메뉴 건너뛰기




Volumn 39, Issue 10, 1999, Pages 865-869

Pulse tube refrigerator below 2 K

Author keywords

[No Author keywords available]

Indexed keywords

COMPRESSORS; CRYOGENICS; HELIUM; PRESSURE RELIEF VALVES; REFRIGERATION;

EID: 0033207857     PISSN: 00112275     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0011-2275(99)00101-0     Document Type: Article
Times cited : (61)

References (13)
  • 1
    • 43949150860 scopus 로고
    • Novel configuration of three-stage pulse tube refrigerator for temperatures below 4 K
    • Matsubara Y, Gao JL. Novel configuration of three-stage pulse tube refrigerator for temperatures below 4 K. Cryogenics 1994;34:259.
    • (1994) Cryogenics , vol.34 , pp. 259
    • Matsubara, Y.1    Gao, J.L.2
  • 2
    • 0342295165 scopus 로고    scopus 로고
    • Pulsröhrenkühler zur erzeugung von temperaturen im bereich des flüssigen heliums
    • Thummes G., Wang C., Bender S., Heiden C. Pulsröhrenkühler zur erzeugung von temperaturen im bereich des flüssigen heliums. DKV-Tagungsbericht. 23(Jahrgang Band I):1996;147-159.
    • (1996) DKV-Tagungsbericht , vol.23 , Issue.JAHRGANG BAND I , pp. 147-159
    • Thummes, G.1    Wang, C.2    Bender, S.3    Heiden, C.4
  • 3
    • 85031579002 scopus 로고    scopus 로고
    • 3He was pointed out by Giorgio Frossati in a private communication to us
    • 3He was pointed out by Giorgio Frossati in a private communication to us.
  • 7
    • 0032631563 scopus 로고    scopus 로고
    • Optimization of pulse tubes
    • De Waele A.T.A.M. Optimization of pulse tubes. Cryogenics. 39:1999;13.
    • (1999) Cryogenics , vol.39 , pp. 13
    • De Waele, A.T.A.M.1
  • 9
    • 0004063834 scopus 로고
    • Amsterdam: Elsevier
    • Keesom WH. Helium. Amsterdam: Elsevier, 1942.
    • (1942) Helium
    • Keesom, W.H.1
  • 12
    • 0025449111 scopus 로고
    • Double inlet pulse tube refrigerator: An important improvement
    • Zhu S.W., Wu P.Y., Chen Z.Q. Double inlet pulse tube refrigerator: an important improvement. Cryogenics. 30:1990;514.
    • (1990) Cryogenics , vol.30 , pp. 514
    • Zhu, S.W.1    Wu, P.Y.2    Chen, Z.Q.3
  • 13
    • 0000289753 scopus 로고    scopus 로고
    • Experimental study on a double orifice two-stage pulse tube refrigerator
    • Chen G., Qiu L., Zheng J.et al. Experimental study on a double orifice two-stage pulse tube refrigerator. Cryogenics. 37:1997;271.
    • (1997) Cryogenics , vol.37 , pp. 271
    • Chen, G.1    Qiu, L.2    Zheng, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.