메뉴 건너뛰기




Volumn 48, Issue 1, 1999, Pages 61-69

Morphology of in vitro generated ultrahigh molecular weight polyethylene wear particles as a function of contact conditions and material parameters

Author keywords

Contact stress; Orientation; Particles; UHMWPE; Wear

Indexed keywords

BIOMATERIALS; INTERFACES (MATERIALS); MOLECULAR ORIENTATION; MORPHOLOGY; PARTICLES (PARTICULATE MATTER); STRESS ANALYSIS; SURFACE ROUGHNESS; ULTRAHIGH MOLECULAR WEIGHT POLYETHYLENES; WEAR OF MATERIALS;

EID: 0033105468     PISSN: 00219304     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1097-4636(1999)48:1<61::AID-JBM11>3.0.CO;2-U     Document Type: Article
Times cited : (16)

References (28)
  • 2
    • 0022389660 scopus 로고
    • Granulomatous resections and cystic bony destruction associated with high wear rates in total knee replacements
    • Dannenmaier WC, Haynes DW, Nelson CL. Granulomatous resections and cystic bony destruction associated with high wear rates in total knee replacements. Clin Orthop 1985; 198:225-230.
    • (1985) Clin Orthop , vol.198 , pp. 225-230
    • Dannenmaier, W.C.1    Haynes, D.W.2    Nelson, C.L.3
  • 4
    • 0023147355 scopus 로고
    • Foreign body reaction to polymeric debris following total hip arthroplasty
    • Maquire JK, Cosica MF, Lynch MH. Foreign body reaction to polymeric debris following total hip arthroplasty. Clin Orthop 1987;216:213-233.
    • (1987) Clin Orthop , vol.216 , pp. 213-233
    • Maquire, J.K.1    Cosica, M.F.2    Lynch, M.H.3
  • 5
    • 0023331616 scopus 로고
    • Tissue reactions to wear products from polyacetyl (Delrin) and UHMW polyethylene in total hip replacement
    • Mathieson EB, Lindgren JU, Reinholt FP, et al. Tissue reactions to wear products from polyacetyl (Delrin) and UHMW polyethylene in total hip replacement. J Biomed Mater Res 1987;21:446-459.
    • (1987) J Biomed Mater Res , vol.21 , pp. 446-459
    • Mathieson, E.B.1    Lindgren, J.U.2    Reinholt, F.P.3
  • 6
    • 0028836831 scopus 로고
    • The origin of submicron polyethylene wear debris in total hip arthroplasty
    • McKellop HA, Campbell P, Park SH, et al. The origin of submicron polyethylene wear debris in total hip arthroplasty. Clin Orthop Rel Res 1995;311:3-20.
    • (1995) Clin Orthop Rel Res , vol.311 , pp. 3-20
    • McKellop, H.A.1    Campbell, P.2    Park, S.H.3
  • 7
    • 0026550544 scopus 로고
    • The mechanism of loosening of cemented acetabular components in total hip arthroplasty
    • Schmalzried TP, Kwong LM, Jasty M, et al. The mechanism of loosening of cemented acetabular components in total hip arthroplasty. CORR 1992;274:60-78.
    • (1992) CORR , vol.274 , pp. 60-78
    • Schmalzried, T.P.1    Kwong, L.M.2    Jasty, M.3
  • 8
    • 0025222261 scopus 로고
    • Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles
    • Willert HG, Bertram H, Buchhorn GH. Osteolysis in alloarthroplasty of the hip. The role of ultra-high molecular weight polyethylene wear particles. Clin Orthop Rel Res 1990;258: 95-107.
    • (1990) Clin Orthop Rel Res , vol.258 , pp. 95-107
    • Willert, H.G.1    Bertram, H.2    Buchhorn, G.H.3
  • 9
    • 0025412672 scopus 로고
    • The histological effects of implantation of different sizes of polyethylene particles in the rabbit tibia
    • Goodman SB, Fornasier VL, Lee J, Kei J. The histological effects of implantation of different sizes of polyethylene particles in the rabbit tibia. J Biomed Mater Res 1990;24:517-524.
    • (1990) J Biomed Mater Res , vol.24 , pp. 517-524
    • Goodman, S.B.1    Fornasier, V.L.2    Lee, J.3    Kei, J.4
  • 10
    • 0030130840 scopus 로고    scopus 로고
    • Effect of size, concentration, surface area, and volume of PMMA particles on human macrophages in vitro
    • Gonzalez O, Smith RL, Goodman SB. Effect of size, concentration, surface area, and volume of PMMA particles on human macrophages in vitro. J Biomed Mater Res 1996;30: 463-473.
    • (1996) J Biomed Mater Res , vol.30 , pp. 463-473
    • Gonzalez, O.1    Smith, R.L.2    Goodman, S.B.3
  • 13
    • 0028501856 scopus 로고
    • Polyethylene wear debris and tissue reactions in knee as compared to hip prostheses
    • Schmalzried TP. Polyethylene wear debris and tissue reactions in knee as compared to hip prostheses. J Appl Biomater 1994;5:185-190.
    • (1994) J Appl Biomater , vol.5 , pp. 185-190
    • Schmalzried, T.P.1
  • 15
    • 0027983089 scopus 로고
    • Composition and morphology of wear debris in failed uncemented total hip replacement
    • Shanbahg AS, Jacobs JJ, Giant TT, et al. Composition and morphology of wear debris in failed uncemented total hip replacement. J Bone Joint Surg 1994;76B:60-67.
    • (1994) J Bone Joint Surg , vol.76 B , pp. 60-67
    • Shanbahg, A.S.1    Jacobs, J.J.2    Giant, T.T.3
  • 17
    • 0028929254 scopus 로고
    • Isolation of predominantly submicron sized UHMWPE wear particles from periprosthetic tissues
    • Campbell P, Ma S, Yeom B, et al. Isolation of predominantly submicron sized UHMWPE wear particles from periprosthetic tissues. J Biomed Mater Res 1995;29:127-131.
    • (1995) J Biomed Mater Res , vol.29 , pp. 127-131
    • Campbell, P.1    Ma, S.2    Yeom, B.3
  • 20
    • 0026152934 scopus 로고
    • Fractal parameters and computer image analysis applied to wear particles isolated by ferrography
    • Kirk TB, Stachowiak GW, Batchelor, AW. Fractal parameters and computer image analysis applied to wear particles isolated by ferrography. Wear 1991;145:347-365.
    • (1991) Wear , vol.145 , pp. 347-365
    • Kirk, T.B.1    Stachowiak, G.W.2    Batchelor, A.W.3
  • 21
    • 0003446682 scopus 로고    scopus 로고
    • Bethesda, MD: National Institutes of Health
    • Rasband W. NIH Image. Bethesda, MD: National Institutes of Health; 1996.
    • (1996) NIH Image
    • Rasband, W.1
  • 23
    • 0025834740 scopus 로고
    • Low rate of wear of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy
    • Kumar P, Oka M, Ikeuchi K, et al. Low rate of wear of UHMWPE against zirconia ceramic (Y-PSZ) in comparison to alumina ceramic and SUS 316L alloy. J Biomed Mater Res 1991;25:813-828.
    • (1991) J Biomed Mater Res , vol.25 , pp. 813-828
    • Kumar, P.1    Oka, M.2    Ikeuchi, K.3
  • 24
    • 0018034893 scopus 로고
    • Wear characteristics of UHMW polyethylene: A method of accurately measuring extremely low wear rates
    • McKellop HA, Clarke IC, Markolf KL, Amstutz HC. Wear characteristics of UHMW polyethylene: a method of accurately measuring extremely low wear rates. J Biomed Mater Res 1978;12:895-927.
    • (1978) J Biomed Mater Res , vol.12 , pp. 895-927
    • McKellop, H.A.1    Clarke, I.C.2    Markolf, K.L.3    Amstutz, H.C.4
  • 25
    • 0029253653 scopus 로고
    • The influence of contact stress on the wear of UHMWPE for total hip prostheses
    • Barbour PSM, Barton DC, Fisher J. The influence of contact stress on the wear of UHMWPE for total hip prostheses. Wear 1995;181-183:250-257.
    • (1995) Wear , vol.181-183 , pp. 250-257
    • Barbour, P.S.M.1    Barton, D.C.2    Fisher, J.3
  • 27
    • 0019914242 scopus 로고
    • The wear of high molecular weight polyethylene - Part II: The effects of reciprocating motion, orientation of the polyethylene, and a preliminary study of the wear of polyethylene against itself
    • Brown KJ, Atkinson JR, Dowson D. The wear of high molecular weight polyethylene - part II: the effects of reciprocating motion, orientation of the polyethylene, and a preliminary study of the wear of polyethylene against itself. J Lubrication Technol 1982;104:17-22.
    • (1982) J Lubrication Technol , vol.104 , pp. 17-22
    • Brown, K.J.1    Atkinson, J.R.2    Dowson, D.3
  • 28
    • 0029255360 scopus 로고
    • Wear mechanisms of UHMWPE in total joint replacements
    • Wang A. Wear mechanisms of UHMWPE in total joint replacements. Wear 1995;181-183:241-249.
    • (1995) Wear , vol.181-183 , pp. 241-249
    • Wang, A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.