메뉴 건너뛰기




Volumn 140, Issue 1, 1999, Pages 17-31

Error-Tolerant RF Litz Coils for NMR/MRI

Author keywords

Birdcage; Double resonance; Litz coil; Multinuclear

Indexed keywords

ARTICLE; EQUIPMENT DESIGN; HISTOLOGY; HUMAN; IMAGE PROCESSING; INSTRUMENTATION; NUCLEAR MAGNETIC RESONANCE IMAGING; NUCLEAR MAGNETIC RESONANCE SPECTROSCOPY; SPINE;

EID: 0033185617     PISSN: 10907807     EISSN: None     Source Type: Journal    
DOI: 10.1006/jmre.1999.1828     Document Type: Article
Times cited : (44)

References (24)
  • 1
    • 0002850445 scopus 로고
    • The theory of the bird-cage resonator
    • J. Tropp, The theory of the bird-cage resonator, J. Magn. Reson. 82, 51-62 (1989).
    • (1989) J. Magn. Reson. , vol.82 , pp. 51-62
    • Tropp, J.1
  • 2
    • 0009567930 scopus 로고
    • The theory of an arbitrarily perturbed bird-cage resonator, and a simple method for restoring it to full symmetry
    • J. Tropp, The theory of an arbitrarily perturbed bird-cage resonator, and a simple method for restoring it to full symmetry, J. Magn. Reson. 95, 235-243 (1991).
    • (1991) J. Magn. Reson. , vol.95 , pp. 235-243
    • Tropp, J.1
  • 4
    • 85030063138 scopus 로고    scopus 로고
    • Method of correcting an asymmetry in an NMR radio frequency coil and an improved radio frequency coil having N-fold symmetry and reduced eddy current, U.S. Patent No. 5,196,797 (1993)
    • J. S. Tropp, Method of correcting an asymmetry in an NMR radio frequency coil and an improved radio frequency coil having N-fold symmetry and reduced eddy current, U.S. Patent No. 5,196,797 (1993).
    • Tropp, J.S.1
  • 6
    • 0031884051 scopus 로고    scopus 로고
    • Ultimate intrinsic signal-to-noise ratio in MRI
    • O. Ocali and E. Atalar, Ultimate intrinsic signal-to-noise ratio in MRI, Magn. Reson. Med. 39, 462-473 (1998).
    • (1998) Magn. Reson. Med. , vol.39 , pp. 462-473
    • Ocali, O.1    Atalar, E.2
  • 7
    • 0032374867 scopus 로고    scopus 로고
    • Magnetism in HR NMR probe design. I: General methods
    • F. D. Doty, G. Entzminger, and Y. A. Yang, Magnetism in HR NMR probe design. I: General methods, Concepts Magn. Reson. 10, 133-156 (1998).
    • (1998) Concepts Magn. Reson. , vol.10 , pp. 133-156
    • Doty, F.D.1    Entzminger, G.2    Yang, Y.A.3
  • 9
    • 0030709486 scopus 로고    scopus 로고
    • On the SAR and field inhomogeneity of birdcage coils loaded with the human head
    • J. M. Jin and J. Chen, On the SAR and field inhomogeneity of birdcage coils loaded with the human head, Magn. Reson. Med. 38, 953-963 (1997).
    • (1997) Magn. Reson. Med. , vol.38 , pp. 953-963
    • Jin, J.M.1    Chen, J.2
  • 10
    • 85030070254 scopus 로고    scopus 로고
    • Perturbation method for finding the RFfield on an NMR probe
    • FL
    • L. F. Fuks and W. A. Anderson, Perturbation method for finding the RFfield on an NMR probe, Poster presented at ENC in Orlando, FL (1997).
    • (1997) ENC in Orlando
    • Fuks, L.F.1    Anderson, W.A.2
  • 11
    • 0000504594 scopus 로고
    • An efficient decoupler coil design which reduces heating in conductive samples in superconducting spectrometers
    • D. W. Alderman and D. M. Grant, An efficient decoupler coil design which reduces heating in conductive samples in superconducting spectrometers, J. Magn. Reson. 36, 447-451 (1979).
    • (1979) J. Magn. Reson. , vol.36 , pp. 447-451
    • Alderman, D.W.1    Grant, D.M.2
  • 12
    • 38249021781 scopus 로고
    • A cylindrical-window NMR probe with extended tuning range for studies of the developing heart
    • G. J. Kost, S. E. Anderson, G. B. Matson, and C. B. Conboy, A cylindrical-window NMR probe with extended tuning range for studies of the developing heart, J. Magn. Reson. 82, 238-252 (1989).
    • (1989) J. Magn. Reson. , vol.82 , pp. 238-252
    • Kost, G.J.1    Anderson, S.E.2    Matson, G.B.3    Conboy, C.B.4
  • 16
    • 85030074851 scopus 로고    scopus 로고
    • Low inductance transverse litz foil coils, Patents pending, PCT No. WO 97/26560 (1997)
    • F. D. Doty, Low inductance transverse litz foil coils, Patents pending, PCT No. WO 97/26560 (1997).
    • Doty, F.D.1
  • 17
    • 85030079561 scopus 로고    scopus 로고
    • Center-fed paralleled saddle coils for multinuclear double-resonance NMR or MRI, Patent pending, PCT No. WO 97/33185 (1997)
    • F. D. Doty and G. Entzminger Jr., Center-fed paralleled saddle coils for multinuclear double-resonance NMR or MRI, Patent pending, PCT No. WO 97/33185 (1997).
    • Doty, F.D.1    Entzminger G., Jr.2
  • 18
    • 0007110672 scopus 로고    scopus 로고
    • Probe design and construction
    • Wiley, New York
    • F. D. Doty, Probe design and construction, in "Encyclopedia of NMR," Vol. 6, Wiley, New York (1996).
    • (1996) Encyclopedia of NMR , vol.6
    • Doty, F.D.1
  • 19
    • 85030075817 scopus 로고    scopus 로고
    • formerly Compact Software Inc., Patterson NJ, recently acquired by Ansoft, Pittsburgh, PA
    • ARRL Radio Designer 1.5, formerly Compact Software Inc., Patterson NJ, recently acquired by Ansoft, Pittsburgh, PA.
    • ARRL Radio Designer 1.5
  • 20
    • 85030059314 scopus 로고    scopus 로고
    • Pharmaceutical Sciences, Kyusha Univ., Fukuoka, Japan, private communication
    • Yoko Kanazawa, Pharmaceutical Sciences, Kyusha Univ., Fukuoka, Japan, private communication.
    • Kanazawa, Y.1
  • 21
    • 0030662129 scopus 로고    scopus 로고
    • MR microscopy of perfused brain slices
    • S. J. Blackband, J. D. Bui, D. L. Buckley, T. Zelles, H. D. Plant, B. A. Inglis, and M. I. Phillips, MR microscopy of perfused brain slices, Magn. Reson. Med. 38, 1012-1015; B. Inglis, L. Yang, D. Plant, E. Wirth, and T. Mareci, Diffusion tensor micro-imaging of excised human spinal cord. ISMRM-97, Poster No. 505, Vancouver.
    • Magn. Reson. Med. , vol.38 , pp. 1012-1015
    • Blackband, S.J.1    Bui, J.D.2    Buckley, D.L.3    Zelles, T.4    Plant, H.D.5    Inglis, B.A.6    Phillips, M.I.7
  • 22
    • 0030662129 scopus 로고    scopus 로고
    • Diffusion tensor micro-imaging of excised human spinal cord
    • Poster No. 505, Vancouver
    • S. J. Blackband, J. D. Bui, D. L. Buckley, T. Zelles, H. D. Plant, B. A. Inglis, and M. I. Phillips, MR microscopy of perfused brain slices, Magn. Reson. Med. 38, 1012-1015; B. Inglis, L. Yang, D. Plant, E. Wirth, and T. Mareci, Diffusion tensor micro-imaging of excised human spinal cord. ISMRM-97, Poster No. 505, Vancouver.
    • ISMRM-97
    • Inglis, B.1    Yang, L.2    Plant, D.3    Wirth, E.4    Mareci, T.5
  • 23
    • 0032900145 scopus 로고    scopus 로고
    • A high-temperature superconducting helmholtz probe for microscopy at 9.4 T
    • S. E. Hurlston, W. W. Brey, S. A. Suddarth, and G. A. Johnson, A high-temperature superconducting helmholtz probe for microscopy at 9.4 T, Magn. Reson. Med. 41, 1032-1038 (1999).
    • (1999) Magn. Reson. Med. , vol.41 , pp. 1032-1038
    • Hurlston, S.E.1    Brey, W.W.2    Suddarth, S.A.3    Johnson, G.A.4
  • 24
    • 0031865774 scopus 로고    scopus 로고
    • A spiral volume coil for improved RF field homogeneity at high static magnetic field strength
    • D. C. Alsop, T. J. Connick, G. Mizei, A spiral volume coil for improved RF field homogeneity at high static magnetic field strength, Magn. Reson. Med. 40, 49-54 (1998).
    • (1998) Magn. Reson. Med. , vol.40 , pp. 49-54
    • Alsop, D.C.1    Connick, T.J.2    Mizei, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.