ions release from stainless steel substrates
-
S.R. Sousa and M.A. Barbosa, The Effect of Hydroxyapatite Thickness on Metal Ions Release from Stainless Steel Substrates, J. Mater. Sci.: Mater. Med., Vol 6, 1995, p 818-823
-
(1995)
J. Mater. Sci.: Mater. Med.
, vol.6
, pp. 818-823
-
-
Sousa, S.R.1
Barbosa, M.A.2
-
16
-
-
0029583899
-
Modification in the molecular structure of hydroxyapatite induced by titanium ions
-
C.C. Ribeiro, M.A. Barbosa, A.A.S.C. Machado, A. Tudor, and M.C. Davies, Modification in the Molecular Structure of Hydroxyapatite Induced by Titanium Ions, J. Mater. Sci: Mater. Med., Vol 6, 1995, p 829-834
-
(1995)
J. Mater. Sci: Mater. Med.
, vol.6
, pp. 829-834
-
-
Ribeiro, C.C.1
Barbosa, M.A.2
Machado, A.A.S.C.3
Tudor, A.4
Davies, M.C.5
-
17
-
-
0030110085
-
The influence of plasma spraying parameters on the characteristics of hydroxyapatite coatings: A quantitative study
-
C.Y. Yang, B.C. Wang, W.J. Chang, E. Chang, and J.D. Wu, The Influence of Plasma Spraying Parameters on the Characteristics of Hydroxyapatite Coatings: A Quantitative Study, J. Mater, Sci.: Mater. Med., Vol 7, 1996, p 167-174
-
(1996)
J. Mater, Sci.: Mater. Med.
, vol.7
, pp. 167-174
-
-
Yang, C.Y.1
Wang, B.C.2
Chang, W.J.3
Chang, E.4
Wu, J.D.5
-
18
-
-
0026599431
-
Enhanced ingrowth of porous-coated CoCr implants plasma-sprayed with tricalcium phosphate
-
J.C. Chae, J.P. Collier, M.B. Mayor, V.A. Surprenant, and L.A. Dauphinais, Enhanced Ingrowth of Porous-Coated CoCr Implants Plasma-Sprayed with Tricalcium Phosphate, J. Biomed. Mater. Res., Vol 26, 1992, p 93-102
-
(1992)
J. Biomed. Mater. Res.
, vol.26
, pp. 93-102
-
-
Chae, J.C.1
Collier, J.P.2
Mayor, M.B.3
Surprenant, V.A.4
Dauphinais, L.A.5
-
19
-
-
0023471993
-
The effect of surface macrotexture and hydroxyapatite coating on the mechanical strength and histological profiles of titanium implant materials
-
K.A. Thomas, J.F. Kay, S.D. Cook, and M. Jarcho, The Effect of Surface Macrotexture and Hydroxyapatite Coating on the Mechanical Strength and Histological Profiles of Titanium Implant Materials, J. Biomed. Mater. Res., Vol 21, 1987, p 395-414
-
(1987)
J. Biomed. Mater. Res.
, vol.21
, pp. 395-414
-
-
Thomas, K.A.1
Kay, J.F.2
Cook, S.D.3
Jarcho, M.4
-
20
-
-
0028381904
-
The effect of plasma-sprayed coatings on the fatigue of titanium alloy implants
-
Feb
-
T. Smith, The Effect of Plasma-Sprayed Coatings on the Fatigue of Titanium Alloy Implants, J. Mater., Feb 1994, p 54-56
-
(1994)
J. Mater.
, pp. 54-56
-
-
Smith, T.1
-
21
-
-
0023499767
-
Chemical implant fixation using hydroxyapatite coatings
-
R.G.T. Geesink, K. de Groot, and C.P.A.T. Klein, Chemical Implant Fixation Using Hydroxyapatite Coatings, Clin. Orthop. Rel. Res., Vol 225, 1987, p 147-170
-
(1987)
Clin. Orthop. Rel. Res.
, vol.225
, pp. 147-170
-
-
Geesink, R.G.T.1
De Groot, K.2
Klein, C.P.A.T.3
-
22
-
-
0030109339
-
Hydroxyapatite coatings with a bond coat on biomedical implants by plasma projection
-
D. Lamy, A.C. Pierre, and R.B. Heimann, Hydroxyapatite Coatings with a Bond Coat on Biomedical Implants by Plasma Projection, J. Mater. Res., Vol 11 (No. 3), 1996, p 680-686
-
(1996)
J. Mater. Res.
, vol.11
, Issue.3
, pp. 680-686
-
-
Lamy, D.1
Pierre, A.C.2
Heimann, R.B.3
-
23
-
-
0025513446
-
2-based glasses: In vitro evaluation
-
2-Based Glasses: In Vitro Evaluation, J. Mater. Sci.: Mater. Med., Vol 1, 1990, p 239-244
-
(1990)
J. Mater. Sci.: Mater. Med.
, vol.1
, pp. 239-244
-
-
Ebisawa, Y.1
Kokubo, T.2
Ohura, K.3
Yamamuro, T.4
-
24
-
-
0014951015
-
Silicon: A possible factor in bone calcification
-
16 Jan
-
E.M. Carlisle, Silicon: A Possible Factor in Bone Calcification, Science, Vol 167, 16 Jan 1970, p 279-280
-
(1970)
Science
, vol.167
, pp. 279-280
-
-
Carlisle, E.M.1
-
25
-
-
0342854765
-
-
2nd book (in Japanese)
-
K. Ogawa, N. Nagata, and T. Yogoro, Onoda Res. Rep., Vol 43, 2nd book (No. 125), 1991, p 46-54 (in Japanese)
-
(1991)
Onoda Res. Rep.
, vol.43
, Issue.125
, pp. 46-54
-
-
Ogawa, K.1
Nagata, N.2
Yogoro, T.3
-
26
-
-
0028500109
-
Residual stress measurements in thermal sprayed hydroxyapatite coatings
-
S.R. Brown, I.G. Turner, and H. Reiter, Residual Stress Measurements in Thermal Sprayed Hydroxyapatite Coatings, J. Mater. Sci.: Mater. Med., Vol 5, 1994, p 756-759
-
(1994)
J. Mater. Sci.: Mater. Med.
, vol.5
, pp. 756-759
-
-
Brown, S.R.1
Turner, I.G.2
Reiter, H.3
-
27
-
-
0031972702
-
Adhesion of thermally sprayed hydroxyapatite-bond-coat systems measured by a novel peel test
-
H. Kurzweg, T. Troczynski, and R.B. Heimann, Adhesion of Thermally Sprayed Hydroxyapatite-Bond-Coat Systems Measured by a Novel Peel Test, J. Mater. Sci.: Mater. Med., Vol 9, 1998, p 9-16
-
(1998)
J. Mater. Sci.: Mater. Med.
, vol.9
, pp. 9-16
-
-
Kurzweg, H.1
Troczynski, T.2
Heimann, R.B.3
-
28
-
-
0032143828
-
Development of plasma-sprayed bioceramic coatings with bond coats based on titania and zirconia
-
H. Kurzweg, R.B. Heimann, T. Troczynski, and M.L. Wayman, Development of Plasma-Sprayed Bioceramic Coatings with Bond Coats Based on Titania and Zirconia, Biomaterials, Vol 19, 1998, p 1507-1511
-
(1998)
Biomaterials
, vol.19
, pp. 1507-1511
-
-
Kurzweg, H.1
Heimann, R.B.2
Troczynski, T.3
Wayman, M.L.4
-
29
-
-
1442330326
-
Hydroxyapatite-bond coat systems for improved mechanical and biological performance of hip implants
-
C. Coddet, Ed., 25-29 May Nice, France
-
R.B. Heimann, H. Kurzweg, and T.A. Vu, Hydroxyapatite-Bond Coat Systems for Improved Mechanical and Biological Performance of Hip Implants, Thermal Spray: Meeting the Challenges of the 21st Century, C. Coddet, Ed., 25-29 May 1998, Nice, France, p 999-1005
-
(1998)
Thermal Spray: Meeting the Challenges of the 21st Century
, pp. 999-1005
-
-
Heimann, R.B.1
Kurzweg, H.2
Vu, T.A.3
-
30
-
-
0028467481
-
Formation of hydroxyapatite on pure titanium substrates by ion beam dynamic mixing
-
O. Ohtsuka, M. Matsura, N. Chida, M. Yoshinori, T. Sumii, and T. Dérand, Formation of Hydroxyapatite on Pure Titanium Substrates by Ion Beam Dynamic Mixing, Surf. Coat. Technol., Vol 65, 1994, p 224-230
-
(1994)
Surf. Coat. Technol.
, vol.65
, pp. 224-230
-
-
Ohtsuka, O.1
Matsura, M.2
Chida, N.3
Yoshinori, M.4
Sumii, T.5
Dérand, T.6
-
32
-
-
0028749270
-
Peel adhesion test for thermal sprayed coatings
-
M. Sexsmith and T. Troczynski, Peel Adhesion Test for Thermal Sprayed Coatings, J.Therm. Spray Technol., Vol 3 (No. 4), 1994, p 404-409
-
(1994)
J.Therm. Spray Technol.
, vol.3
, Issue.4
, pp. 404-409
-
-
Sexsmith, M.1
Troczynski, T.2
-
33
-
-
0019654012
-
Peel analysis using the finite element method
-
A.D. Crocombe and R.D. Adams, Peel Analysis Using the Finite Element Method, J. Adhes., Vol 12, 1981, p 127-139
-
(1981)
J. Adhes.
, vol.12
, pp. 127-139
-
-
Crocombe, A.D.1
Adams, R.D.2
-
34
-
-
0013612513
-
Material properties of hydroxylapatite ceramics
-
G. Willmann, Material Properties of Hydroxylapatite Ceramics, Interceram, Vol 42 (No. 4), 1993, p 206-208
-
(1993)
Interceram
, vol.42
, Issue.4
, pp. 206-208
-
-
Willmann, G.1
-
35
-
-
0030408924
-
Residual stresses in thermal spray coatings and their effect on interfacial adhesion: A review of recent work
-
T.W. Clyne and S.C. Gill, Residual Stresses in Thermal Spray Coatings and Their Effect on Interfacial Adhesion: A Review of Recent Work, J. Therm. Spray Technol., Vol 5 (No. 4), 1996, p 401-418
-
(1996)
J. Therm. Spray Technol.
, vol.5
, Issue.4
, pp. 401-418
-
-
Clyne, T.W.1
Gill, S.C.2
-
36
-
-
0023502204
-
Plasma-sprayed coatings of hydroxyl-apatite
-
K. de Groot, R.T.G. Geesink, C.P.A.T. Klein, and P. Serekian, Plasma-Sprayed Coatings of Hydroxyl-Apatite, J. Biomed. Mater. Res., Vol 21, 1987, p 1375-1381
-
(1987)
J. Biomed. Mater. Res.
, vol.21
, pp. 1375-1381
-
-
De Groot, K.1
Geesink, R.T.G.2
Klein, C.P.A.T.3
Serekian, P.4
-
37
-
-
0031077218
-
-
J. Weng, Q. Liu, J.G.C. Wolke, D. Zhang, and K. de Groot, J. Mater. Sci. Lett., Vol 16, 1997, p 335-337
-
(1997)
J. Mater. Sci. Lett.
, vol.16
, pp. 335-337
-
-
Weng, J.1
Liu, Q.2
Wolke, J.G.C.3
Zhang, D.4
De Groot, K.5
-
38
-
-
0003034298
-
Substrate surface dissolution and interfacial biological mineralization
-
J.E. Davies, Ed., University of Toronto Press
-
R.Z. LeGeros, I. Orly, M. Gregoire, and G. Dalcusi, Substrate Surface Dissolution and Interfacial Biological Mineralization, The Bone-Biomaterial Interface, J.E. Davies, Ed., University of Toronto Press, 1991, p 76-88
-
(1991)
The Bone-biomaterial Interface
, pp. 76-88
-
-
LeGeros, R.Z.1
Orly, I.2
Gregoire, M.3
Dalcusi, G.4
-
39
-
-
0024405060
-
Solution-mediated transformation of octacalcium phosphate (OCP) to apatite
-
R.Z. LeGeros, G. Dalcusi, I. Orly, T. Abergas, and W. Torres, Solution-Mediated Transformation of Octacalcium Phosphate (OCP) to Apatite, Scan. Microsc., Vol 3, 1989, p 129-138
-
(1989)
Scan. Microsc.
, vol.3
, pp. 129-138
-
-
LeGeros, R.Z.1
Dalcusi, G.2
Orly, I.3
Abergas, T.4
Torres, W.5
|