-
1
-
-
0030148130
-
Clinical effectiveness of implant-supported single tooth replacement: the Toronto Study
-
Avivi-Arber L., and Zarb G.A. Clinical effectiveness of implant-supported single tooth replacement: the Toronto Study. Int J Oral Maxillofac Implants 11 (1996) 311-321
-
(1996)
Int J Oral Maxillofac Implants
, vol.11
, pp. 311-321
-
-
Avivi-Arber, L.1
Zarb, G.A.2
-
2
-
-
0030184468
-
Osseointegrated implants for single-tooth replacement a prospective 5-year multicenter study
-
Henry P.J., Laney W.R., Jemt T., Harris D., Krogh P.H., Polizzi G., et al. Osseointegrated implants for single-tooth replacement a prospective 5-year multicenter study. Int J Oral Maxillofac Implants 11 (1996) 450-455
-
(1996)
Int J Oral Maxillofac Implants
, vol.11
, pp. 450-455
-
-
Henry, P.J.1
Laney, W.R.2
Jemt, T.3
Harris, D.4
Krogh, P.H.5
Polizzi, G.6
-
3
-
-
0028185281
-
Osseointegrated implants for single-tooth replacement progress report from a multicenter prospective study after 3 years
-
Laney W.R., Jemt T., Harris D., Henry P.J., Krogh P.H., Polizzi G., et al. Osseointegrated implants for single-tooth replacement progress report from a multicenter prospective study after 3 years. Int J Oral Maxillofac Implants 9 (1994) 49-54
-
(1994)
Int J Oral Maxillofac Implants
, vol.9
, pp. 49-54
-
-
Laney, W.R.1
Jemt, T.2
Harris, D.3
Henry, P.J.4
Krogh, P.H.5
Polizzi, G.6
-
4
-
-
0028390422
-
Complications and maintenance requirements for fixed prostheses and overdentures in the edentulous mandible: a 5-year report
-
Hemmings K.W., Schmitt A., and Zarb G.A. Complications and maintenance requirements for fixed prostheses and overdentures in the edentulous mandible: a 5-year report. Int J Oral Maxillofac Implants 9 (1994) 191-196
-
(1994)
Int J Oral Maxillofac Implants
, vol.9
, pp. 191-196
-
-
Hemmings, K.W.1
Schmitt, A.2
Zarb, G.A.3
-
5
-
-
0028390316
-
Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years
-
Kallus T., and Bessing C. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants 9 (1994) 169-178
-
(1994)
Int J Oral Maxillofac Implants
, vol.9
, pp. 169-178
-
-
Kallus, T.1
Bessing, C.2
-
7
-
-
0028451094
-
Tightening characteristics for screwed joints in osseointegrated dental implants
-
Burguete R.L., Johns R.B., King T., and Patterson E.A. Tightening characteristics for screwed joints in osseointegrated dental implants. Prosthet Dent 71 (1994) 592-599
-
(1994)
Prosthet Dent
, vol.71
, pp. 592-599
-
-
Burguete, R.L.1
Johns, R.B.2
King, T.3
Patterson, E.A.4
-
8
-
-
0026829920
-
Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants
-
Patterson E.A., and Johns R.B. Theoretical analysis of the fatigue life of fixture screws in osseointegrated dental implants. Int J Oral Maxillofac Implants 7 (1992) 26-33
-
(1992)
Int J Oral Maxillofac Implants
, vol.7
, pp. 26-33
-
-
Patterson, E.A.1
Johns, R.B.2
-
9
-
-
0029302999
-
Nonlinear contact analysis of preload in dental implant screws
-
Sakaguchi R.L., and Borgersen S.E. Nonlinear contact analysis of preload in dental implant screws. Int J Oral Maxillofac Implants 10 (1995) 295-302
-
(1995)
Int J Oral Maxillofac Implants
, vol.10
, pp. 295-302
-
-
Sakaguchi, R.L.1
Borgersen, S.E.2
-
10
-
-
0027829234
-
Nonlinear finite element contact analysis of dental implant components
-
Sakaguchi R.L., and Borgersen S.E. Nonlinear finite element contact analysis of dental implant components. Int J Oral Maxillofac Implants 8 (1993) 655-661
-
(1993)
Int J Oral Maxillofac Implants
, vol.8
, pp. 655-661
-
-
Sakaguchi, R.L.1
Borgersen, S.E.2
-
11
-
-
0030098964
-
The effect of implant/abutment hexagonal misfit on screw joint stability
-
Binon P.P. The effect of implant/abutment hexagonal misfit on screw joint stability. Int J Prosthodont 9 (1996) 149-160
-
(1996)
Int J Prosthodont
, vol.9
, pp. 149-160
-
-
Binon, P.P.1
-
12
-
-
0039829366
-
The role of screws in implant systems
-
(Suppl)
-
(Suppl). Binon P.P., Sutter F., Beaty K., Brunski J., Gulbransen H., and Weiner R. The role of screws in implant systems. Int J Oral Maxillofac Implants 9 (1994) 48-63
-
(1994)
Int J Oral Maxillofac Implants
, vol.9
, pp. 48-63
-
-
Binon, P.P.1
Sutter, F.2
Beaty, K.3
Brunski, J.4
Gulbransen, H.5
Weiner, R.6
-
13
-
-
0027616941
-
On clinical loading of osseointegrated implants. A methodological and clinical study
-
Glantz P.O., Rangert B., Svensson A., Stafford G.D., Arnvidarson B., Randow K., et al. On clinical loading of osseointegrated implants. A methodological and clinical study. Clin Oral Implants Res 4 (1993) 99-105
-
(1993)
Clin Oral Implants Res
, vol.4
, pp. 99-105
-
-
Glantz, P.O.1
Rangert, B.2
Svensson, A.3
Stafford, G.D.4
Arnvidarson, B.5
Randow, K.6
-
15
-
-
0026921977
-
Loads and designs of screw joints for single crowns supported by osseointegrated implants
-
Jorneus L., Jemt T., and Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants 7 (1992) 353-359
-
(1992)
Int J Oral Maxillofac Implants
, vol.7
, pp. 353-359
-
-
Jorneus, L.1
Jemt, T.2
Carlsson, L.3
-
17
-
-
0029366883
-
A comparison of implant/prosthesis loading with four clinical variables
-
Weinberg L.A., and Kruger B. A comparison of implant/prosthesis loading with four clinical variables. Int J Prosthodont 8 (1995) 421-433
-
(1995)
Int J Prosthodont
, vol.8
, pp. 421-433
-
-
Weinberg, L.A.1
Kruger, B.2
-
18
-
-
0031205159
-
Reintegration of mobilized titanium implants. An experimental study in rabbit tibia
-
Ivanoff C.J., Sennerby L., and Lekholm U. Reintegration of mobilized titanium implants. An experimental study in rabbit tibia. Int J Oral Maxillofac Surg 26 (1997) 310-315
-
(1997)
Int J Oral Maxillofac Surg
, vol.26
, pp. 310-315
-
-
Ivanoff, C.J.1
Sennerby, L.2
Lekholm, U.3
-
19
-
-
0026167719
-
Early failures in 4,641 consecutively placed Brånemark dental implants: a study from stage 1 to the connection of completed prostheses
-
Friberg B., Jemt T., and Lekholm U. Early failures in 4,641 consecutively placed Brånemark dental implants: a study from stage 1 to the connection of completed prostheses. Int J Oral Maxillofac Implants 6 (1991) 142-146
-
(1991)
Int J Oral Maxillofac Implants
, vol.6
, pp. 142-146
-
-
Friberg, B.1
Jemt, T.2
Lekholm, U.3
-
20
-
-
0026810954
-
A six-year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism
-
Naert I., Quirynen M., van Steenberghe D., and Darius P. A six-year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism. J Prosthet Dent 67 (1992) 236-245
-
(1992)
J Prosthet Dent
, vol.67
, pp. 236-245
-
-
Naert, I.1
Quirynen, M.2
van Steenberghe, D.3
Darius, P.4
|