메뉴 건너뛰기




Volumn 13, Issue 3, 1999, Pages 178-186

Influence of plate design on cortical bone perfusion and fracture healing in canine segmental tibial fractures

Author keywords

Biomechanics; Bone perfusion; Fracture healing; Plate fixation; Segmental fracture

Indexed keywords

ANIMAL; ARTICLE; BIOMECHANICS; BLOOD FLOW; BLOOD FLOW VELOCITY; BONE DENSITY; BONE PLATE; BONE REGENERATION; COMPARATIVE STUDY; DISEASE MODEL; DOG; EQUIPMENT DESIGN; FRACTURE HEALING; INSTRUMENTATION; LASER DOPPLER FLOWMETRY; METHODOLOGY; OSTEOSYNTHESIS; PATHOLOGY; PATHOPHYSIOLOGY; PHYSIOLOGY; RANDOMIZATION; TIBIA; TIBIA FRACTURE; VASCULARIZATION;

EID: 0033087361     PISSN: 08905339     EISSN: None     Source Type: Journal    
DOI: 10.1097/00005131-199903000-00005     Document Type: Article
Times cited : (31)

References (25)
  • 1
    • 0017577355 scopus 로고
    • The effect of fixation with intramedullary rods and plates on fractures site blood flow and bone remodelling
    • Barron SE, Robb RA, Taylor WF, et al. The effect of fixation with intramedullary rods and plates on fractures site blood flow and bone remodelling. J Bone Joint Surg 1977;59A:376-385.
    • (1977) J Bone Joint Surg , vol.59 A , pp. 376-385
    • Barron, S.E.1    Robb, R.A.2    Taylor, W.F.3
  • 2
    • 0002853165 scopus 로고
    • Porosity and remodelling of plated bone after internal fixation: Result of stress shielding or vascular damage?
    • ed by Docheyne P. Van der Perre G. Aubert AB, Amsterdam, Elsevier Science Publishers BV
    • Gautier E, Cordey J, Mathys R, et al. Porosity and remodelling of plated bone after internal fixation: result of stress shielding or vascular damage? In Biomaterials and Biomechanics 1983, ed by Docheyne P. Van der Perre G. Aubert AB, Amsterdam, Elsevier Science Publishers BV, 1984, pp 195-200.
    • (1984) Biomaterials and Biomechanics 1983 , pp. 195-200
    • Gautier, E.1    Cordey, J.2    Mathys, R.3
  • 3
    • 0026478065 scopus 로고
    • Blood flow and mechanical properties of healing bone
    • Grandnes O, Reikesràs O, Blood flow and mechanical properties of healing bone. Acta Orthop Scand 1992;63:487-491.
    • (1992) Acta Orthop Scand , vol.63 , pp. 487-491
    • Grandnes, O.1    Reikesràs, O.2
  • 4
    • 0019394993 scopus 로고
    • Effects of plates on cortical bone perfusion
    • Jacobs RR, Rahn BA, Perren SM. Effects of plates on cortical bone perfusion. J Trauma 1981;21:91-95.
    • (1981) J Trauma , vol.21 , pp. 91-95
    • Jacobs, R.R.1    Rahn, B.A.2    Perren, S.M.3
  • 5
    • 0031252838 scopus 로고    scopus 로고
    • Effect of stainless steel and titanium low-contact dynamic compression plate application on the vascularity and mechanical propesties of cortical bone after fracture
    • Jain R, Podworny N, Hearn T, Anderson GI, Schemitsch EH. Effect of stainless steel and titanium low-contact dynamic compression plate application on the vascularity and mechanical propesties of cortical bone after fracture. J Orthop Trauma 1997;11:490-495.
    • (1997) J Orthop Trauma , vol.11 , pp. 490-495
    • Jain, R.1    Podworny, N.2    Hearn, T.3    Anderson, G.I.4    Schemitsch, E.H.5
  • 6
    • 0041775331 scopus 로고
    • Comparative evaluation of the effect of plate design on fracture healing with special reference to cortical bone blood flow and biomechanical properties
    • Kowalski M, Schemitsch EH, Senft D, Harrington R, Rampoldi E, Swiontkowski M. Comparative evaluation of the effect of plate design on fracture healing with special reference to cortical bone blood flow and biomechanical properties. Trans Orthop Res Soc 1993;39:569.
    • (1993) Trans Orthop Res Soc , vol.39 , pp. 569
    • Kowalski, M.1    Schemitsch, E.H.2    Senft, D.3    Harrington, R.4    Rampoldi, E.5    Swiontkowski, M.6
  • 9
    • 0017083272 scopus 로고
    • Segmental tibial shaft fractures
    • Langård Ø, Bø O. Segmental tibial shaft fractures. Acta Orthop Scand 1976;47:351-357.
    • (1976) Acta Orthop Scand , vol.47 , pp. 351-357
    • Langård, Ø.1    Bø, O.2
  • 10
    • 0041775333 scopus 로고
    • Laser Doppler flowmetry for estimation of bone blood flow: Studies of reproducibility and correlation with microsphere technique
    • Lausten GS, Kiser T, Dahl B. Laser Doppler flowmetry for estimation of bone blood flow: studies of reproducibility and correlation with microsphere technique. J Orthop Res 1993;7:61-67.
    • (1993) J Orthop Res , vol.7 , pp. 61-67
    • Lausten, G.S.1    Kiser, T.2    Dahl, B.3
  • 11
    • 0016669606 scopus 로고
    • Blood flow and mineral deposition in cartine tibial fractures
    • Paradis GR, Kelly PJ. Blood flow and mineral deposition in cartine tibial fractures. J Bone Joint Surg 1975;57A:220-226.
    • (1975) J Bone Joint Surg , vol.57 A , pp. 220-226
    • Paradis, G.R.1    Kelly, P.J.2
  • 12
    • 0026333014 scopus 로고
    • The concept of biological plating using the limited contact-dynamic compression plate (LC-DCP)
    • Perren SM. The concept of biological plating using the limited contact-dynamic compression plate (LC-DCP). Inquiry 1991;22(Suppl). 1-41.
    • (1991) Inquiry , vol.22 , Issue.SUPPL. , pp. 1-41
    • Perren, S.M.1
  • 13
    • 0023809603 scopus 로고
    • Early temporary porosis, of bone induced by internal fixation implants: A reaction to necrosis, not to stress protection?
    • Perren SM, Cordey J. Rahn BA, et al. Early temporary porosis, of bone induced by internal fixation implants: a reaction to necrosis, not to stress protection? Clin Orthop 1988;232:139-151.
    • (1988) Clin Orthop , vol.232 , pp. 139-151
    • Perren, S.M.1    Cordey, J.2    Rahn, B.A.3
  • 14
    • 0025202404 scopus 로고
    • The limited contract dynamic compression plate
    • Perren SM, Klue K, Pohler O, et al. The limited contract dynamic compression plate. Arch Orthop Trauma Surg 1990;109:304-310.
    • (1990) Arch Orthop Trauma Surg , vol.109 , pp. 304-310
    • Perren, S.M.1    Klue, K.2    Pohler, O.3
  • 15
    • 0016164585 scopus 로고
    • Tibial blood supply in relation to fracture healing
    • Rhinelander FW. Tibial blood supply in relation to fracture healing. Clin Orthop 1974;105:34-81.
    • (1974) Clin Orthop , vol.105 , pp. 34-81
    • Rhinelander, F.W.1
  • 16
    • 0024698650 scopus 로고
    • Effect of muscle flap coverage on bone blood flow following devascularization of a segment of tibia: An experimental investigation in the dog
    • Richards RR, Schemitseb EH. Effect of muscle flap coverage on bone blood flow following devascularization of a segment of tibia: an experimental investigation in the dog. J Orthop Res 1989;7:550-558.
    • (1989) J Orthop Res , vol.7 , pp. 550-558
    • Richards, R.R.1    Schemitseb, E.H.2
  • 17
    • 0023204366 scopus 로고
    • The influence of muscle flap coverage on the repair of devascularized tibial cortex: An experimental investigation in the dog
    • Richards RR, Orsíni EC, Mahoney JL, et al. The influence of muscle flap coverage on the repair of devascularized tibial cortex: an experimental investigation in the dog. Plast Reconstr Surg 1987; 79:946-958.
    • (1987) Plast Reconstr Surg , vol.79 , pp. 946-958
    • Richards, R.R.1    Orsíni, E.C.2    Mahoney, J.L.3
  • 18
    • 0024331059 scopus 로고
    • The difficult healing of segmental fractures of the tibial shaft
    • Rommens PM, Coosemans W, Broos PLO. The difficult healing of segmental fractures of the tibial shaft. Arch Orthop Trauma Surg 1989;108:238-242.
    • (1989) Arch Orthop Trauma Surg , vol.108 , pp. 238-242
    • Rommens, P.M.1    Coosemans, W.2    Broos, P.L.O.3
  • 19
    • 0025454632 scopus 로고
    • Effect of fracture fixation on cortical bone blood flow
    • Smith SR, Brook JT, Kelly PJ. Effect of fracture fixation on cortical bone blood flow. J Orthop Res 1990;8:471-478.
    • (1990) J Orthop Res , vol.8 , pp. 471-478
    • Smith, S.R.1    Brook, J.T.2    Kelly, P.J.3
  • 20
    • 0023230987 scopus 로고
    • Laser doppler flowmetry for clinical evaluation of femoral head osteonecrosis
    • Swiontkowski MF, Ganz R, Schlegel U, Perren SM. Laser Doppler flowmetry for clinical evaluation of femoral head osteonecrosis. Clin Orthop 1987;218:181-185.
    • (1987) Clin Orthop , vol.218 , pp. 181-185
    • Swiontkowski, M.F.1    Ganz, R.2    Schlegel, U.3    Perren, S.M.4
  • 21
    • 0024311463 scopus 로고
    • Criteria for bone debridement in massive lower lamb trauma
    • Swiontkowski MF. Criteria for bone debridement in massive lower lamb trauma. Clin Orthop 1989;243:41-47.
    • (1989) Clin Orthop , vol.243 , pp. 41-47
    • Swiontkowski, M.F.1
  • 24
    • 0026686304 scopus 로고
    • The segmental tibial fracture
    • Woll TS, Dawelius PJ. The segmental tibial fracture Clin Orthop 1992;281:204-207.
    • (1992) Clin Orthop , vol.281 , pp. 204-207
    • Woll, T.S.1    Dawelius, P.J.2
  • 25
    • 0023768460 scopus 로고
    • The healing of canine vascularized segmental tibial osteotomies: The effect of retained endosteal circulation
    • Zdeblick TA, Shaffer JW, Field GA. The healing of canine vascularized segmental tibial osteotomies: the effect of retained endosteal circulation. Clin Orthop 1988;236:296-302.
    • (1988) Clin Orthop , vol.236 , pp. 296-302
    • Zdeblick, T.A.1    Shaffer, J.W.2    Field, G.A.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.