Volumn 44, Issue 4, 1999, Pages 257-270

Composition of mortar as a function of distance to the brick-mortar interface: A study on the formation of cured mortar structure in masonry using NMR, PFM and XRD

Author keywords

[No Author keywords available]

Indexed keywords

BINDERS; BRICK; CARBONATION; CURING; INTERFACES (MATERIALS); MECHANICAL PERMEABILITY; MORTAR; NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY; OPTICAL MICROSCOPY; X RAY DIFFRACTION ANALYSIS;

EID: 0033282794     PISSN: 00467316     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (5)

References (12)
  • 1
    • 0342609939 scopus 로고    scopus 로고
    • Moisture transport in brick masonry: the grey area between bricks Ph.D. thesis, Eindhoven University of Technology, The Netherlands
    • BROCKEN H.J.P., Moisture transport in brick masonry: the grey area between bricks Ph.D. thesis, Eindhoven University of Technology, The Netherlands (1998),
    • (1998)
    • Brocken, H.J.P.1
  • 2
    • 0342609938 scopus 로고    scopus 로고
    • Influence of the macro & microstructure of air entrained mortars on masonry bond strength
    • SUGO H.O., PAGE A.W. and LAWRENCE S.J., Influence of the macro & microstructure of air entrained mortars on masonry bond strength, Proc. 7th N. Am. Mas. Conf., 230-241 (1996).
    • (1996) Proc. 7th N. Am. Mas. Conf. , pp. 230-241
    • Sugo, H.O.1    Page, A.W.2    Lawrence, S.J.3
  • 3
    • 0000146410 scopus 로고
    • One-dimensional scanning of moisture in porous materials with NMR
    • KOPINGA K. and PEL L., One-dimensional scanning of moisture in porous materials with NMR, Rev. Sci. Instrum. 65, 3673-3681 (1994).
    • (1994) Rev. Sci. Instrum. , vol.65 , pp. 3673-3681
    • Kopinga, K.1    Pel, L.2
  • 6
    • 0343479955 scopus 로고
    • Standard test method for microscopical determination of parameters of the air-void system in hardened concrete
    • American Society for Testing and Materials, ASTM Standard C457-95 "Standard Test Method for Microscopical Determination of Parameters of the Air-Void System in Hardened Concrete", 229-241 (1995).
    • (1995) ASTM Standard C457-95 , pp. 229-241
  • 9
    • 0343044104 scopus 로고    scopus 로고
    • Composition of cement-lime and cement mortar as a function of distance to the brick-mortar interface: Consequences for masonry
    • submitted for publication
    • BROCKEN HJ.P., PERS N.M. VAN DER and LARBI J.A., Composition of cement-lime and cement mortar as a function of distance to the brick-mortar interface: consequences for masonry, submitted for publication in Mater. Struct. (1999).
    • (1999) Mater. Struct.
    • Brocken, H.J.P.1    Van Der Pers, N.M.2    Larbi, J.A.3
  • 12
    • 0025491019 scopus 로고
    • Effects of water-cement ratio, quantity and fineness of sand on the evolution of lime in set portland cement systems
    • LARBI J.A., BIJEN J.M.J.M., Effects of water-cement ratio, quantity and fineness of sand on the evolution of lime in set portland cement systems, Cem. Con. Res. 20, 783-794 (1990).
    • (1990) Cem. Con. Res. , vol.20 , pp. 783-794
    • Larbi, J.A.1    Bijen, J.M.J.M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.