Monte Carlo simulation of the radiographic imaging procedure for electronically designed phantoms

Author keywords

[No Author keywords available]

Indexed keywords

APPLICATION PROGRAMS; COMPUTER AIDED SOFTWARE ENGINEERING; GEOMETRY; INTELLIGENT SYSTEMS; IRRADIATION; PHANTOMS; X RAY RADIOGRAPHY;

EID: 0033250159     PISSN: 09269630     EISSN: 18798365     Source Type: Book Series    
DOI: 10.3233/978-1-60750-912-7-391     Document Type: Conference Paper
Times cited : (1)

References (10)
  • 1
    • 0025730909 scopus 로고
    • Monte carlo techniques in medical radiation physics
    • Andreo P, 1991, Monte Carlo techniques in medical radiation physics, Phys. Med. Biol. 36 861-920.
    • (1991) Phys. Med. Biol. , vol.36 , pp. 861-920
    • Andreo, P.1
  • 2
    • 0029015235 scopus 로고
    • The physical performance of different X-ray contrast agents: Calculations using a monte carlo code of the imaging chain
    • Sandborg M, Christoffersson J-O, Carlsson GA, Almen T and Dance DR, 1995, The physical performance of different X-ray contrast agents: calculations using a Monte Carlo code of the imaging chain, Phys.Med.Biol. 40, 1209-1224
    • (1995) Phys.Med.Biol. , vol.40 , pp. 1209-1224
    • Sandborg, M.1    Christoffersson, J.-O.2    Carlsson, G.A.3    Almen, T.4    Dance, D.R.5
  • 3
    • 0021138762 scopus 로고
    • Radiation dose in diagnostic radiology: Monte carlo simulation studies
    • Chan H P and Doi K, 1984, Radiation dose in diagnostic radiology: Monte Carlo simulation studies, Med. Phys. 11, 480-490.
    • (1984) Med. Phys. , vol.11 , pp. 480-490
    • Chan, H.P.1    Doi, K.2
  • 4
    • 0021224747 scopus 로고
    • The computation of scatter in mammography by monte carlo methods
    • Dance D R and Day G J 1983 The computation of scatter in mammography by Monte Carlo methods, Phys. Med. Biol. 29, 237-247
    • (1983) Phys. Med. Biol. , vol.29 , pp. 237-247
    • Dance, D.R.1    Day, G.J.2
  • 6
    • 0026923449 scopus 로고
    • Solid geometry based object model for monte carlo simulated emission and transmission tomographic imaging systems
    • Wang H, Jaczszak RJ and Coleman RE, 1992, Solid geometry based object model for Monte Carlo simulated emission and transmission tomographic imaging systems, IEEE Trans, Med. Imaging MI-11 361-372.
    • (1992) IEEE Trans, Med Imaging MI-11 , pp. 361-372
    • Wang, H.1    Jaczszak, R.J.2    Coleman, R.E.3
  • 7
    • 0025756532 scopus 로고
    • Semiempirical model for generating tungsten target X-ray spectra
    • Tucker D M, Barnes G T, Chakraborty D P, 1991, Semiempirical model for generating tungsten target X-ray spectra. Med. Phys. 18 211-218
    • (1991) Med. Phys. , vol.18 , pp. 211-218
    • Tucker, D.M.1    Barnes, G.T.2    Chakraborty, D.P.3
  • 9
    • 0031716007 scopus 로고    scopus 로고
    • Measured molecular coherent scattering form factors of animal tissues, plastics and human breast tissue
    • Peplow E D and Verghese K, 1998, Measured molecular coherent scattering form factors of animal tissues, plastics and human breast tissue. Phys. Med. Biol. 43 2431-2452.
    • (1998) Phys. Med. Biol. , vol.43 , pp. 2431-2452
    • Peplow, E.D.1    Verghese, K.2
  • 10
    • 0023792394 scopus 로고
    • An analytical model of scattered radiation distribution in diagnostic radiology
    • Boone J and Seibert A, 1988, An analytical model of scattered radiation distribution in diagnostic radiology Med. Phys. 15 721-25.
    • (1988) Med Phys. , vol.15 , pp. 721-725
    • Boone, J.1    Seibert, A.2