A simple method for the correction of distorted digital angiographic images for stereotactic target localization

Author keywords

Digital subtraction angiography; Distortion; Stereotactic localization

Indexed keywords

ARTERIOVENOUS MALFORMATION; ARTICLE; COMPUTER PROGRAM; DIAGNOSTIC ACCURACY; DIGITAL SUBTRACTION ANGIOGRAPHY; IMAGE INTENSIFIER; IMAGE QUALITY; PHANTOM; PRIORITY JOURNAL; TREATMENT PLANNING;

EID: 0033231598     PISSN: 12783218     EISSN: None     Source Type: Journal    
DOI: 10.1016/S1278-3218(00)88256-6     Document Type: Article
Times cited : (4)

References (6)
  • 1
    • 0022591943 scopus 로고
    • A method of stereotactic localization adopted for conventional and digital radiography
    • Bergstrom M, Greitz T, Ribbe T. A method of stereotactic localization adopted for conventional and digital radiography. Neuroradiology 1986; 28 : 100-4.
    • (1986) Neuroradiology , vol.28 , pp. 100-104
    • Bergstrom, M.1    Greitz, T.2    Ribbe, T.3
  • 2
    • 0023234713 scopus 로고
    • Image intensifier distortion correction
    • Chakraborty DP. Image intensifier distortion correction. Med Phys 1987; 14 : 249-52.
    • (1987) Med Phys , vol.14 , pp. 249-252
    • Chakraborty, D.P.1
  • 3
    • 0031455395 scopus 로고    scopus 로고
    • The accuracy and reproducibility of a global method to correct the geometric image distortion in the x-ray image chain
    • Gronenschild E. The accuracy and reproducibility of a global method to correct the geometric image distortion in the x-ray image chain. Med Phys 1997; 24 : 1875-88.
    • (1997) Med Phys , vol.24 , pp. 1875-1888
    • Gronenschild, E.1
  • 4
    • 0030756443 scopus 로고    scopus 로고
    • Design, construction and installation of a new stereotactic system for single dose and fractionated radiotherapy
    • Kappas C, Theodorou K, Kardamakis D, Maraziotis T, Dimopoulos I, Papadakis I, et al. Design, construction and installation of a new stereotactic system for single dose and fractionated radiotherapy. Physica Medica 1997; 13 : 123-8.
    • (1997) Physica Medica , vol.13 , pp. 123-128
    • Kappas, C.1    Theodorou, K.2    Kardamakis, D.3    Maraziotis, T.4    Dimopoulos, I.5    Papadakis, I.6
  • 5
    • 0025837262 scopus 로고
    • Accurate characterization of image intensifier distortion
    • Rubin S, Bednarek DR, Wong R. Accurate characterization of image intensifier distortion. Med Phys 1991; 18 : 1145-51.
    • (1991) Med Phys , vol.18 , pp. 1145-1151
    • Rubin, S.1    Bednarek, D.R.2    Wong, R.3
  • 6
    • 0026627887 scopus 로고
    • Correction of spatial distortion in magnetic resonance angiography for radiosurgical treatment planning of cerebral arteriovenous malformations
    • Schad LR, Ehricke HH, Wowra B, Layer G, Engenhart R, Kauczor HU, et al. Correction of spatial distortion in magnetic resonance angiography for radiosurgical treatment planning of cerebral arteriovenous malformations. Magn Reson Imaging 1992; 10 : 609-21.
    • (1992) Magn Reson Imaging , vol.10 , pp. 609-621
    • Schad, L.R.1    Ehricke, H.H.2    Wowra, B.3    Layer, G.4    Engenhart, R.5    Kauczor, H.U.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.