메뉴 건너뛰기




Volumn 33, Issue 2, 1999, Pages 395-402

A randomized trial comparing the impact of a nonionic (iomeprol) versus an ionic (ioxaglate) low osmolar contrast medium on abrupt vessel closure and ischemic complications after coronary angioplasty

Author keywords

[No Author keywords available]

Indexed keywords

ACETYLSALICYLIC ACID; HEPARIN; IMERON 350; IOMEPROL; IONIC CONTRAST MEDIUM; IOXAGLIC ACID; MEGLUMINE IOXAGLATE PLUS SODIUM IOXAGLATE; NONIONIC CONTRAST MEDIUM; UNCLASSIFIED DRUG;

EID: 0033081617     PISSN: 07351097     EISSN: None     Source Type: Journal    
DOI: 10.1016/S0735-1097(98)00600-7     Document Type: Article
Times cited : (47)

References (26)
  • 1
    • 0022648357 scopus 로고
    • Effect of various contrast media on coagulation, fibrinolysis, and platelet function: An in vitro and in vivo study
    • Stormoken H., Skalpe I.O., Testart M.C. Effect of various contrast media on coagulation, fibrinolysis, and platelet function an in vitro and in vivo study. Invest Radiol. 21:1986;348-354.
    • (1986) Invest Radiol , vol.21 , pp. 348-354
    • Stormoken, H.1    Skalpe, I.O.2    Testart, M.C.3
  • 4
    • 0025796950 scopus 로고
    • Anticoagulant effect of nonionic versus ionic contrast media in angiographic syringes
    • Grabowski E.F., Kaplan K., Halpern E.F. Anticoagulant effect of nonionic versus ionic contrast media in angiographic syringes. Invest Radiol. 26:1991;417-421.
    • (1991) Invest Radiol , vol.26 , pp. 417-421
    • Grabowski, E.F.1    Kaplan, K.2    Halpern, E.F.3
  • 5
    • 0027429941 scopus 로고
    • Profound platelet degranulation is an important side effect of some types of contrast media used in intreventional cardiology
    • Chronos N.A.F., Goodall A.H., Wilson D.J., Sigwart S., Buller N.P. Profound platelet degranulation is an important side effect of some types of contrast media used in intreventional cardiology. Circulation. 88:1993;2035-2044.
    • (1993) Circulation , vol.88 , pp. 2035-2044
    • Chronos, N.A.F.1    Goodall, A.H.2    Wilson, D.J.3    Sigwart, S.4    Buller, N.P.5
  • 6
    • 0027893123 scopus 로고
    • Nonionic contrast media: Procoagulants or clotting innocents?
    • Grabowski E.F., Head C., Michelson A.D. Nonionic contrast media procoagulants or clotting innocents? Invest Radiol. 28:(Suppl 5):1993;21-24.
    • (1993) Invest Radiol , vol.28 , Issue.SUPPL. 5 , pp. 21-24
    • Grabowski, E.F.1    Head, C.2    Michelson, A.D.3
  • 7
    • 0027500283 scopus 로고
    • Ionic contrast agent mediated endothelial injury causes increased platelet deposition to vascular surfaces
    • Riemann C.D., Massey C.V., McCarron D.L., Borkowski P., Johnson P.C., Ziskind A.A. Ionic contrast agent mediated endothelial injury causes increased platelet deposition to vascular surfaces. Am Heart J. 125:1993;71-78.
    • (1993) Am Heart J , vol.125 , pp. 71-78
    • Riemann, C.D.1    Massey, C.V.2    McCarron, D.L.3    Borkowski, P.4    Johnson, P.C.5    Ziskind, A.A.6
  • 8
    • 0000482774 scopus 로고
    • In vitro influence of ionic and non-ionic contrast media on thrombelestography and thrombocyte function
    • (Abstr)
    • Lindhoff-Last E., Tholouli E., Schräder R., Mosch G., Breddin H.K. In vitro influence of ionic and non-ionic contrast media on thrombelestography and thrombocyte function. Ann Hematol. 68:(Suppl II):1994;119. (Abstr).
    • (1994) Ann Hematol , vol.68 , Issue.SUPPL. II , pp. 119
    • Lindhoff-Last, E.1    Tholouli, E.2    Schräder, R.3    Mosch, G.4    Breddin, H.K.5
  • 9
    • 0023101642 scopus 로고
    • Blood clot formation in angiographic syringes containing non-ionic contrast media
    • Robertson H.J.F. Blood clot formation in angiographic syringes containing non-ionic contrast media. Radiology. 162:1987;621-622.
    • (1987) Radiology , vol.162 , pp. 621-622
    • Robertson, H.J.F.1
  • 10
    • 0023912095 scopus 로고
    • Thromboembolic complications in coronary angiography associated with the use of nonionic contrast medium
    • Grollman J.H. Jr, Liu C.K., Astone R.A., Lurie M.D. Thromboembolic complications in coronary angiography associated with the use of nonionic contrast medium. Cathet Cardiovasc Diagn. 14:1988;159-164.
    • (1988) Cathet Cardiovasc Diagn , vol.14 , pp. 159-164
    • Grollman J.H., Jr.1    Liu, C.K.2    Astone, R.A.3    Lurie, M.D.4
  • 12
    • 0026334846 scopus 로고
    • Effects of nonionic versus ionic contrast media on complications of percutaneous transluminal coronary angioplasty
    • Lembo N.J., King S.B. III, Roubin G.S., Black A.J., Douglas J.S. Jr. Effects of nonionic versus ionic contrast media on complications of percutaneous transluminal coronary angioplasty. Am J Cardiol. 67:1991;1046-1050.
    • (1991) Am J Cardiol , vol.67 , pp. 1046-1050
    • Lembo, N.J.1    King S.B. III2    Roubin, G.S.3    Black, A.J.4    Douglas J.S., Jr.5
  • 13
    • 0026009739 scopus 로고
    • Risk of thrombosis during coronary angioplasty with low osmolality contrast media
    • Esplugas E., Cequier A., Jara F., Mauri J., Soler T., Sala J., Sabate X. Risk of thrombosis during coronary angioplasty with low osmolality contrast media. Am J Cardiol. 68:1991;1020-1024.
    • (1991) Am J Cardiol , vol.68 , pp. 1020-1024
    • Esplugas, E.1    Cequier, A.2    Jara, F.3    Mauri, J.4    Soler, T.5    Sala, J.6    Sabate, X.7
  • 15
    • 0028382410 scopus 로고
    • Comparison by scanning electron microscopy of the antithrombotic potential of two low osmolality iodine contrast media during percutaneous coronary angioplasty
    • Lefevre T., Bernard A., Bertrand M., et al. Comparison by scanning electron microscopy of the antithrombotic potential of two low osmolality iodine contrast media during percutaneous coronary angioplasty. Arch Mal Coeur. 87:1994;225-233.
    • (1994) Arch Mal Coeur , vol.87 , pp. 225-233
    • Lefevre, T.1    Bernard, A.2    Bertrand, M.3
  • 16
    • 0029885644 scopus 로고    scopus 로고
    • A randomized trial of low osmolar ionic versus nonionic contrast media in patients with myocardial infarction or unstable angina undergoing percutaneous transluminal coronary angioplasty
    • Grines C.L., Schreiber T.L., Savas V., et al. A randomized trial of low osmolar ionic versus nonionic contrast media in patients with myocardial infarction or unstable angina undergoing percutaneous transluminal coronary angioplasty. J Am Coll Cardiol. 27:1996;1381-1386.
    • (1996) J Am Coll Cardiol , vol.27 , pp. 1381-1386
    • Grines, C.L.1    Schreiber, T.L.2    Savas, V.3
  • 17
    • 0031572172 scopus 로고    scopus 로고
    • Percutaneous coronary angioscopic comparison of thrombus formation during percutaneous coronary angioplasty with ionic and nonionic low osmolality contrast media in unstable angina
    • Qureshi N.R., den Heijer P., Crijns H.J.G.M. Percutaneous coronary angioscopic comparison of thrombus formation during percutaneous coronary angioplasty with ionic and nonionic low osmolality contrast media in unstable angina. Am J Cardiol. 80:1997;700-704.
    • (1997) Am J Cardiol , vol.80 , pp. 700-704
    • Qureshi, N.R.1    Den Heijer, P.2    Crijns, H.J.G.M.3
  • 18
    • 0025542168 scopus 로고
    • Coronary morphologic and clinical determinants of procedural outcome with angioplasty for multivessel disease. Implications for patient selection
    • Ellis S.G., Vandormael M.G., Cowley M.J., et al. Coronary morphologic and clinical determinants of procedural outcome with angioplasty for multivessel disease. Implications for patient selection. Circulation. 82:1990;1193-1202.
    • (1990) Circulation , vol.82 , pp. 1193-1202
    • Ellis, S.G.1    Vandormael, M.G.2    Cowley, M.J.3
  • 19
    • 0018760094 scopus 로고
    • Non-operative dilatation of coronary artery stenosis: Percutaneous transluminal coronary angioplasty
    • Grüntzig A.R., Senning A., Siegenthaler W.E. Non-operative dilatation of coronary artery stenosis Percutaneous transluminal coronary angioplasty. N Engl J Med. 301:1979;61-68.
    • (1979) N Engl J Med , vol.301 , pp. 61-68
    • Grüntzig, A.R.1    Senning, A.2    Siegenthaler, W.E.3
  • 20
    • 0023830815 scopus 로고
    • Percutaneous transluminal coronary angioplasty in 1985-86 and 1977-81. The National Heart, Lung and Blood Institute Registry
    • Detre K., Holubkov R., Kelsey S., et al. Percutaneous transluminal coronary angioplasty in 1985-86 and 1977-81. The National Heart, Lung and Blood Institute Registry. N Engl J Med. 318:1988;265-272.
    • (1988) N Engl J Med , vol.318 , pp. 265-272
    • Detre, K.1    Holubkov, R.2    Kelsey, S.3
  • 21
    • 0026548265 scopus 로고
    • Abrupt vessel closure complicating coronary angioplasty: Clinical, angiographic and therapeutic profile
    • Lincoff A.M., Popma J.J., Ellis S.G., Hacker J.A., Topol E.J. Abrupt vessel closure complicating coronary angioplasty Clinical, angiographic and therapeutic profile. J Am Coll Cardiol. 19:1992;926-932.
    • (1992) J Am Coll Cardiol , vol.19 , pp. 926-932
    • Lincoff, A.M.1    Popma, J.J.2    Ellis, S.G.3    Hacker, J.A.4    Topol, E.J.5
  • 22
    • 1842369101 scopus 로고    scopus 로고
    • GP IIb/IIIa receptor blockade and low-dose heparin during percutaneous coronary revascularization
    • EPILOG Investigators. GP IIb/IIIa receptor blockade and low-dose heparin during percutaneous coronary revascularization. N Engl J Med. 336:1997;1689-1696.
    • (1997) N Engl J Med , vol.336 , pp. 1689-1696
  • 23
    • 0023929007 scopus 로고
    • Predictors, therapeutic options, and long-term outcome of abrupt reclosure
    • Sinclair I.N., McCabe C.H., Sipperly M.E., Baim D.S. Predictors, therapeutic options, and long-term outcome of abrupt reclosure. Am J Cardiol. 61:1988;61G.
    • (1988) Am J Cardiol , vol.61
    • Sinclair, I.N.1    McCabe, C.H.2    Sipperly, M.E.3    Baim, D.S.4
  • 24
    • 0022006765 scopus 로고
    • Intracoronary thrombus: Role in coronary occlusion complicating percutaneous transluminal coronary angioplasty
    • Mabin T.A., Holmes D.R., Smith H.C., et al. Intracoronary thrombus role in coronary occlusion complicating percutaneous transluminal coronary angioplasty. J Am Coll Cardiol. 5:1985;198-203.
    • (1985) J Am Coll Cardiol , vol.5 , pp. 198-203
    • Mabin, T.A.1    Holmes, D.R.2    Smith, H.C.3
  • 25
    • 0001211528 scopus 로고    scopus 로고
    • Impact of contrast media on clinical outcomes following percutaneous coronary interventions with platalet glycoprotein IIb/IIIa inhibition: Meta-analysis of clinical trials with Abciximab
    • (Abstr)
    • Aguirre F.V., Simoons M.L., Ferguson J.J., FitzPatrick S.E., Anderson K.M., Kern M.J., Tcheng J.E. Impact of contrast media on clinical outcomes following percutaneous coronary interventions with platalet glycoprotein IIb/IIIa inhibition meta-analysis of clinical trials with Abciximab. Circulation. 96:(Suppl 1):1997;161. (Abstr).
    • (1997) Circulation , vol.96 , Issue.SUPPL. 1 , pp. 161
    • Aguirre, F.V.1    Simoons, M.L.2    Ferguson, J.J.3    FitzPatrick, S.E.4    Anderson, K.M.5    Kern, M.J.6    Tcheng, J.E.7
  • 26
    • 0029911292 scopus 로고    scopus 로고
    • The potential thrombogenic action of a nonionic radiographic contrast medium used during coronary angiography is offset by heparin during coronary angioplasty
    • Mukherjee M., Scully M.F., Thomas M., Jewitt D., Kakkar V.V. The potential thrombogenic action of a nonionic radiographic contrast medium used during coronary angiography is offset by heparin during coronary angioplasty. Thrombos Hemostas. 76:1996;679-681.
    • (1996) Thrombos Hemostas , vol.76 , pp. 679-681
    • Mukherjee, M.1    Scully, M.F.2    Thomas, M.3    Jewitt, D.4    Kakkar, V.V.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.