메뉴 건너뛰기




Volumn 99, Issue 21, 1999, Pages 2742-2749

Multicenter clinical trial to evaluate the efficacy of correction for photon attenuation and scatter in SPECT myocardial perfusion imaging

Author keywords

Diagnosis; Imaging; Nuclear medicine; Perfusion; Radioisotopes

Indexed keywords

METHOXY ISOBUTYL ISONITRILE TECHNETIUM TC 99M; RADIOISOTOPE;

EID: 0033152366     PISSN: 00097322     EISSN: None     Source Type: Journal    
DOI: 10.1161/01.CIR.99.21.2742     Document Type: Article
Times cited : (213)

References (35)
  • 1
    • 0028212829 scopus 로고
    • How to detect and avoid myocardial perfusion SPECT artifacts
    • DePuey EG. How to detect and avoid myocardial perfusion SPECT artifacts. J Nucl Med. 1994;35:699-702.
    • (1994) J Nucl Med. , vol.35 , pp. 699-702
    • DePuey, E.G.1
  • 2
    • 0024573667 scopus 로고
    • Optimal specificity of thallium-201 SPECT through recognition of imaging artifacts
    • DePuey EG, Garcia EV. Optimal specificity of thallium-201 SPECT through recognition of imaging artifacts. J Nucl Med. 1989;30:441-449.
    • (1989) J Nucl Med. , vol.30 , pp. 441-449
    • DePuey, E.G.1    Garcia, E.V.2
  • 3
    • 0029069659 scopus 로고
    • Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact
    • DePuey EG, Rozanski A. Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact. J Nucl Med. 1995;36:952-955.
    • (1995) J Nucl Med. , vol.36 , pp. 952-955
    • DePuey, E.G.1    Rozanski, A.2
  • 4
    • 0017452940 scopus 로고
    • A method for attenuation correction in radionuclide computed tomography
    • Chang LT. A method for attenuation correction in radionuclide computed tomography. IEEE Trans Nucl Sci. 1978;25:638-643.
    • (1978) IEEE Trans Nucl Sci. , vol.25 , pp. 638-643
    • Chang, L.T.1
  • 5
    • 0030022458 scopus 로고    scopus 로고
    • Simultaneous transmission/emission myocardial perfusion tomography: Diagnostic accuracy of attenuation corrected Tc-99m sestamibi single-photon emission computed tomography
    • Ficaro EA, Fessler JA, Shreve PD, Kritzman JN, Rose PA, Corbett JR. Simultaneous transmission/emission myocardial perfusion tomography: diagnostic accuracy of attenuation corrected Tc-99m sestamibi single-photon emission computed tomography. Circulation, 1996;93:463-473.
    • (1996) Circulation , vol.93 , pp. 463-473
    • Ficaro, E.A.1    Fessler, J.A.2    Shreve, P.D.3    Kritzman, J.N.4    Rose, P.A.5    Corbett, J.R.6
  • 6
    • 0029017223 scopus 로고
    • Simultaneous transmission-emission thallium-201 cardiac SPECT: Effect of attenuation correction on myocardial tracer distribution
    • Ficaro EA, Fessler JA, Acklermann R, Rogers M, Corbett JR, Schwaiger M. Simultaneous transmission-emission thallium-201 cardiac SPECT: effect of attenuation correction on myocardial tracer distribution. J Nucl Med. 1995;36:921-931.
    • (1995) J Nucl Med. , vol.36 , pp. 921-931
    • Ficaro, E.A.1    Fessler, J.A.2    Acklermann, R.3    Rogers, M.4    Corbett, J.R.5    Schwaiger, M.6
  • 7
    • 0023243756 scopus 로고
    • Improved SPECT using simultaneous emission and transmission tomography
    • Bailey DL, Hutton BF, Walker PJ. Improved SPECT using simultaneous emission and transmission tomography. J Nucl Med. 1987;28:844-851.
    • (1987) J Nucl Med. , vol.28 , pp. 844-851
    • Bailey, D.L.1    Hutton, B.F.2    Walker, P.J.3
  • 8
    • 0024549419 scopus 로고
    • A technique for using CT images in attenuation correction and quantification in SPECT
    • Fleming JS. A technique for using CT images in attenuation correction and quantification in SPECT. Nucl Med Commun. 1989;10:83-97.
    • (1989) Nucl Med Commun. , vol.10 , pp. 83-97
    • Fleming, J.S.1
  • 9
    • 0026469847 scopus 로고
    • SPECT quantitation: A simplified method of attenuation and scatter correction for cardiac imaging
    • Galt JR, Cullom SJ, Garcia EV. SPECT quantitation: a simplified method of attenuation and scatter correction for cardiac imaging. J Nucl Med. 1992;33:2232-2237.
    • (1992) J Nucl Med. , vol.33 , pp. 2232-2237
    • Galt, J.R.1    Cullom, S.J.2    Garcia, E.V.3
  • 10
    • 0027665228 scopus 로고
    • Fast transmission CT for determining attenuation maps using a collimated line source, rotatable air-copper-lead attenuators and fan-beam collimation
    • Jaszczak RJ, Gilland DR, Hanson MW, Jang S, Geer KL, Coleman RE. Fast transmission CT for determining attenuation maps using a collimated line source, rotatable air-copper-lead attenuators and fan-beam collimation. J Nucl Med. 1993;34:1577-1586.
    • (1993) J Nucl Med. , vol.34 , pp. 1577-1586
    • Jaszczak, R.J.1    Gilland, D.R.2    Hanson, M.W.3    Jang, S.4    Geer, K.L.5    Coleman, R.E.6
  • 11
    • 0029564459 scopus 로고
    • Attenuation compensation for cardiac single-photon emission computed tomographic imaging, I: Impact of attenuation and methods of estimating attenuation maps
    • King MA, Tsui BMW, Pan TS. Attenuation compensation for cardiac single-photon emission computed tomographic imaging, I: impact of attenuation and methods of estimating attenuation maps. J Nucl Cardiol 1995;2:513-524.
    • (1995) J Nucl Cardiol , vol.2 , pp. 513-524
    • King, M.A.1    Tsui, B.M.W.2    Pan, T.S.3
  • 12
    • 0030070816 scopus 로고    scopus 로고
    • Attenuation compensation for cardiac single-photon emission computed tomographic imaging, II: Attenuation compensation algorithms
    • King MA, Tsui BMW, Pan TS, Glick SJ, Soares EJ. Attenuation compensation for cardiac single-photon emission computed tomographic imaging, II: attenuation compensation algorithms. J Nucl Cardiol. 1996; 3:55-63.
    • (1996) J Nucl Cardiol. , vol.3 , pp. 55-63
    • King, M.A.1    Tsui, B.M.W.2    Pan, T.S.3    Glick, S.J.4    Soares, E.J.5
  • 14
    • 0027429814 scopus 로고
    • A scanning line source for simultaneous emission and transmission measurements in SPECT
    • Tan P, Bailey D, Meikl SR, Eberl S, Fulton R, Hutton B. A scanning line source for simultaneous emission and transmission measurements in SPECT. J Nucl Med. 1993;34:1752-1760.
    • (1993) J Nucl Med. , vol.34 , pp. 1752-1760
    • Tan, P.1    Bailey, D.2    Meikl, S.R.3    Eberl, S.4    Fulton, R.5    Hutton, B.6
  • 17
    • 0018750969 scopus 로고
    • Analysis of probability as an aid in the clinical diagnosis of coronary artery disease
    • Diamond GA, Forrester JS. Analysis of probability as an aid in the clinical diagnosis of coronary artery disease. N Engl J Med. 1979;300: 1350-1358.
    • (1979) N Engl J Med. , vol.300 , pp. 1350-1358
    • Diamond, G.A.1    Forrester, J.S.2
  • 18
    • 0005714942 scopus 로고    scopus 로고
    • Compensation of attenuation map errors from Tc-99m-sestamibi downscatter with simultaneous Gd-153 transmission scanning
    • Abstract
    • Cullom SJ, Liu L, White ML. Compensation of attenuation map errors from Tc-99m-sestamibi downscatter with simultaneous Gd-153 transmission scanning. J Nucl Med. 1996;37:215P. Abstract.
    • (1996) J Nucl Med. , vol.37
    • Cullom, S.J.1    Liu, L.2    White, M.L.3
  • 19
    • 0003244347 scopus 로고    scopus 로고
    • A modified Weiner filter method for nonstationary resolution recovery with scatter and iterative attenuation correction for cardiac SPECT
    • Abstract
    • Liu L, Cullom SJ, White ML. A modified Weiner filter method for nonstationary resolution recovery with scatter and iterative attenuation correction for cardiac SPECT. J Nucl Med. 1996;37:210P. Abstract.
    • (1996) J Nucl Med. , vol.37
    • Liu, L.1    Cullom, S.J.2    White, M.L.3
  • 20
    • 0029111972 scopus 로고
    • Incremental value of prognostic testing in patients with known or suspected ischemic heart disease: A basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon computed tomography
    • Berman DS, Hachamovitch R, Kiat H, Cohen I, Cabico A, Wang FP, Friedman JD, Germano G, Van Train K, Diamond GA. Incremental value of prognostic testing in patients with known or suspected ischemic heart disease: a basis for optimal utilization of exercise technetium-99m sestamibi myocardial perfusion single-photon computed tomography. J Am Coll Cardiol. 1995;26:639-647.
    • (1995) J Am Coll Cardiol. , vol.26 , pp. 639-647
    • Berman, D.S.1    Hachamovitch, R.2    Kiat, H.3    Cohen, I.4    Cabico, A.5    Wang, F.P.6    Friedman, J.D.7    Germano, G.8    Van Train, K.9    Diamond, G.A.10
  • 21
    • 0025293511 scopus 로고
    • Quantitative analysis of tomographic stress thallium-201 myocardial scintigrams: A multicenter trial
    • Van Train KF, Maddahi J, Berman DS, Kiat H, Areeda J, Prigent F, Friedman J. Quantitative analysis of tomographic stress thallium-201 myocardial scintigrams: a multicenter trial. J Nucl Med. 1990;31: 1168-1179.
    • (1990) J Nucl Med. , vol.31 , pp. 1168-1179
    • Van Train, K.F.1    Maddahi, J.2    Berman, D.S.3    Kiat, H.4    Areeda, J.5    Prigent, F.6    Friedman, J.7
  • 22
    • 0018079655 scopus 로고
    • Basic principles of ROC analysis
    • Metz CE. Basic principles of ROC analysis. Semin Nucl Med. 1978;8: 283-298.
    • (1978) Semin Nucl Med. , vol.8 , pp. 283-298
    • Metz, C.E.1
  • 23
    • 0022470978 scopus 로고
    • ROC methodology in radiologic imaging
    • Metz CE. ROC methodology in radiologic imaging. Invest Radiol. 1986; 21:720-733.
    • (1986) Invest Radiol. , vol.21 , pp. 720-733
    • Metz, C.E.1
  • 24
    • 0002167042 scopus 로고
    • A new approach for testing the significance of differences between ROC curves measured from correlated data
    • Decanick F, ed. The Hague: Martinus Lijhof
    • Metz CE, Wang P-L, Kronman HB. A new approach for testing the significance of differences between ROC curves measured from correlated data. In: Decanick F, ed. Information Processing in Medical Imaging VIII. The Hague: Martinus Lijhof; 1984:432-445.
    • (1984) Information Processing in Medical Imaging VIII , pp. 432-445
    • Metz, C.E.1    Wang, P.-L.2    Kronman, H.B.3
  • 25
    • 0027504581 scopus 로고
    • Separate rest thallium-201/stress technetium-99m sestamibi dual isotope myocardial perfusion single photon emission computed tomograph: A clinical validation study
    • Berman DS, Kiat H, Friedman JD, Wang FP, Van Train K, Matzer L, Maddahi J, Germano G. Separate rest thallium-201/stress technetium-99m sestamibi dual isotope myocardial perfusion single photon emission computed tomograph: a clinical validation study. J Am Coll Cardiol. 1993;22:1455-1464.
    • (1993) J Am Coll Cardiol. , vol.22 , pp. 1455-1464
    • Berman, D.S.1    Kiat, H.2    Friedman, J.D.3    Wang, F.P.4    Van Train, K.5    Matzer, L.6    Maddahi, J.7    Germano, G.8
  • 26
    • 0027406232 scopus 로고
    • Do false positive thallium-201 scans lead to unnecessary catheterization? Outcome of patients with perfusion defects on quantitative planar thallium scintigraphy
    • Desmarais R, Kaul S, Watson D, Beller G. Do false positive thallium-201 scans lead to unnecessary catheterization? Outcome of patients with perfusion defects on quantitative planar thallium scintigraphy. J Am Coll Cardiol. 1993;21:1058-1063.
    • (1993) J Am Coll Cardiol. , vol.21 , pp. 1058-1063
    • Desmarais, R.1    Kaul, S.2    Watson, D.3    Beller, G.4
  • 27
    • 0003115566 scopus 로고    scopus 로고
    • The prevalence of non-uniform soft tissue attenuation in myocardial SPECT perfusion imaging and the impact of gated SPECT
    • Abstract
    • Holly TA, Parker MA, Hendel RC. The prevalence of non-uniform soft tissue attenuation in myocardial SPECT perfusion imaging and the impact of gated SPECT. J Nucl Cardiol. 1997;4:S103. Abstract.
    • (1997) J Nucl Cardiol. , vol.4
    • Holly, T.A.1    Parker, M.A.2    Hendel, R.C.3
  • 28
    • 0031032541 scopus 로고    scopus 로고
    • Comparative diagnostic accuracy of Tl-201 and Tc-99m sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women
    • Taillefer R, DePuey E, Udelson J, Beller G, Latour Y, Reeves F. Comparative diagnostic accuracy of Tl-201 and Tc-99m sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women. J Am Coll Cardiol. 1997;29:69-77.
    • (1997) J Am Coll Cardiol. , vol.29 , pp. 69-77
    • Taillefer, R.1    DePuey, E.2    Udelson, J.3    Beller, G.4    Latour, Y.5    Reeves, F.6
  • 29
    • 0024549209 scopus 로고
    • Prone decubitus: A solution to inferior wall attenuation in thallium-201 myocardial tomography
    • Esquerre J-P, Coca FJ, Martinez SJ, Guiraud RF. Prone decubitus: a solution to inferior wall attenuation in thallium-201 myocardial tomography. J Nucl Med. 1989;30:398-401.
    • (1989) J Nucl Med. , vol.30 , pp. 398-401
    • Esquerre, J.-P.1    Coca, F.J.2    Martinez, S.J.3    Guiraud, R.F.4
  • 30
    • 0028258216 scopus 로고
    • The role of clinical data in interpretation of perfusion images
    • Simons M, Parker JA, Udelson JE, Gervino EV. The role of clinical data in interpretation of perfusion images. J Nucl Med. 1994;35:740-741.
    • (1994) J Nucl Med. , vol.35 , pp. 740-741
    • Simons, M.1    Parker, J.A.2    Udelson, J.E.3    Gervino, E.V.4
  • 32
    • 0030866755 scopus 로고    scopus 로고
    • Attenuation correction by simultaneous emission-transmission single-photon emission tomography using a technetium-99m labeled radiotracer: Impact on diagnostic accuracy
    • Kluge R, Satter B, Seese A, Knapp WH. Attenuation correction by simultaneous emission-transmission single-photon emission tomography using a technetium-99m labeled radiotracer: impact on diagnostic accuracy. Eur J Nucl Med. 1997;24:1107-1114.
    • (1997) Eur J Nucl Med. , vol.24 , pp. 1107-1114
    • Kluge, R.1    Satter, B.2    Seese, A.3    Knapp, W.H.4
  • 33
    • 0030027469 scopus 로고    scopus 로고
    • A Monte Carlo investigation of artifacts caused by liver uptake in single photon emission computed tomography perfusion imaging with Tc-99m-labeled agents
    • King MA, Xia W, DeVries DJ, Pan TS, Villegas BJ, Dahlberg S, Tsui BMW, Ljungberg MH, Morgan HT. A Monte Carlo investigation of artifacts caused by liver uptake in single photon emission computed tomography perfusion imaging with Tc-99m-labeled agents. J Nucl Cardiol. 1996;3:18-29.
    • (1996) J Nucl Cardiol. , vol.3 , pp. 18-29
    • King, M.A.1    Xia, W.2    DeVries, D.J.3    Pan, T.S.4    Villegas, B.J.5    Dahlberg, S.6    Tsui, B.M.W.7    Ljungberg, M.H.8    Morgan, H.T.9
  • 34
    • 85038166077 scopus 로고
    • Limitation of simultaneous transmission emission SPECT correction of non-uniform attenuation: A phantom study
    • Abstract
    • Eror EL, DeMan P, Liu Y-H, Heller EN, Sinusas AJ, Wackers FJT. Limitation of simultaneous transmission emission SPECT correction of non-uniform attenuation: a phantom study. N Nucl Med. 1995;36:46P. Abstract.
    • (1995) N Nucl Med. , vol.36
    • Eror, E.L.1    DeMan, P.2    Liu, Y.-H.3    Heller, E.N.4    Sinusas, A.J.5    Wackers, F.J.T.6
  • 35
    • 0006736307 scopus 로고    scopus 로고
    • Effects of attenuation corrected SPECT myocardial perfusion imaging on diagnostic accuracy: Results of a multicenter trial
    • Abstract
    • Hendel R, Berman D, Follansbee W, Heller G, Mahmarian J, Cullom J, Kiat H. Effects of attenuation corrected SPECT myocardial perfusion imaging on diagnostic accuracy: results of a multicenter trial. Circulation. 1996;94(suppl I):I-303. Abstract.
    • (1996) Circulation , vol.94 , Issue.SUPPL. I
    • Hendel, R.1    Berman, D.2    Follansbee, W.3    Heller, G.4    Mahmarian, J.5    Cullom, J.6    Kiat, H.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.