메뉴 건너뛰기




Volumn 70, Issue 10, 1999, Pages 641-645

What is the oxygen environment under an encapsulated segment bifocal RGP contact lens?

Author keywords

Bifocal; Contact lens; Encapsulated segment; Hypoxia; Presbyopia; Transmissibility

Indexed keywords

OXYGEN; POLY(METHYL METHACRYLATE);

EID: 0033211326     PISSN: 15291839     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (4)

References (31)
  • 1
    • 0023430530 scopus 로고
    • Histopathological analysis of the corneal epithelium after contact lens wear
    • Bergmanson JPG. Histopathological analysis of the corneal epithelium after contact lens wear. J AM OPTOM ASSOC 1987;58:812-8.
    • (1987) J AM OPTOM ASSOC , vol.58 , pp. 812-818
    • Bergmanson, J.P.G.1
  • 2
    • 0022459857 scopus 로고
    • Influence of wearing schedule on extended wear complications
    • Kenyon E, Poise KA, Seger RG. Influence of wearing schedule on extended wear complications. Ophthalmology 1986;93:231-6.
    • (1986) Ophthalmology , vol.93 , pp. 231-236
    • Kenyon, E.1    Poise, K.A.2    Seger, R.G.3
  • 3
    • 0018578830 scopus 로고
    • Problems associated with prolonged wear soft contact lenses
    • Kaufman HE. Problems associated with prolonged wear soft contact lenses. Ophthalmology 1979; 86:411-7.
    • (1979) Ophthalmology , vol.86 , pp. 411-417
    • Kaufman, H.E.1
  • 5
    • 0026756652 scopus 로고
    • Corneal exhaustion syndrome with long-term wear of contact lenses
    • Sweeney DF. Corneal exhaustion syndrome with long-term wear of contact lenses. Optom Vis Sci 1992;69:601-8.
    • (1992) Optom Vis Sci , vol.69 , pp. 601-608
    • Sweeney, D.F.1
  • 6
    • 0028221588 scopus 로고
    • The relation between contact lens oxygen transmissibility and binding of Pseudomonas aeruginosa to the cornea after overnight wear
    • Imayasu M, Petroll WM, Jester JV, et al. The relation between contact lens oxygen transmissibility and binding of Pseudomonas aeruginosa to the cornea after overnight wear. Ophthalmology 1994;101:371-88.
    • (1994) Ophthalmology , vol.101 , pp. 371-388
    • Imayasu, M.1    Petroll, W.M.2    Jester, J.V.3
  • 7
    • 0025892553 scopus 로고
    • Corneal response to different oxygen levels during extended wear
    • Rivera RK, Polse KA. Corneal response to different oxygen levels during extended wear. CLAO J 1991;17:96-101.
    • (1991) CLAO J , vol.17 , pp. 96-101
    • Rivera, R.K.1    Polse, K.A.2
  • 8
    • 0019731768 scopus 로고
    • Stromal lactate accumulation can account for corneal edema osmotically following eptihelial hypoxia in the rabbit
    • Klyce SD. Stromal lactate accumulation can account for corneal edema osmotically following eptihelial hypoxia in the rabbit. J Physiol 1981;321:49-64.
    • (1981) J Physiol , vol.321 , pp. 49-64
    • Klyce, S.D.1
  • 10
    • 0025126423 scopus 로고
    • Corneal hypoxia and hypercapnia during contact lens wear
    • Efron N, Ang JHB. Corneal hypoxia and hypercapnia during contact lens wear. Optom Vis Sci 1990;67:512-21.
    • (1990) Optom Vis Sci , vol.67 , pp. 512-521
    • Efron, N.1    Ang, J.H.B.2
  • 11
    • 0039246095 scopus 로고
    • Corneal oxygen consumption and hypoxia
    • Bennet ES, Weissman BA, eds. (Chapter 7). Philadelphia: JB Lippincott Company
    • Efron N, Brennan NA. Corneal oxygen consumption and hypoxia. In: Bennet ES, Weissman BA, eds. Clinical contact lens practice (Chapter 7). Philadelphia: JB Lippincott Company, 1994:1-14.
    • (1994) Clinical Contact Lens Practice , pp. 1-14
    • Efron, N.1    Brennan, N.A.2
  • 12
    • 0022201849 scopus 로고
    • Effects of long-term extended contact lens wear on the human cornea
    • Holden BA, Sweeney D, Vannas A, et al. Effects of long-term extended contact lens wear on the human cornea. Invest Ophthalmol Vis Sci 1985;26:1489-501.
    • (1985) Invest Ophthalmol Vis Sci , vol.26 , pp. 1489-1501
    • Holden, B.A.1    Sweeney, D.2    Vannas, A.3
  • 13
    • 0025337466 scopus 로고
    • Contact lens-induced edema in vitro
    • Huff JW. Contact lens-induced edema in vitro. Invest Ophthalmol Vis Sci 1990;31:1288-93.
    • (1990) Invest Ophthalmol Vis Sci , vol.31 , pp. 1288-1293
    • Huff, J.W.1
  • 14
    • 0014862075 scopus 로고
    • Critical oxygen tension at the corneal surface
    • Poise KA, Mandell RB. Critical oxygen tension at the corneal surface. Arch Ophthalmol 1970;84:505-8.
    • (1970) Arch Ophthalmol , vol.84 , pp. 505-508
    • Poise, K.A.1    Mandell, R.B.2
  • 16
    • 0024533269 scopus 로고
    • Corneal endothelial changes associated with contact lens wear
    • MacRae S, Matsuda M, Shellans S. Corneal endothelial changes associated with contact lens wear. CLAO J 1989;15:82-7.
    • (1989) CLAO J , vol.15 , pp. 82-87
    • MacRae, S.1    Matsuda, M.2    Shellans, S.3
  • 17
    • 0030111045 scopus 로고    scopus 로고
    • Contact lens transmissibility: Effects on delivery of oxygen to the cornea
    • Ostrem ED, Fink BA, Hill RM. Contact lens transmissibility: effects on delivery of oxygen to the cornea. Optom Vis Sci 1996;73;159-63.
    • (1996) Optom Vis Sci , vol.73 , pp. 159-163
    • Ostrem, E.D.1    Fink, B.A.2    Hill, R.M.3
  • 18
    • 0017596705 scopus 로고
    • Tear film dynamics and oxygen tension under a circular contact lens
    • Allaire PE, Allison SW, Gooray AM. Tear film dynamics and oxygen tension under a circular contact lens. Am J Optom Physiol Optics 1977;54:617-26.
    • (1977) Am J Optom Physiol Optics , vol.54 , pp. 617-626
    • Allaire, P.E.1    Allison, S.W.2    Gooray, A.M.3
  • 19
    • 84990557310 scopus 로고
    • Models of oxygen performance for the static, dynamic, and closed lid wear of hydrogel contact lenses
    • Efron N, Carney LG. Models of oxygen performance for the static, dynamic, and closed lid wear of hydrogel contact lenses. Aust J Optom 1981;64:223-33.
    • (1981) Aust J Optom , vol.64 , pp. 223-233
    • Efron, N.1    Carney, L.G.2
  • 22
    • 38249002503 scopus 로고
    • Effects of prism ballasting of rigid contact lenses on human corneal oxygen-uptake rates. Part 1: Open eye conditions
    • Szczotka LB, Fink BA, Hill RM. Effects of prism ballasting of rigid contact lenses on human corneal oxygen-uptake rates. Part 1: Open eye conditions. Intern Contact Lens Clin 1993;20:155-9.
    • (1993) Intern Contact Lens Clin , vol.20 , pp. 155-159
    • Szczotka, L.B.1    Fink, B.A.2    Hill, R.M.3
  • 23
    • 0001209882 scopus 로고    scopus 로고
    • The oxygen environment under an encapsulated segment bifocal RGP contact lens under static conditions
    • Brunstetter TJ, Fink BA, Hill RM. The oxygen environment under an encapsulated segment bifocal RGP contact lens under static conditions. Optom Vis Sci 1997;74(12s):94.
    • (1997) Optom Vis Sci , vol.74 , Issue.12 S , pp. 94
    • Brunstetter, T.J.1    Fink, B.A.2    Hill, R.M.3
  • 26
    • 37049240646 scopus 로고
    • Oxygen uptake from a reservoir of limited volume by the human cornea in vivo
    • Hill RM, Fatt I. Oxygen uptake from a reservoir of limited volume by the human cornea in vivo. Science 1963;142:1295-7.
    • (1963) Science , vol.142 , pp. 1295-1297
    • Hill, R.M.1    Fatt, I.2
  • 27
    • 2842586619 scopus 로고
    • Oxygen depletion of a limited reservoir by human conjunctiva
    • Hill RM, Fatt I. Oxygen depletion of a limited reservoir by human conjunctiva. Nature 1963;202:1011-3.
    • (1963) Nature , vol.202 , pp. 1011-1013
    • Hill, R.M.1    Fatt, I.2
  • 28
    • 5844293744 scopus 로고
    • Oxygen uptake of the cornea following contact lens removal
    • Hill RM. Oxygen uptake of the cornea following contact lens removal. J AM OPTOM ASSOC 1965;36:913-5.
    • (1965) J Am Optom Assoc , vol.36 , pp. 913-915
    • Hill, R.M.1
  • 29
    • 0031204574 scopus 로고    scopus 로고
    • Corneal responses to lens transmissibility
    • Smith BJ, Fmk BA, Hill RM. Corneal responses to lens transmissibility. J AM OPTOM ASSOC 1997;68:478-82.
    • (1997) J Am Optom Assoc , vol.68 , pp. 478-482
    • Smith, B.J.1    Fmk, B.A.2    Hill, R.M.3
  • 30
    • 0033103614 scopus 로고    scopus 로고
    • The "physiologically effective' correlates: PeDk/L and peDk
    • Hill RM. The "physiologically effective' correlates: peDk/L and peDk. Optom Vis Sci 1999;76:135-40.
    • (1999) Optom Vis Sci , vol.76 , pp. 135-140
    • Hill, R.M.1
  • 31
    • 0021123317 scopus 로고
    • Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses
    • Holden BA, Mertz GW. Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses. Invest Ophthalmol Vis Sci 1984;25:1161-7.
    • (1984) Invest Ophthalmol Vis Sci , vol.25 , pp. 1161-1167
    • Holden, B.A.1    Mertz, G.W.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.