메뉴 건너뛰기




Volumn 56, Issue 5-6, 1999, Pages 535-537

Effect of collimator size and absorber thickness on gamma ray attenuation measurements

Author keywords

Attenuation coefficient; Collimator size; Correlation effect; Multiple scattering

Indexed keywords

ATTENUATION; OPTICAL COLLIMATORS; SCATTERING; SOILS; WATER;

EID: 0033230268     PISSN: 0969806X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0969-806X(99)00341-2     Document Type: Article
Times cited : (24)

References (4)
  • 1
    • 0015786147 scopus 로고
    • A method to determine the Gamma ray attenuation coefficient
    • Gopal S., Sanjeevaiah B. A method to determine the Gamma ray attenuation coefficient. Nucl. Instrum. Methods. 107:1973;221.
    • (1973) Nucl. Instrum. Methods , vol.107 , pp. 221
    • Gopal, S.1    Sanjeevaiah, B.2
  • 2
    • 0020213666 scopus 로고
    • Photon mass attenuation and energy-absorption coefficients from 1 keV to 20 MeV
    • Hubbell J.H. Photon mass attenuation and energy-absorption coefficients from 1 keV to 20 MeV. Int. J. Appl. Radiat. Isot. 33:1982;1269.
    • (1982) Int. J. Appl. Radiat. Isot. , vol.33 , pp. 1269
    • Hubbell, J.H.1
  • 3
    • 0343727198 scopus 로고
    • Effect of sample thickness on the measured mass attenuation coefficients of perspex and bakelite
    • Singh M., Mudahar G.S. Effect of sample thickness on the measured mass attenuation coefficients of perspex and bakelite. I. J. Phys. 67A:1993;79.
    • (1993) I. J. Phys. , vol.67 , pp. 79
    • Singh, M.1    Mudahar, G.S.2
  • 4
    • 0342856745 scopus 로고
    • Effect of finite absorber dimensions on Gamma ray attenuation measurements
    • Varier K.M., Kunju S.N., Madhusudanan K. Effect of finite absorber dimensions on Gamma ray attenuation measurements. Phys. Rev. A. 33:1986;2378.
    • (1986) Phys. Rev. a , vol.33 , pp. 2378
    • Varier, K.M.1    Kunju, S.N.2    Madhusudanan, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.