메뉴 건너뛰기




Volumn 55, Issue 5-6, 1999, Pages 673-676

Intelligent feedback release systems and the application to neuron network model research

Author keywords

Controlled release; Intelligent system; Ion beam; Neuron network model; Polycarbonate film; Signal responsiveness; Silicon wafer; Stimuli sensitive hydrogel

Indexed keywords

CONTROLLED DRUG DELIVERY; ENZYME IMMOBILIZATION; HYDROGELS; ION BEAMS; NEURAL NETWORKS; SILICON WAFERS;

EID: 0033179538     PISSN: 0969806X     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0969-806X(99)00209-1     Document Type: Conference Paper
Times cited : (9)

References (7)
  • 1
    • 0345362365 scopus 로고
    • Progress in polymer processing
    • A. Singh, & J. Silverman. New York: Hansen
    • Kaetsu I. Progress in polymer processing. Singh A., Silverman J. Radiation processing of polymers. 1992;Hansen, New York.
    • (1992) Radiation Processing of Polymers
    • Kaetsu, I.1
  • 2
    • 0026908674 scopus 로고
    • Synthesis of electro-responsive hydrogels by radiation polymerization of sodium acrylate
    • Kaetsu I., Uchida K., Morita Y., Okubo M. Synthesis of electro-responsive hydrogels by radiation polymerization of sodium acrylate. Rad. Phys. Chem. 40:1992;157.
    • (1992) Rad. Phys. Chem , vol.40 , pp. 157
    • Kaetsu, I.1    Uchida, K.2    Morita, Y.3    Okubo, M.4
  • 3
    • 12044255341 scopus 로고
    • Radiation synthesis of polymeric materials for biomedical and biochemical applications
    • Kaetsu I. Radiation synthesis of polymeric materials for biomedical and biochemical applications. Advanced Polymer Science. 105:1993;81.
    • (1993) Advanced Polymer Science , vol.105 , pp. 81
    • Kaetsu, I.1
  • 4
    • 0029011252 scopus 로고
    • Signal responsive chemical delivery systems by radiation techniques and the use for brain research
    • Kaetsu I. Signal responsive chemical delivery systems by radiation techniques and the use for brain research. Radiat. Phys. Chem. 46:1995;247.
    • (1995) Radiat. Phys. Chem , vol.46 , pp. 247
    • Kaetsu, I.1
  • 5
    • 0029156774 scopus 로고
    • Signal responsive drug delivery system-pH change responsive release of neurotransmitter in micro pore membrane and micro pore semiconductor chip
    • Kaetsu, I., Uchida, K., Sutani, K., Ueda, S., Shindo, H., Doi, K., 1995. Signal responsive drug delivery system-pH change responsive release of neurotransmitter in micro pore membrane and micro pore semiconductor chip. In: Proc. Int. Symp. Control. Rel. Bioact. Mater, 22, p. 754.
    • (1995) In: Proc. Int. Symp. Control. Rel. Bioact. Mater , vol.22 , pp. 754
    • Kaetsu, I.1    Uchida, K.2    Sutani, K.3    Ueda, S.4    Shindo, H.5    Doi, K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.