메뉴 건너뛰기




Volumn 17, Issue 6, 1999, Pages 486-492

Influence of the collateral function of the circle of Willis on hemispherical perfusion during carotid occlusion as assessed by transcranial colour-coded duplex ultrasonography

Author keywords

Carotid artery; Cerebrovascular circulation; Circle of Willis; Doppler; Transcranial; Ultrasonography

Indexed keywords

ADULT; AGED; ARTICLE; ATHEROSCLEROSIS; BASILAR ARTERY; BLOOD FLOW VELOCITY; BRAIN CIRCULUS ARTERIOSUS; BRAIN PERFUSION; CAROTID ARTERY OBSTRUCTION; COLOR ULTRASOUND FLOWMETRY; FEMALE; HEMISPHERE; HUMAN; MAJOR CLINICAL STUDY; MALE; MIDDLE CEREBRAL ARTERY; PRIORITY JOURNAL;

EID: 0033152715     PISSN: 10785884     EISSN: None     Source Type: Journal    
DOI: 10.1053/ejvs.1999.0824     Document Type: Article
Times cited : (28)

References (28)
  • 2
    • 0028198859 scopus 로고
    • The anatomy of the posterior communicating artery as a risk factor for ischemic cerebral infarction
    • 2 SHOMER DF, MARKS MP, STEINBERG GK et al. The anatomy of the posterior communicating artery as a risk factor for ischemic cerebral infarction. N Engl J Med 1994; 330: 1565-1570.
    • (1994) N Engl J Med , vol.330 , pp. 1565-1570
    • Shomer, D.F.1    Marks, M.P.2    Steinberg, G.K.3
  • 3
    • 0028107537 scopus 로고
    • Cerebral vasomotor reactivity is significantly reduced in low-flow as compared to thromboembolic infarctions: The key role of the circle of Willis
    • 3 RINGELSTEIN EB, WEILLER C, WECKESSER M, WECKESSER S. Cerebral vasomotor reactivity is significantly reduced in low-flow as compared to thromboembolic infarctions: the key role of the circle of Willis. J Neurol Sci 1994; 121: 103-109.
    • (1994) J Neurol Sci , vol.121 , pp. 103-109
    • Ringelstein, E.B.1    Weiller, C.2    Weckesser, M.3    Weckesser, S.4
  • 4
    • 0029050881 scopus 로고
    • Effect of collateral flow patterns on outcome of carotid occlusion
    • 4 HEDERA P, BUJDAKOVA J, TRAUBNER P. Effect of collateral flow patterns on outcome of carotid occlusion. Eur Neurol 1995; 35: 212-216.
    • (1995) Eur Neurol , vol.35 , pp. 212-216
    • Hedera, P.1    Bujdakova, J.2    Traubner, P.3
  • 5
    • 70449253131 scopus 로고
    • Anatomical studies of the circle of Willis in normal brain
    • 5 ALPERS BJ, BERRY RG, PADDISON RM. Anatomical studies of the circle of Willis in normal brain. Arch Neurol Psych 1959; 81: 409-418.
    • (1959) Arch Neurol Psych , vol.81 , pp. 409-418
    • Alpers, B.J.1    Berry, R.G.2    Paddison, R.M.3
  • 6
    • 73649191389 scopus 로고
    • Variation in form of circle of Willis: The relation of the variations to collateral circulation: Anatomic analysis
    • 6 RIGGS HE, RUPP C. Variation in form of circle of Willis: the relation of the variations to collateral circulation: anatomic analysis. Arch Neurol 1963; 8: 8-14.
    • (1963) Arch Neurol , vol.8 , pp. 8-14
    • Riggs, H.E.1    Rupp, C.2
  • 7
    • 0014179732 scopus 로고
    • The circle of Willis - The incidence of developmental abnormalities in normal and infarcted brains
    • 7 BATTACHARJI SK, HUTCHINSON EC, MCCALL AJ. The circle of Willis - the incidence of developmental abnormalities in normal and infarcted brains. Brain 1967; 90: 747-758.
    • (1967) Brain , vol.90 , pp. 747-758
    • Battacharji, S.K.1    Hutchinson, E.C.2    McCall, A.J.3
  • 8
    • 0025676213 scopus 로고
    • Transcranial color-coded real-time sonography in adults
    • 8 BOGDAHN U, BECKER G, WINKLER J et al. Transcranial color-coded real-time sonography in adults. Stroke 1990; 21: 1680-1688.
    • (1990) Stroke , vol.21 , pp. 1680-1688
    • Bogdahn, U.1    Becker, G.2    Winkler, J.3
  • 9
    • 0029094348 scopus 로고
    • Assessment of intracranial primary collaterals using transcranial color-coded real-time sonography
    • 9 MARTIN PJ, SMITH JL, GAUNT ME, NAYLOR AR. Assessment of intracranial primary collaterals using transcranial color-coded real-time sonography. J Neuroimag 1995; 5: 199-205.
    • (1995) J Neuroimag , vol.5 , pp. 199-205
    • Martin, P.J.1    Smith, J.L.2    Gaunt, M.E.3    Naylor, A.R.4
  • 10
    • 0031015618 scopus 로고    scopus 로고
    • Transcranial color-coded duplex sonography in the evaluation of collateral flow through the circle of Willis
    • 10 BAUMGARTNER RW, BAUMGARTNER I, MATTLE HP, SCHROTH G. Transcranial color-coded duplex sonography in the evaluation of collateral flow through the circle of Willis. Am J Neuroradiol 1997; 18: 127-133.
    • (1997) Am J Neuroradiol , vol.18 , pp. 127-133
    • Baumgartner, R.W.1    Baumgartner, I.2    Mattle, H.P.3    Schroth, G.4
  • 11
    • 0020394689 scopus 로고
    • Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries
    • 11 AASLID R, MARKWALDER T, NORNES H. Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries. J Neurosurg 1982; 57: 769-774.
    • (1982) J Neurosurg , vol.57 , pp. 769-774
    • Aaslid, R.1    Markwalder, T.2    Nornes, H.3
  • 13
    • 0025034664 scopus 로고
    • Collateral development after carotid artery occlusion in Fischer 344 rats
    • 13 COYLE P, PANZENBECK MJ. Collateral development after carotid artery occlusion in Fischer 344 rats. Stroke 1990; 21: 316-321.
    • (1990) Stroke , vol.21 , pp. 316-321
    • Coyle, P.1    Panzenbeck, M.J.2
  • 14
    • 0029117405 scopus 로고
    • Patients with low stump pressure and possible pressure fall in the middle cerebral artery during carotid surgery may be identified preoperatively by transcranial Doppler
    • 14 KJÄLLMAN L, BLOMSTRAND C, HOLM J, LUNDH T, VOLKMANN R. Patients with low stump pressure and possible pressure fall in the middle cerebral artery during carotid surgery may be identified preoperatively by transcranial Doppler. Eur Neurol 1995; 35: 259-263.
    • (1995) Eur Neurol , vol.35 , pp. 259-263
    • Kjällman, L.1    Blomstrand, C.2    Holm, J.3    Lundh, T.4    Volkmann, R.5
  • 15
    • 0028866804 scopus 로고
    • The role of the circle of Willis in carotid occlusion: Assessment with phase contrast MR angiography and transcranial duplex
    • 15 MIRALLES M, DOLZ JL, COTILLAS J et al. The role of the circle of Willis in carotid occlusion: assessment with phase contrast MR angiography and transcranial duplex. Eur J Endovasc Surg 1995; 10: 424-430.
    • (1995) Eur J Endovasc Surg , vol.10 , pp. 424-430
    • Miralles, M.1    Dolz, J.L.2    Cotillas, J.3
  • 16
    • 0028889263 scopus 로고
    • Effects of anterior communicating artery diameter on cerebral hemodynamics in internal carotid artery disease
    • 16 CASSOT F, VERGEUR V, BOSSUET P et al. Effects of anterior communicating artery diameter on cerebral hemodynamics in internal carotid artery disease. Circulation 1995; 92: 3122-3131.
    • (1995) Circulation , vol.92 , pp. 3122-3131
    • Cassot, F.1    Vergeur, V.2    Bossuet, P.3
  • 17
    • 0022375995 scopus 로고
    • Assessment of intracranial hemodynamics in carotid artery disease by transcranial Doppler ultrasound
    • 17 LINDEGAARD K, SØREN JB, GROLIMUND P et al. Assessment of intracranial hemodynamics in carotid artery disease by transcranial Doppler ultrasound. J Neurosurg 1985; 63: 890-898.
    • (1985) J Neurosurg , vol.63 , pp. 890-898
    • Lindegaard, K.1    Søren, J.B.2    Grolimund, P.3
  • 18
    • 0028878788 scopus 로고
    • Transcranial Doppler ultrasound in the evaluation of collateral blood flow in patients with internal carotid artery occlusion: Correlation with cerebral angiography
    • 18 MÜLLER M, HERMES M, BRÜCKMANN H, SCHIMRIGK K. Transcranial Doppler ultrasound in the evaluation of collateral blood flow in patients with internal carotid artery occlusion: correlation with cerebral angiography. Am J Neuroradiol 1995; 16: 195-202.
    • (1995) Am J Neuroradiol , vol.16 , pp. 195-202
    • Müller, M.1    Hermes, M.2    Brückmann, H.3    Schimrigk, K.4
  • 19
    • 0026739296 scopus 로고
    • Non-invasive assessment of the circle of Willis using transcranial pulsed Doppler ultrasound with angiographic correlation
    • 19 CHAUDHURI R, PADAYACHEE TS, LEWIS RR, GOSLING RG, Cox TCS. Non-invasive assessment of the circle of Willis using transcranial pulsed Doppler ultrasound with angiographic correlation. Clin Radiol 1992; 46: 193-197.
    • (1992) Clin Radiol , vol.46 , pp. 193-197
    • Chaudhuri, R.1    Padayachee, T.S.2    Lewis, R.R.3    Gosling, R.G.4    Cox, T.C.S.5
  • 20
    • 0025668760 scopus 로고
    • Comparison of transcranial and cervical continuous-wave Doppler in the evaluation of intracranial collateral circulation
    • 20 BASS A, KRUPSKI WC, DILLEY RB, BERNSTEIN EF, OTIS SM. Comparison of transcranial and cervical continuous-wave Doppler in the evaluation of intracranial collateral circulation. Stroke 1990; 21: 1584-1588.
    • (1990) Stroke , vol.21 , pp. 1584-1588
    • Bass, A.1    Krupski, W.C.2    Dilley, R.B.3    Bernstein, E.F.4    Otis, S.M.5
  • 21
    • 0023807724 scopus 로고
    • Importance of cerebral collateral pathways during carotid endarterectomy
    • 21 SCHNEIDER PA, RINGELSTEIN EB, ROSSMAN ME et al. Importance of cerebral collateral pathways during carotid endarterectomy. Stroke 1988; 19: 1328-1334.
    • (1988) Stroke , vol.19 , pp. 1328-1334
    • Schneider, P.A.1    Ringelstein, E.B.2    Rossman, M.E.3
  • 22
    • 0002420341 scopus 로고
    • Anatomy and freehand examination techniques
    • Newell DW, Aaslid R, eds. New York: Ravenpress
    • 22 FUJIOKA KA, DOUVILLE CM. Anatomy and freehand examination techniques. In: Newell DW, Aaslid R, eds. Transcranial Doppler. New York: Ravenpress, 1992: 9-31.
    • (1992) Transcranial Doppler , pp. 9-31
    • Fujioka, K.A.1    Douville, C.M.2
  • 23
    • 0016680104 scopus 로고
    • The competence of the circle of Willis in extracranial cerebrovascular atherosclerosis
    • 23 COOKE PA, GEE W, WYLIE EJ. The competence of the circle of Willis in extracranial cerebrovascular atherosclerosis. South Afr J Surg 1975; 13: 7-14.
    • (1975) South Afr J Surg , vol.13 , pp. 7-14
    • Cooke, P.A.1    Gee, W.2    Wylie, E.J.3
  • 24
    • 0024546198 scopus 로고
    • Validity of cerebral arterial blood flow calculations from velocity measurements
    • 24 KONTOS HA. Validity of cerebral arterial blood flow calculations from velocity measurements. Stroke 1989; 20: 1-3.
    • (1989) Stroke , vol.20 , pp. 1-3
    • Kontos, H.A.1
  • 25
    • 0026543567 scopus 로고
    • A comparison of transcranial doppler and cerebral blood flow studies to assess cerebral vasoreactivity
    • 25 DAHL A, LINDEGAARD KF, RUSSELL D et al. A comparison of transcranial Doppler and cerebral blood flow studies to assess cerebral vasoreactivity. Stroke 1992; 23: 15-19.
    • (1992) Stroke , vol.23 , pp. 15-19
    • Dahl, A.1    Lindegaard, K.F.2    Russell, D.3
  • 27
    • 0025181173 scopus 로고
    • A simple test to assess cerebrovascular reserve capacity using transcranial Doppler sonography and acetazolamide
    • 27 PIEPGRAS A, SCHMIEDEK P, LEINSINGER G et al. A simple test to assess cerebrovascular reserve capacity using transcranial Doppler sonography and acetazolamide. Stroke 1990; 21: 1306-1311.
    • (1990) Stroke , vol.21 , pp. 1306-1311
    • Piepgras, A.1    Schmiedek, P.2    Leinsinger, G.3
  • 28
    • 0344577486 scopus 로고    scopus 로고
    • Relationships between cerebral regional blood flow velocities and volumetric blood flows and their respective reactivities to acetazolamide
    • 28 DÉMOLIS P, TRAN DINH YR, GIUDICELLI JF. Relationships between cerebral regional blood flow velocities and volumetric blood flows and their respective reactivities to acetazolamide. Stroke 1996; 27: 1835-1839.
    • (1996) Stroke , vol.27 , pp. 1835-1839
    • Démolis, P.1    Tran Dinh, Y.R.2    Giudicelli, J.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.