메뉴 건너뛰기




Volumn 173, Issue 3, 1999, Pages 625-629

Perspective. Fine-needle transjugular intrahepatic portosystemic shunt procedure with CO2

Author keywords

[No Author keywords available]

Indexed keywords

ANESTHESIA COMPLICATION; HUMAN; PORTAL VEIN; PORTOSYSTEMIC ANASTOMOSIS; PRIORITY JOURNAL; REVIEW; SURGICAL APPROACH; SURGICAL TECHNIQUE; ARTICLE; DIGITAL SUBTRACTION ANGIOGRAPHY; INSTRUMENTATION; METHODOLOGY; NEEDLE;

EID: 0033192730     PISSN: 0361803X     EISSN: None     Source Type: Journal    
DOI: 10.2214/ajr.173.3.10470891     Document Type: Review
Times cited : (17)

References (13)
  • 1
    • 0030696196 scopus 로고    scopus 로고
    • Technical aspects of accessing the portal vein during the TIPS procedure
    • Saxon RR, Keller FS. Technical aspects of accessing the portal vein during the TIPS procedure. J Vasc Interv Radiol 1997;8:733-744
    • (1997) J Vasc Interv Radiol , vol.8 , pp. 733-744
    • Saxon, R.R.1    Keller, F.S.2
  • 2
    • 0027692096 scopus 로고
    • Complications of transjugular intrahepatic portosystemic shunt: A comprehensive review
    • Freedman AM, Sanyal AJ, Tisnado J, et al. Complications of transjugular intrahepatic portosystemic shunt: a comprehensive review. RadioGraphics 1993;13:1185-1210
    • (1993) RadioGraphics , vol.13 , pp. 1185-1210
    • Freedman, A.M.1    Sanyal, A.J.2    Tisnado, J.3
  • 3
    • 0027687907 scopus 로고
    • Puncture of the portal bifurcation: A fatal complication of TIPS
    • Rossle M. Puncture of the portal bifurcation: a fatal complication of TIPS (letter). RadioGraphics 1993;13:1184
    • (1993) RadioGraphics , vol.13 , pp. 1184
    • Rossle, M.1
  • 4
    • 0027164341 scopus 로고
    • Hepatic arterial injury after transjugular intrahepatic portosystemic shunt placement: Report of two cases
    • Haskal ZJ, Pentecost MJ, Rubin RA. Hepatic arterial injury after transjugular intrahepatic portosystemic shunt placement: report of two cases. Radiology 1993;188:85-88
    • (1993) Radiology , vol.188 , pp. 85-88
    • Haskal, Z.J.1    Pentecost, M.J.2    Rubin, R.A.3
  • 6
    • 0028884208 scopus 로고
    • Plastic bag delivery system for hand injection of carbon dioxide
    • Hawkins IF Jr, Caridi JG, Kerns SR. Plastic bag delivery system for hand injection of carbon dioxide. AJR 1995;165:1487-1489
    • (1995) AJR , vol.165 , pp. 1487-1489
    • Hawkins I.F., Jr.1    Caridi, J.G.2    Kerns, S.R.3
  • 8
    • 0027688969 scopus 로고
    • Histopathologic study of stenotic and occluded transjugular intrahepatic portosystemic shunts
    • LaBerge JM, Ferrell LD, Ring EJ, Gordon RL. Histopathologic study of stenotic and occluded transjugular intrahepatic portosystemic shunts. J Vasc Interv Radiol 1993;4:779-786
    • (1993) J Vasc Interv Radiol , vol.4 , pp. 779-786
    • LaBerge, J.M.1    Ferrell, L.D.2    Ring, E.J.3    Gordon, R.L.4
  • 9
    • 0030183810 scopus 로고    scopus 로고
    • Bile duct injury as a major cause of stenosis and occlusion in transjugular intrahepatic portosystemic shunts: Comparative histopathologic analysis in humans and swine
    • Saxon RR, Mendel-Hartvig J, Corless CL, et al. Bile duct injury as a major cause of stenosis and occlusion in transjugular intrahepatic portosystemic shunts: comparative histopathologic analysis in humans and swine. J Vasc Interv Radiol 1996;7:487-497
    • (1996) J Vasc Interv Radiol , vol.7 , pp. 487-497
    • Saxon, R.R.1    Mendel-Hartvig, J.2    Corless, C.L.3
  • 10
    • 0030659578 scopus 로고    scopus 로고
    • PTFE-encapsulated endovascular stent-graft for transjugular intrahepatic portosystemic shunts: Experimental evaluation
    • Haskal ZJ, Davis A, McAllister A, Furth EE. PTFE-encapsulated endovascular stent-graft for transjugular intrahepatic portosystemic shunts: experimental evaluation. Radiology 1997;205:682-688
    • (1997) Radiology , vol.205 , pp. 682-688
    • Haskal, Z.J.1    Davis, A.2    McAllister, A.3    Furth, E.E.4
  • 11
    • 0028397785 scopus 로고
    • Use of carbon dioxide as a contrast medium for transjugular intrahepatic portosystemic shunt procedures
    • Rees CR, Niblett RL, Lee SP, Diamond NG, Crippen JS. Use of carbon dioxide as a contrast medium for transjugular intrahepatic portosystemic shunt procedures. J Vasc Interv Radiol 1994;5:383-386
    • (1994) J Vasc Interv Radiol , vol.5 , pp. 383-386
    • Rees, C.R.1    Niblett, R.L.2    Lee, S.P.3    Diamond, N.G.4    Crippen, J.S.5
  • 12
    • 0029692637 scopus 로고    scopus 로고
    • Hepatic laceration from wedged venography performed before transjugular intrahepatic portosystemic shunt placement
    • Semba CP, Saperstein L, Nyman U, et al. Hepatic laceration from wedged venography performed before transjugular intrahepatic portosystemic shunt placement. J Vasc Interv Radiol 1996;7:143-146
    • (1996) J Vasc Interv Radiol , vol.7 , pp. 143-146
    • Semba, C.P.1    Saperstein, L.2    Nyman, U.3
  • 13
    • 0030610458 scopus 로고    scopus 로고
    • 2 digital subtraction angiography: Potential complications and their prevention
    • 2 digital subtraction angiography: potential complications and their prevention. J Vasc Interv Radiol 1997;8:383-391
    • (1997) J Vasc Interv Radiol , vol.8 , pp. 383-391
    • Caridi, J.G.1    Hawkins I.F., Jr.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.