Volumn 112, Issue 5, 1999, Pages 456-460

Mechanical and histological analysis of bone-pedicle screw interface in vivo: Titanium versus stainless steel

Author keywords

Histomorphometry; Mechanical testing; Pedicle screw; Spinal fusion; Stainless steel; Titanium

Indexed keywords

STAINLESS STEEL; TITANIUM;

EID: 0033123442     PISSN: 03666999     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (22)

References (11)
  • 2
    • 0024764141 scopus 로고
    • Roentgenographic and biomechanic analysis of lumbar fusion: A canine model
    • Gurr KR, McAfee PC, Warden KE, et al. Roentgenographic and biomechanic analysis of lumbar fusion: a canine model. J Orthop Res 1989;7:838-848.
    • (1989) J Orthop Res , vol.7 , pp. 838-848
    • Gurr, K.R.1    McAfee, P.C.2    Warden, K.E.3
  • 3
    • 0025110326 scopus 로고
    • Effect of spinal construct stiffness on early fusion mass incorporation: Experimental study
    • Johnston CE, Ashman RB, Baird AM, et al. Effect of spinal construct stiffness on early fusion mass incorporation: experimental study. Spine 1990;15:908-912.
    • (1990) Spine , vol.15 , pp. 908-912
    • Johnston, C.E.1    Ashman, R.B.2    Baird, A.M.3
  • 4
    • 0023837451 scopus 로고
    • Mechanical testing of spine instrumentation
    • Ashman RB, Birch JG, Bone LB, et al. Mechanical testing of spine instrumentation. Clin Orthop 1988;227:113-125.
    • (1988) Clin Orthop , vol.227 , pp. 113-125
    • Ashman, R.B.1    Birch, J.G.2    Bone, L.B.3
  • 5
    • 0026637677 scopus 로고
    • Magnetic resonance imaging after pedicular screw fixation of the spine
    • Ebraheim NA, Savolaine ER, Stitgen SH, et al. Magnetic resonance imaging after pedicular screw fixation of the spine. Clin Orthop 1992;279:133-137
    • (1992) Clin Orthop , vol.279 , pp. 133-137
    • Ebraheim, N.A.1    Savolaine, E.R.2    Stitgen, S.H.3
  • 6
    • 0025240048 scopus 로고
    • Removal torques of small screws of steel and titanium with different surface
    • Eulenberger J, Steinemann SG. Removal torques of small screws of steel and titanium with different surface. Unfallchirurg 1990; 93:96-99.
    • (1990) Unfallchirurg , vol.93 , pp. 96-99
    • Eulenberger, J.1    Steinemann, S.G.2
  • 7
    • 85081464729 scopus 로고
    • Bone screw fixation in vivo: Axial pullout strength and histological analysis of interface
    • November 6-8; San Diego, California
    • Rivard CH, Rhalmi S. Bone screw fixation in vivo: axial pullout strength and histological analysis of interface. Proceedings of Combined Orthopedic Research Societies Meeting; 1995, November 6-8; San Diego, California.
    • (1995) Proceedings of Combined Orthopedic Research Societies Meeting
    • Rivard, C.H.1    Rhalmi, S.2
  • 8
    • 0028819606 scopus 로고
    • Lumbar pedicle screw salvage: Pullout testing of three different pedicle screw designs
    • Mclain RF, Fry MF, Moseley TA, et al. Lumbar pedicle screw salvage: pullout testing of three different pedicle screw designs. J Spinal Disord 1995;8:62-68.
    • (1995) J Spinal Disord , vol.8 , pp. 62-68
    • McLain, R.F.1    Fry, M.F.2    Moseley, T.A.3
  • 9
    • 0016810830 scopus 로고
    • Incorporation of stainless steel, titanium and vitallium in bone
    • Linder L, Lundskog J. Incorporation of stainless steel, titanium and vitallium in bone. Injury 1975;6:277-285.
    • (1975) Injury , vol.6 , pp. 277-285
    • Linder, L.1    Lundskog, J.2
  • 10
    • 0025144411 scopus 로고
    • A histological study of stainless steel and titanium screws in bone
    • Millar BG, Frame JW, Browne RM. A histological study of stainless steel and titanium screws in bone. J Oral Maxillofac Surg 1990;28:92-95.
    • (1990) J Oral Maxillofac Surg , vol.28 , pp. 92-95
    • Millar, B.G.1    Frame, J.W.2    Browne, R.M.3
  • 11
    • 0022974519 scopus 로고
    • An ultrastructural characterization of the interface between bone and spluttered titanium or stainless steel surface
    • Albrektsson T, Hansson HA. An ultrastructural characterization of the interface between bone and spluttered titanium or stainless steel surface. Biomaterials 1986;7:201-205.
    • (1986) Biomaterials , vol.7 , pp. 201-205
    • Albrektsson, T.1    Hansson, H.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.