메뉴 건너뛰기




Volumn 6, Issue 1, 1999, Pages 43-50

PD characteristics and mechanisms in artificial air-filled voids at room and liquid nitrogen temperatures

Author keywords

[No Author keywords available]

Indexed keywords

AIR; CONDENSATION; ELECTRIC BREAKDOWN OF GASES; ELECTRIC CURRENTS; GLOW DISCHARGES; LOW TEMPERATURE PHENOMENA; OXYGEN; PARTIAL DISCHARGES;

EID: 0033076077     PISSN: 10709878     EISSN: None     Source Type: Journal    
DOI: 10.1109/94.752008     Document Type: Article
Times cited : (9)

References (18)
  • 4
    • 0026821306 scopus 로고
    • The Importance of Statistical Characteristics of Partial Discharge Data
    • B. Eruth and L. Niemeyer, "The Importance of Statistical Characteristics of Partial Discharge Data", IEEE Trans. on EI, Vol. 27, pp. 60-69, 1992.
    • (1992) IEEE Trans. on EI , vol.27 , pp. 60-69
    • Eruth, B.1    Niemeyer, L.2
  • 5
    • 33747920906 scopus 로고
    • Partial Discharge Properties in a Spherical Void
    • T. Moriuchi and M. Tan, "Partial Discharge Properties in a Spherical Void", Trans. of IEEJ, Part A, Vol. 104, pp. 629-634, 1984.
    • (1984) Trans. of IEEJ, Part A , vol.104 , pp. 629-634
    • Moriuchi, T.1    Tan, M.2
  • 8
    • 0022898877 scopus 로고
    • Internal Partial Discharge and Material Degradaation
    • T. Tanaka, "Internal Partial Discharge and Material Degradaation", IEEE Trans. on EI, Vol. 21 No. 6, pp. 899-905, 1986.
    • (1986) IEEE Trans. on EI , vol.21 , Issue.6 , pp. 899-905
    • Tanaka, T.1
  • 9
    • 0025546236 scopus 로고
    • Transition from streamer to Townsend mechanisms in dielectric voids
    • P. Morshuis and F. H. Kreuger, "Transition from streamer to Townsend mechanisms in dielectric voids", J. Phys. Vol. D23, pp. 1562-1568, 1990.
    • (1990) J. Phys. , vol.D23 , pp. 1562-1568
    • Morshuis, P.1    Kreuger, F.H.2
  • 10
    • 0027540045 scopus 로고
    • Spark-to-glow Discharge Transition due to Increased Surface Conductivity on Epoxy Resin Specimens
    • C. Hudon, R. Bartinikas and M. R. Wertheimer, "Spark-to-glow Discharge Transition due to Increased Surface Conductivity on Epoxy Resin Specimens", IEEE Trans. on Electrical Insulation, Vol. 28, No. 1, pp. 1-8, 1993.
    • (1993) IEEE Trans. on Electrical Insulation , vol.28 , Issue.1 , pp. 1-8
    • Hudon, C.1    Bartinikas, R.2    Wertheimer, M.R.3
  • 11
    • 0027836050 scopus 로고
    • On the Character of Different Forms of Partial Discharge and their Related Terminologies
    • R. Bartnikas and J. P. Novak, "On the Character of Different Forms of Partial Discharge and their Related Terminologies", IEEE Trans. on Electrical Insulation, Vol. 28, No. 6, pp. 956-968, 1993.
    • (1993) IEEE Trans. on Electrical Insulation , vol.28 , Issue.6 , pp. 956-968
    • Bartnikas, R.1    Novak, J.P.2
  • 12
    • 0021503419 scopus 로고
    • The Physics of Partial Discharges in Solid Dielectrics
    • J. C. Devins, "The Physics of Partial Discharges in Solid Dielectrics", IEEE Trans. on Electrical Insulation, Vol. 19, No. 5, pp. 475-494, 1984.
    • (1984) IEEE Trans. on Electrical Insulation , vol.19 , Issue.5 , pp. 475-494
    • Devins, J.C.1
  • 13
    • 0029387931 scopus 로고
    • Assessment of Dielectric Degradation by Ultrawide-band PD Detection
    • P. Morshuis, "Assessment of Dielectric Degradation by Ultrawide-band PD Detection", IEEE Trans. on Dielectrics and Electrical Insulation, Vol. 2, No. 5, pp. 744-760, 1995.
    • (1995) IEEE Trans. on Dielectrics and Electrical Insulation , vol.2 , Issue.5 , pp. 744-760
    • Morshuis, P.1
  • 16
    • 0025438150 scopus 로고
    • Measurement of Partial Discharge by Computer and Analysis of Partial Discharge Distribution by Monte Carlo Method
    • M. Hikita, A. Nakamura, T. Mizutani and M. Ieda, "Measurement of Partial Discharge by Computer and Analysis of Partial Discharge Distribution by Monte Carlo Method", IEEE Trans. on Electrical Insulation, Vol. 25, pp. 453-468, 1990.
    • (1990) IEEE Trans. on Electrical Insulation , vol.25 , pp. 453-468
    • Hikita, M.1    Nakamura, A.2    Mizutani, T.3    Ieda, M.4
  • 17


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.