메뉴 건너뛰기




Volumn 84, Issue 3, 1999, Pages 258-263

Value of exercise electrocardiography in the detection of restenosis after coronary angioplasty in patients with one-vessel disease

Author keywords

[No Author keywords available]

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; CLINICAL ARTICLE; CORONARY ARTERY DISEASE; DIAGNOSTIC ACCURACY; DIAGNOSTIC VALUE; EXERCISE ELECTROCARDIOGRAPHY; FEMALE; HUMAN; INTERMETHOD COMPARISON; INTRAVASCULAR ULTRASOUND; MALE; PRIORITY JOURNAL; RESTENOSIS; TRANSLUMINAL CORONARY ANGIOPLASTY; TREADMILL EXERCISE;

EID: 0033180101     PISSN: 00029149     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0002-9149(99)00273-8     Document Type: Article
Times cited : (21)

References (27)
  • 1
    • 0027528915 scopus 로고
    • Early and late exercise testing. Usefulness after percutaneous transluminal coronary angioplasty
    • De la Morena G., Sanchez J.J., Lopez J., Pico F., Ruiperez J.A. Early and late exercise testing. Usefulness after percutaneous transluminal coronary angioplasty. Chest. 103:1993;391-395.
    • (1993) Chest , vol.103 , pp. 391-395
    • De La Morena, G.1    Sanchez, J.J.2    Lopez, J.3    Pico, F.4    Ruiperez, J.A.5
  • 3
    • 0028968791 scopus 로고
    • Limited value of exercise testing in the detection of silent restenosis after successful coronary angioplasty
    • Desmet W., De Scheerder I., Piessens J. Limited value of exercise testing in the detection of silent restenosis after successful coronary angioplasty. Am Heart J. 129:1995;452-459.
    • (1995) Am Heart J , vol.129 , pp. 452-459
    • Desmet, W.1    De Scheerder, I.2    Piessens, J.3
  • 4
    • 0028876102 scopus 로고
    • Our preocupation with coronary luminology. The dissociation between clinical and angiographic findings in ischemic heart disease
    • Topol E.J., Nissen S.E. Our preocupation with coronary luminology. The dissociation between clinical and angiographic findings in ischemic heart disease. Circulation. 92:1995;2333-2342.
    • (1995) Circulation , vol.92 , pp. 2333-2342
    • Topol, E.J.1    Nissen, S.E.2
  • 5
    • 0028910358 scopus 로고
    • An explanation for discrepancy between angiographic and intravascular ultrasound measurements after percutaneous transluminal coronary angioplasty
    • Nakamura S., Mahon D.J., Maheswaran B., Gutfinger D.E., Colombo A., Tobis J.M. An explanation for discrepancy between angiographic and intravascular ultrasound measurements after percutaneous transluminal coronary angioplasty. J Am Coll Cardiol. 25:1995;633-639.
    • (1995) J Am Coll Cardiol , vol.25 , pp. 633-639
    • Nakamura, S.1    Mahon, D.J.2    Maheswaran, B.3    Gutfinger, D.E.4    Colombo, A.5    Tobis, J.M.6
  • 6
    • 0028031238 scopus 로고
    • Intravascular ultrasound imaging in peripheral arterial and coronary artery disease
    • Tardif J.C., Pandian N.G. Intravascular ultrasound imaging in peripheral arterial and coronary artery disease. Curr Opin Cardiol. 9:1994;627-633.
    • (1994) Curr Opin Cardiol , vol.9 , pp. 627-633
    • Tardif, J.C.1    Pandian, N.G.2
  • 10
    • 0024322783 scopus 로고
    • Comparison by quantitative angiographic assessment of coronary stenoses of one view showing the severest narrowing to two orthogonal views
    • Lespérance J., Hudon G., White C.W., Laurier J., Waters D. Comparison by quantitative angiographic assessment of coronary stenoses of one view showing the severest narrowing to two orthogonal views. Am J Cardiol. 64:1989;462-465.
    • (1989) Am J Cardiol , vol.64 , pp. 462-465
    • Lespérance, J.1    Hudon, G.2    White, C.W.3    Laurier, J.4    Waters, D.5
  • 11
    • 0029945505 scopus 로고    scopus 로고
    • Assessing the severity of coronary-artery stenoses
    • Wilson R.F. Assessing the severity of coronary-artery stenoses. N Engl J Med. 334:1996;1735-1737.
    • (1996) N Engl J Med , vol.334 , pp. 1735-1737
    • Wilson, R.F.1
  • 12
    • 0020611318 scopus 로고
    • Study of the vascular reserve of the myocardium with the aid of papaverine
    • Azorin J., Lespérance J., Frija J., Grenier A., Bourassa M.G. Study of the vascular reserve of the myocardium with the aid of papaverine. Ann Chir. 37:1983;143-149.
    • (1983) Ann Chir , vol.37 , pp. 143-149
    • Azorin, J.1    Lespérance, J.2    Frija, J.3    Grenier, A.4    Bourassa, M.G.5
  • 13
    • 0015966216 scopus 로고
    • Physiologic basis for assessing critical coronary stenosis: Instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve
    • Gould K.L., Lipscomb K., Hamilton G.W. Physiologic basis for assessing critical coronary stenosis instantaneous flow response and regional distribution during coronary hyperemia as measures of coronary flow reserve . Am J Cardiol. 33:1974;87-94.
    • (1974) Am J Cardiol , vol.33 , pp. 87-94
    • Gould, K.L.1    Lipscomb, K.2    Hamilton, G.W.3
  • 14
    • 0027272295 scopus 로고
    • Comparison of the Asymptomatic Cardiac Ischemia Pilot and modified Asymptomatic Cardiac Ischemia Pilot versus Bruce and Cornell exercise protocols
    • Tamesis B., Stelken A., Byers S., Shaw L., Younis L., Miller D.D., Chaitman B.R. Comparison of the Asymptomatic Cardiac Ischemia Pilot and modified Asymptomatic Cardiac Ischemia Pilot versus Bruce and Cornell exercise protocols. Am J Cardiol. 72:1993;715-720.
    • (1993) Am J Cardiol , vol.72 , pp. 715-720
    • Tamesis, B.1    Stelken, A.2    Byers, S.3    Shaw, L.4    Younis, L.5    Miller, D.D.6    Chaitman, B.R.7
  • 15
    • 0030968481 scopus 로고    scopus 로고
    • Comparing two diagnostic tests against the same "gold standard" in the same sample
    • Bloch D.A. Comparing two diagnostic tests against the same "gold standard" in the same sample. Biometrics. 53:1997;73-85.
    • (1997) Biometrics , vol.53 , pp. 73-85
    • Bloch, D.A.1
  • 16
    • 0017360308 scopus 로고
    • Variability in the analysis of coronary arteriograms
    • DeRouen T.A., Murray J.A., Owen W. Variability in the analysis of coronary arteriograms. Circulation. 55:1977;324-328.
    • (1977) Circulation , vol.55 , pp. 324-328
    • Derouen, T.A.1    Murray, J.A.2    Owen, W.3
  • 18
    • 0019504885 scopus 로고
    • Accuracy of angiographic determination of left main coronary arterial narrowing
    • Isner J.M., Kishel J., Kent K.M. Accuracy of angiographic determination of left main coronary arterial narrowing. Circulation. 63:1981;1056-1061.
    • (1981) Circulation , vol.63 , pp. 1056-1061
    • Isner, J.M.1    Kishel, J.2    Kent, K.M.3
  • 19
    • 0021321801 scopus 로고
    • Does visual interpretation of the coronary arteriogram predict the physiologic importance of a coronary stenosis?
    • White C.W., Wright C.B., Doty D.B., Hiratza L.F., Eastham C.L., Harrison D.G., Marcus M.L. Does visual interpretation of the coronary arteriogram predict the physiologic importance of a coronary stenosis? N Engl J Med. 310:1984;819-824.
    • (1984) N Engl J Med , vol.310 , pp. 819-824
    • White, C.W.1    Wright, C.B.2    Doty, D.B.3    Hiratza, L.F.4    Eastham, C.L.5    Harrison, D.G.6    Marcus, M.L.7
  • 20
    • 0028182651 scopus 로고
    • Correlation of pharmacologic 99m-Tc-sestamibi myocardial perfusion imaging with poststenotic coronary flow reserve in patients with angiographically intermediate coronary artery stenoses
    • Miller D.D., Donohue T.J., Younis L.T., Bach R.G., Aguirre F.V., Wittry M.D., Goodgold H.M., Chaitman B.R., Kern M.J. Correlation of pharmacologic 99m-Tc-sestamibi myocardial perfusion imaging with poststenotic coronary flow reserve in patients with angiographically intermediate coronary artery stenoses. Circulation. 89:1994;2150-2160.
    • (1994) Circulation , vol.89 , pp. 2150-2160
    • Miller, D.D.1    Donohue, T.J.2    Younis, L.T.3    Bach, R.G.4    Aguirre, F.V.5    Wittry, M.D.6    Goodgold, H.M.7    Chaitman, B.R.8    Kern, M.J.9
  • 21
    • 0026500338 scopus 로고
    • Morphological effects of coronary balloon angioplasty in vivo assessed by intravascular ultrasound imaging
    • Honye J., Mahon D.J., Jain A., White C.J., Ramee S.R., Wallis J.B., Al-Zarka A., Tobis J.M. Morphological effects of coronary balloon angioplasty in vivo assessed by intravascular ultrasound imaging. Circulation. 85:1992;1012-1025.
    • (1992) Circulation , vol.85 , pp. 1012-1025
    • Honye, J.1    Mahon, D.J.2    Jain, A.3    White, C.J.4    Ramee, S.R.5    Wallis, J.B.6    Al-Zarka, A.7    Tobis, J.M.8
  • 23
    • 0031035934 scopus 로고    scopus 로고
    • Diagnostic value of exercise electrocardiography and angina after coronary artery stenting
    • Legrand V., Raskinet B., Laarman G., Danchin N., Morel M.A., Serruys P.W. Diagnostic value of exercise electrocardiography and angina after coronary artery stenting. Am Heart J. 133:1997;240-248.
    • (1997) Am Heart J , vol.133 , pp. 240-248
    • Legrand, V.1    Raskinet, B.2    Laarman, G.3    Danchin, N.4    Morel, M.A.5    Serruys, P.W.6
  • 24
    • 0024916086 scopus 로고
    • Detection of restenosis after coronary angioplasty for single vessel disease: How reliable are exercise electrocardiography and scintigraphy in asymptomatic patients?
    • Schroeder E., Marchandise B., De Coster P., Brichant C., Mitri K., Pieters D., Kremer R. Detection of restenosis after coronary angioplasty for single vessel disease how reliable are exercise electrocardiography and scintigraphy in asymptomatic patients? Eur Heart J. 10:(suppl G):1989;18-21.
    • (1989) Eur Heart J , vol.10 , Issue.SUPPL. G , pp. 18-21
    • Schroeder, E.1    Marchandise, B.2    De Coster, P.3    Brichant, C.4    Mitri, K.5    Pieters, D.6    Kremer, R.7
  • 25
    • 0025179225 scopus 로고
    • Assessment of silent restenosis and long term follow-up after successful angioplasty in single vessel coronary artery disease: The value of quantitative exercise electrocardiography and quantitative coronary angiography
    • Laarman G., Luijten H.F., Van Zeyl L.G.P.M., Beatt K.J., Tijssen J.G.P., Serruys P.W., De Feyter P.J. Assessment of silent restenosis and long term follow-up after successful angioplasty in single vessel coronary artery disease the value of quantitative exercise electrocardiography and quantitative coronary angiography . J Am Coll Cardiol. 16:1990;578-585.
    • (1990) J Am Coll Cardiol , vol.16 , pp. 578-585
    • Laarman, G.1    Luijten, H.F.2    Van Zeyl, L.G.P.M.3    Beatt, K.J.4    Tijssen, J.G.P.5    Serruys, P.W.6    De Feyter, P.J.7
  • 26
    • 0025098733 scopus 로고
    • Very early prediction of restenosis after successful coronary angioplasty: Anatomic and functional assessment
    • El-Tamimi H., Davies G.J., Hackett, Fragasso G., Crea F., Maseri A. Very early prediction of restenosis after successful coronary angioplasty anatomic and functional assessment . J Am Coll Cardiol. 15:1990;259-264.
    • (1990) J Am Coll Cardiol , vol.15 , pp. 259-264
    • El-Tamimi, H.1    Davies, G.J.2    Hackett3    Fragasso, G.4    Crea, F.5    Maseri, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.