메뉴 건너뛰기




Volumn 14, Issue 2, 1999, Pages 278-281

Accuracy of an electric torque-limiting device for implants

Author keywords

Biomechanics; Implants; Prosthodontics; Torque control

Indexed keywords

ANALYSIS OF VARIANCE; ARTICLE; DENTAL CARE; DENTAL EQUIPMENT; INSTRUMENTATION; REPRODUCIBILITY; TOOTH IMPLANTATION; TORQUE;

EID: 0033089292     PISSN: 08822786     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (31)

References (13)
  • 2
    • 0039977027 scopus 로고
    • Making fastened joints reliable…ways to keep ‘em tight
    • Rodkey E. Making fastened joints reliable…ways to keep ‘em tight. Assembly Eng 1977;24-27.
    • (1977) Assembly Eng , pp. 24-27
    • Rodkey, E.1
  • 3
    • 0016887225 scopus 로고
    • Development of design charts for bolts preloaded up to the plastic range
    • Motash N. Development of design charts for bolts preloaded up to the plastic range. J Eng Ind 1976;98: 849-851.
    • (1976) J Eng Ind , vol.98 , pp. 849-851
    • Motash, N.1
  • 4
    • 0028389987 scopus 로고
    • Torque generated by handle screwdrivers and mechanical torquing devices for osseointegrated implants
    • Goheen KL, Vermilyea SG, Vossoughi J, Agar JR. Torque generated by handle screwdrivers and mechanical torquing devices for osseointegrated implants. Int J Oral Maxillofac Implants 1994;9: 149-155.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 149-155
    • Goheen, K.L.1    Vermilyea, S.G.2    Vossoughi, J.3    Agar, J.R.4
  • 5
    • 0027572131 scopus 로고
    • Providing optimum torque to implant prostheses: A pilot study
    • Spring
    • Jaarda MJ, Razzoog ME, Gratton DG. Providing optimum torque to implant prostheses: A pilot study. Implant Dent 1993;Spring(2): 50-52.
    • (1993) Implant Dent , Issue.2 , pp. 50-52
    • Jaarda, M.J.1    Razzoog, M.E.2    Gratton, D.G.3
  • 8
    • 84995740403 scopus 로고
    • The right torque for the right job
    • Edgren S. The right torque for the right job. Nobelpharma News 1992;1: 5.
    • (1992) Nobelpharma News , vol.1 , pp. 5
    • Edgren, S.1
  • 9
    • 0029678060 scopus 로고    scopus 로고
    • Effects of infection control procedures on the accuracy of a mechanical torque wrench system for implant restorations
    • Dellinges M, Curtis D. Effects of infection control procedures on the accuracy of a mechanical torque wrench system for implant restorations. J Prosthet Dent 1996;75: 93-98.
    • (1996) J Prosthet Dent , vol.75 , pp. 93-98
    • Dellinges, M.1    Curtis, D.2
  • 10
    • 84995806159 scopus 로고
    • Avoiding the pitfalls of torque measuring
    • Carlsson L. Avoiding the pitfalls of torque measuring. Nobelpharma News 1992;1: 5.
    • (1992) Nobelpharma News , vol.1 , pp. 5
    • Carlsson, L.1
  • 11
    • 0029302999 scopus 로고
    • Nonlinear contact analysis of preload in dental implant screws
    • Sakaguchi RL, Borgersen SE. Nonlinear contact analysis of preload in dental implant screws. Int J Oral Maxillofac Implants 1995;10: 295-302.
    • (1995) Int J Oral Maxillofac Implants , vol.10 , pp. 295-302
    • Sakaguchi, R.L.1    Borgersen, S.E.2
  • 12
    • 0026810954 scopus 로고
    • A six year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism
    • Naert I, Quirynen M, van Steenberghe D, Dariuw P. A six year prosthodontic study of 509 consecutively inserted implants for the treatment of partial edentulism. J Prosthet Dent 1992;67: 236-245.
    • (1992) J Prosthet Dent , vol.67 , pp. 236-245
    • Naert, I.1    Quirynen, M.2    van Steenberghe, D.3    Dariuw, P.4
  • 13
    • 0025471133 scopus 로고
    • The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part III: Problems and complications encountered
    • Zarb GA, Schmitt A. The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part III: Problems and complications encountered. J Prosthet Dent 1990;64: 185-194.
    • (1990) J Prosthet Dent , vol.64 , pp. 185-194
    • Zarb, G.A.1    Schmitt, A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.