메뉴 건너뛰기




Volumn 14, Issue 2, 1999, Pages 229-235

Tethered mediator biosensor. Mediated electron transfer between redox enzyme and electrode via ferrocene anchored to electrode surface with long poly(oxyethylene) chain

Author keywords

Electron transfer; Reagentless biosensor; Redox enzyme; Tethered mediator

Indexed keywords

CATALYSIS; CHARGE TRANSFER; ELECTRODES; ENZYME IMMOBILIZATION; HYDROGEN PEROXIDE; IRON COMPOUNDS; POLYETHYLENE GLYCOLS; REACTION KINETICS; REDOX REACTIONS; REDUCTION; TIN COMPOUNDS;

EID: 0033083556     PISSN: 09565663     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0956-5663(98)00113-4     Document Type: Article
Times cited : (74)

References (28)
  • 2
    • 0012967523 scopus 로고
    • Direct electrical communication between chemically modified enzymes and metal electrodes. 1. Electron transfer from glucose oxidase to metal electrodes via electron relays, bound covalently to the enzyme
    • Degani Y., Heller A. Direct electrical communication between chemically modified enzymes and metal electrodes. 1. Electron transfer from glucose oxidase to metal electrodes via electron relays, bound covalently to the enzyme. J. Phys. Chem. 91:1987;1285-1289.
    • (1987) J. Phys. Chem. , vol.91 , pp. 1285-1289
    • Degani, Y.1    Heller, A.2
  • 3
    • 0346995667 scopus 로고
    • Direct electrical communication between chemically modified enzymes and metal electrodes. 2. Methods for bonding electron-transfer relays to glucose oxidase and D-amino acid oxidase
    • Degani Y., Heller A. Direct electrical communication between chemically modified enzymes and metal electrodes. 2. Methods for bonding electron-transfer relays to glucose oxidase and D-amino acid oxidase. J. Am. Chem. Soc. 110:1988;2615-2620.
    • (1988) J. Am. Chem. Soc. , vol.110 , pp. 2615-2620
    • Degani, Y.1    Heller, A.2
  • 4
    • 0001622162 scopus 로고    scopus 로고
    • Electroanalytical detection of glucose using a cyanometalate-modified electrode: Requirements for the oxidation of burried redox sites in glucose oxidase
    • Du G., Lin C., Bocarsly B. Electroanalytical detection of glucose using a cyanometalate-modified electrode: requirements for the oxidation of burried redox sites in glucose oxidase. Anal. Chem. 68:1996;796-806.
    • (1996) Anal. Chem. , vol.68 , pp. 796-806
    • Du, G.1    Lin, C.2    Bocarsly, B.3
  • 5
    • 0025366526 scopus 로고
    • Cross-linked redox gels containing glucose oxidase for amperometric biosensor applications
    • Gregg B.A., Heller A. Cross-linked redox gels containing glucose oxidase for amperometric biosensor applications. Anal. Chem. 62:1990;258-263.
    • (1990) Anal. Chem. , vol.62 , pp. 258-263
    • Gregg, B.A.1    Heller, A.2
  • 6
    • 33750428427 scopus 로고
    • Electrical connection of enzyme redox centers to electrodes
    • Heller A. Electrical connection of enzyme redox centers to electrodes. J. Phys. Chem. 96:1992;3579-3587.
    • (1992) J. Phys. Chem. , vol.96 , pp. 3579-3587
    • Heller, A.1
  • 7
    • 0027590869 scopus 로고
    • Amperometric biosensors based on three-dimensional hydrogel-forming epoxy networks
    • Heller A., Maiden R., Wang D.L. Amperometric biosensors based on three-dimensional hydrogel-forming epoxy networks. Sens. Actuators B. 13 14:1993;180-183.
    • (1993) Sens. Actuators B , vol.13-14 , pp. 180-183
    • Heller, A.1    Maiden, R.2    Wang, D.L.3
  • 8
    • 37049071683 scopus 로고
    • Simultaneous immobilization of glucose oxidase and a mediator in conducting polymer films
    • Iwakura, C., Kajiya, Y., Yoneyama, H., 1988. Simultaneous immobilization of glucose oxidase and a mediator in conducting polymer films. J. Chem. Soc. Chem. Commun. 1019-1020.
    • (1988) J. Chem. Soc. Chem. Commun. , pp. 1019-1020
    • Iwakura, C.1    Kajiya, Y.2    Yoneyama, H.3
  • 9
    • 84987471882 scopus 로고
    • An electrochemical sensor for hydrogen peroxide based on peroxidase adsorbed on a spectrographic graphite electrode
    • Jönsson G., Gorton L. An electrochemical sensor for hydrogen peroxide based on peroxidase adsorbed on a spectrographic graphite electrode. Electroanalysis. 1:1989;465-468.
    • (1989) Electroanalysis , vol.1 , pp. 465-468
    • Jönsson, G.1    Gorton, L.2
  • 10
    • 0345648786 scopus 로고
    • Simultaneous immobilization of glucose oxidase and hydroquinonesulfonic acid in polypyrrole films and its application to glucose sensor
    • Kajiya Y., Sugai H., Iwakura C., Yoneyama H. Simultaneous immobilization of glucose oxidase and hydroquinonesulfonic acid in polypyrrole films and its application to glucose sensor. Denki Kagaku Oyobi Kougyou Butsuri Kagaku. 56:1988;1110-1111.
    • (1988) Denki Kagaku Oyobi Kougyou Butsuri Kagaku , vol.56 , pp. 1110-1111
    • Kajiya, Y.1    Sugai, H.2    Iwakura, C.3    Yoneyama, H.4
  • 11
    • 0026861296 scopus 로고
    • L-α-Glycerophosphate and L-lactate electrodes base on the electrochemical "wiring" of oxidases
    • Katakis I., Heller A. L-α-Glycerophosphate and L-lactate electrodes base on the electrochemical "wiring" of oxidases. Anal. Chem. 64:1992;1008-1013.
    • (1992) Anal. Chem. , vol.64 , pp. 1008-1013
    • Katakis, I.1    Heller, A.2
  • 12
    • 0025641371 scopus 로고
    • Mediatorless peroxidase electrode and preparation of bienzyme sensors
    • Kulys J., Schmid R.D. Mediatorless peroxidase electrode and preparation of bienzyme sensors. Bioelectrochem. Bioenerg. 24:1990;305-311.
    • (1990) Bioelectrochem. Bioenerg. , vol.24 , pp. 305-311
    • Kulys, J.1    Schmid, R.D.2
  • 13
    • 0037640489 scopus 로고    scopus 로고
    • Minizymes. A new strategy for the development of the reagentless amperomtric biosensors based on direct electron-transfer processes
    • Lötzbeyer T., Schuhmann W., Schmidt H.-L. Minizymes. A new strategy for the development of the reagentless amperomtric biosensors based on direct electron-transfer processes. Bioelectrochem. Bioenerg. 42:1997;1-6.
    • (1997) Bioelectrochem. Bioenerg. , vol.42 , pp. 1-6
    • Lötzbeyer, T.1    Schuhmann, W.2    Schmidt, H.-L.3
  • 14
    • 0029005946 scopus 로고
    • A regenerable pseudo-reagentless glucose biosensor based on Nafion polymer and 1,1′-dimethylferricinium mediator
    • Luong J.H.T., Brown R.S. A regenerable pseudo-reagentless glucose biosensor based on Nafion polymer and 1,1′-dimethylferricinium mediator. Anal. Chim. Acta. 310:1995;419-427.
    • (1995) Anal. Chim. Acta , vol.310 , pp. 419-427
    • Luong, J.H.T.1    Brown, R.S.2
  • 16
    • 0026425799 scopus 로고
    • Amperometric glucose microelectrodes prepared through immobilization of glucose oxidase in hydrogels
    • Pishko M.V., Michael A.C., Heller A. Amperometric glucose microelectrodes prepared through immobilization of glucose oxidase in hydrogels. Anal. Chem. 63:1991;2268-2272.
    • (1991) Anal. Chem. , vol.63 , pp. 2268-2272
    • Pishko, M.V.1    Michael, A.C.2    Heller, A.3
  • 17
    • 0029166546 scopus 로고
    • Improving enzyme-electrode contacts by redox modification of cofactors
    • Riklin A., Katz K., Willner I., Stocker A., Buchkmann A.F. Improving enzyme-electrode contacts by redox modification of cofactors. Nature (London). 376:1995;672-675.
    • (1995) Nature (London) , vol.376 , pp. 672-675
    • Riklin, A.1    Katz, K.2    Willner, I.3    Stocker, A.4    Buchkmann, A.F.5
  • 18
    • 0000225567 scopus 로고
    • Electron transfer between glucose oxidase and electrodes via redox medators bound with flexible chains to enzyme surface
    • Schumann W., Ohara T.J., Schmidt H.L., Heller A. Electron transfer between glucose oxidase and electrodes via redox medators bound with flexible chains to enzyme surface. J. Am. Chem. Soc. 113:1991;1394-1397.
    • (1991) J. Am. Chem. Soc. , vol.113 , pp. 1394-1397
    • Schumann, W.1    Ohara, T.J.2    Schmidt, H.L.3    Heller, A.4
  • 19
    • 0024764103 scopus 로고
    • Enzyme monolayer- And bilayer-modified tin oxide electrodes for the determination of hydrogen peroxide and glucose
    • Tatsuma T., Okawa Y., Watanabe T. Enzyme monolayer- and bilayer-modified tin oxide electrodes for the determination of hydrogen peroxide and glucose. Anal. Chem. 61:1989;2352-2355.
    • (1989) Anal. Chem. , vol.61 , pp. 2352-2355
    • Tatsuma, T.1    Okawa, Y.2    Watanabe, T.3
  • 20
    • 0013352350 scopus 로고
    • Enzyme monolayer- And bilayer-modified electrodes with diaphorase and dehydrogenase
    • Tatsuma T., Watanabe T. Enzyme monolayer- and bilayer-modified electrodes with diaphorase and dehydrogenase. J. Electroanal. Chem. 310:1991;149-157.
    • (1991) J. Electroanal. Chem. , vol.310 , pp. 149-157
    • Tatsuma, T.1    Watanabe, T.2
  • 21
    • 0025977574 scopus 로고
    • Oxidase/peroxidase bilayer-modified electrodes as sensors for lactate, pyruvate, cholesterol and uric acid
    • Tatsuma T., Watanabe T. Oxidase/peroxidase bilayer-modified electrodes as sensors for lactate, pyruvate, cholesterol and uric acid. Anal. Chim. Acta. 242:1991;85-89.
    • (1991) Anal. Chim. Acta , vol.242 , pp. 85-89
    • Tatsuma, T.1    Watanabe, T.2
  • 22
    • 0026211168 scopus 로고
    • Peroxidase model electrodes: Heme peptide modified electrodes as reagentless sensors for hydrogen peroxide
    • Tatsuma T., Watanabe T. Peroxidase model electrodes: heme peptide modified electrodes as reagentless sensors for hydrogen peroxide. Anal. Chem. 63:1991;1580-1585.
    • (1991) Anal. Chem. , vol.63 , pp. 1580-1585
    • Tatsuma, T.1    Watanabe, T.2
  • 23
    • 0027119851 scopus 로고
    • Model analysis of enzyme monolayer- And bilayer-modified electrodes: The steady-state response
    • Tatsuma T., Watanabe T. Model analysis of enzyme monolayer- and bilayer-modified electrodes: the steady-state response. Anal. Chem. 64:1992;625-630.
    • (1992) Anal. Chem. , vol.64 , pp. 625-630
    • Tatsuma, T.1    Watanabe, T.2
  • 24
    • 0027119818 scopus 로고
    • Model analysis of enzyme monolayer- And bilayer-modified electrodes: The transient response
    • Tatsuma T., Watanabe T., Okawa Y. Model analysis of enzyme monolayer- and bilayer-modified electrodes: the transient response. Anal. Chem. 64:1992;630-635.
    • (1992) Anal. Chem. , vol.64 , pp. 630-635
    • Tatsuma, T.1    Watanabe, T.2    Okawa, Y.3
  • 25
    • 0027595776 scopus 로고
    • Achievement of direct electron transfer between glucose oxidase and an electrode by adsorption of hydroquinonesulfate on the enzyme
    • Yoneyama H., Kajiya Y. Achievement of direct electron transfer between glucose oxidase and an electrode by adsorption of hydroquinonesulfate on the enzyme. Sens. Actuators B. 13 14:1993;65-67.
    • (1993) Sens. Actuators B , vol.13-14 , pp. 65-67
    • Yoneyama, H.1    Kajiya, Y.2
  • 28
    • 0016378041 scopus 로고
    • Proton balance in conversions between five oxidation-reduction states of horseradish peroxidase
    • Yamada H., Yamazaki I. Proton balance in conversions between five oxidation-reduction states of horseradish peroxidase. Arch. Biochem. Biophys. 165:1974;728-738.
    • (1974) Arch. Biochem. Biophys. , vol.165 , pp. 728-738
    • Yamada, H.1    Yamazaki, I.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.