메뉴 건너뛰기




Volumn 91, Issue 2-3, 1999, Pages 95-102

ICR protocol: Alternative treatment of parasite sample data

Author keywords

[No Author keywords available]

Indexed keywords

BIOASSAY; EXTRAPOLATION; FLUORESCENCE; IMMUNOLOGY; MATHEMATICAL MODELS; MEASUREMENT ERRORS; POISSON DISTRIBUTION;

EID: 0033097330     PISSN: 0003150X     EISSN: None     Source Type: Journal    
DOI: 10.1002/j.1551-8833.1999.tb08603.x     Document Type: Article
Times cited : (10)

References (25)
  • 1
    • 0001438275 scopus 로고    scopus 로고
    • National Primary Drinking Water Regulations; Monitoring Requirements for Public Drinking Water Supplies; Final Rule
    • USEPA. National Primary Drinking Water Regulations; Monitoring Requirements for Public Drinking Water Supplies; Final Rule. Fed. Reg., 61:94:24354 (1996).
    • (1996) Fed. Reg. , vol.61 , Issue.94 , pp. 24354
  • 2
    • 0004163811 scopus 로고    scopus 로고
    • EPA/600/R-95/178, Ofce. of Research and Development, Natl. Exposure Research Lab., Cincinnati
    • FOUT, G.S. ET AL. ICR Microbial Laboratory Manual. EPA/600/R-95/178, Ofce. of Research and Development, Natl. Exposure Research Lab., Cincinnati (1996).
    • (1996) ICR Microbial Laboratory Manual
    • Fout, G.S.1
  • 4
    • 0028868116 scopus 로고
    • Cryptosporidium Contamination of Water in the USa and UK: A Mini-Review
    • LISLE, J.T. & ROSE, J.B. Cryptosporidium Contamination of Water in the USA and UK: A Mini-Review. Jour. Water SRT - Aqua, 44:103 (1995).
    • (1995) Jour. Water SRT - Aqua , vol.44 , pp. 103
    • Lisle, J.T.1    Rose, J.B.2
  • 6
    • 0026358601 scopus 로고
    • Survey of Potable Water Supplies for Cryptosporidium and Giardia
    • ROSE, J.B.; GERBA, C.P.; & JAKUBOWSKI, W. Survey of Potable Water Supplies for Cryptosporidium and Giardia. Envir. Sci. & Technol., 25:1393 (1991).
    • (1991) Envir. Sci. & Technol. , vol.25 , pp. 1393
    • Rose, J.B.1    Gerba, C.P.2    Jakubowski, W.3
  • 9
    • 0001274753 scopus 로고
    • Drinking Water; National Primary Drinking Water Regulations; Filtration, Disinfection; Turbidity, Giardia lamblia, Viruses, Legionella, and Heterotrophic Bacteria
    • June 29
    • USEPA. Drinking Water; National Primary Drinking Water Regulations; Filtration, Disinfection; Turbidity, Giardia lamblia, Viruses, Legionella, and Heterotrophic Bacteria. Fed. Reg., 54:124:27486 (June 29, 1989).
    • (1989) Fed. Reg. , vol.54 , Issue.124 , pp. 27486
  • 11
    • 0000931407 scopus 로고    scopus 로고
    • National Primary Drinking Water Regulations; Interim Enhanced Surface Water Treatment; Final Rule
    • Dec. 16
    • USEPA. National Primary Drinking Water Regulations; Interim Enhanced Surface Water Treatment; Final Rule. Fed. Reg., 63:241:69478 (Dec. 16, 1998).
    • (1998) Fed. Reg. , vol.63 , Issue.241 , pp. 69478
  • 12
    • 0029911362 scopus 로고    scopus 로고
    • Developments in Microbiological Risk Assessment Models for Drinking Water - A Short Review
    • GALE, P. Developments in Microbiological Risk Assessment Models for Drinking Water - A Short Review. Jour. Applied Bacteriol., 81:403 (1996).
    • (1996) Jour. Applied Bacteriol. , vol.81 , pp. 403
    • Gale, P.1
  • 15
    • 0002290170 scopus 로고
    • Protozoan Monitoring: From the ICR to the ESWTR
    • Aug.
    • CROCKETT, C.S. & HAAS, C.N. Protozoan Monitoring: From the ICR to the ESWTR. Jour. AWWA, 87:8:50 (Aug. 1995).
    • (1995) Jour. AWWA , vol.87 , Issue.8 , pp. 50
    • Crockett, C.S.1    Haas, C.N.2
  • 17
    • 0030615884 scopus 로고    scopus 로고
    • Assessment of the Risk of Infection by Cryptosporidium or Giardia in Drinking Water from a Surface Water Source
    • TEUNIS, P.F.M. ET AL. Assessment of the Risk of Infection by Cryptosporidium or Giardia in Drinking Water From a Surface Water Source. Water Res., 31:6:1333 (1997).
    • (1997) Water Res. , vol.31 , Issue.6 , pp. 1333
    • Teunis, P.F.M.1
  • 22
    • 0030481029 scopus 로고    scopus 로고
    • A Statistical Method for Determining the Reliability of the Analytical Results in the Detection of Cryptosporidium and Giardia in Water
    • NAHRSTEDT, A. & GIMBEL, R. A Statistical Method for Determining the Reliability of the Analytical Results in the Detection of Cryptosporidium and Giardia in Water. Jour. Water SRT - Aqua, 45:101 (1996).
    • (1996) Jour. Water SRT - Aqua , vol.45 , pp. 101
    • Nahrstedt, A.1    Gimbel, R.2
  • 23
    • 0032211316 scopus 로고    scopus 로고
    • Determining Average Concentrations of Cryptosporidium and Other Pathogens in Water
    • PARKHURST, D.F. & STERN, D.A. Determining Average Concentrations of Cryptosporidium and Other Pathogens in Water. Envir. Sci. & Technol., 32:3424 (1998).
    • (1998) Envir. Sci. & Technol. , vol.32 , pp. 3424
    • Parkhurst, D.F.1    Stern, D.A.2
  • 24
    • 0028427713 scopus 로고
    • Commercial Labs: How Accurate Are They?
    • May
    • CLANCY, J.L.; GOLLNITZ, W.D.; & TABIB, Z. Commercial Labs: How Accurate Are They? Jour. AWWA, 86:5:89 (May 1994).
    • (1994) Jour. AWWA , vol.86 , Issue.5 , pp. 89
    • Clancy, J.L.1    Gollnitz, W.D.2    Tabib, Z.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.