메뉴 건너뛰기




Volumn 69, Issue 1, 1999, Pages 49-57

3-D experimental identification of force systems from orthodontic loops activated for first order corrections

Author keywords

First order correction; Force system; Loops; Wires

Indexed keywords

BETA TITANIUM; DENTAL ALLOY; STAINLESS STEEL; TITANIUM;

EID: 0033069827     PISSN: 00033219     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (31)

References (29)
  • 1
    • 0019532176 scopus 로고
    • Functional occlusion for the orthodontist
    • Roth RH. Functional occlusion for the orthodontist. J Clin Orthod 1981;15(1)32-40:44-51.
    • (1981) J Clin Orthod , vol.15 , Issue.1 , pp. 32-40
    • Roth, R.H.1
  • 2
    • 0016932795 scopus 로고
    • Straight wire: The concept and appliance explained and compared
    • Andrews LF. Straight wire: The concept and appliance explained and compared. J Clin Orthod 1976;10:174-195.
    • (1976) J Clin Orthod , vol.10 , pp. 174-195
    • Andrews, L.F.1
  • 3
    • 0022081020 scopus 로고
    • Chinese Ni-Ti wire. A new orthodontic alloy
    • Burstone CJ, Qin B, Morton JY. Chinese Ni-Ti wire. A new orthodontic alloy. Am J Orthod 1985;87:445-452.
    • (1985) Am J Orthod , vol.87 , pp. 445-452
    • Burstone, C.J.1    Qin, B.2    Morton, J.Y.3
  • 4
    • 0022747571 scopus 로고
    • The superelastic properties of Japanese Ni-Ti alloy for use in orthodontics
    • Miura F, Mogi M, Ohura Y, Hamanaka H. The superelastic properties of Japanese Ni-Ti alloy for use in orthodontics. Am J Orthod Dentofac Orthop 1986;90:1-10.
    • (1986) Am J Orthod Dentofac Orthop , vol.90 , pp. 1-10
    • Miura, F.1    Mogi, M.2    Ohura, Y.3    Hamanaka, H.4
  • 5
    • 0025494752 scopus 로고
    • New Application of superelastic NiTi rectangular wire
    • Miura F, Mogi M, Okamoto Y. New Application of superelastic NiTi rectangular wire. J Clin Orthod 1990;24:544-548.
    • (1990) J Clin Orthod , vol.24 , pp. 544-548
    • Miura, F.1    Mogi, M.2    Okamoto, Y.3
  • 6
    • 85181025793 scopus 로고
    • Variable transformation temperature orthodontics. Copper Ni-Ti makes it a reality
    • Sachdeva R. Variable transformation temperature orthodontics. Copper Ni-Ti makes it a reality. Clinical Impressions 1994;3(1):2-5.
    • (1994) Clinical Impressions , vol.3 , Issue.1 , pp. 2-5
    • Sachdeva, R.1
  • 7
    • 85180977759 scopus 로고    scopus 로고
    • Changes in 2nd and 3rd order tooth position in straight wire appliances related to variation in vertical bracket positioning
    • In press
    • Miethke RR, Melsen B. Changes in 2nd and 3rd order tooth position in straight wire appliances related to variation in vertical bracket positioning. Am J Orthod Dentofac Orthop, In press, 1997.
    • (1997) Am J Orthod Dentofac Orthop
    • Miethke, R.R.1    Melsen, B.2
  • 9
    • 0006642501 scopus 로고
    • The biomechanical rationale of orthodontic therapy
    • Melsen B, ed. Current controversies in orthodontics
    • Burstone CJ. The biomechanical rationale of orthodontic therapy. In: Melsen B, ed. Current controversies in orthodontics. Quintessence 1991:131-146.
    • (1991) Quintessence , pp. 131-146
    • Burstone, C.J.1
  • 10
    • 0021464910 scopus 로고
    • Variability in three morphologic features of the permanent maxillary central incisor
    • Bryant RM, Sadowsky PL, Hazelrig JB. Variability in three morphologic features of the permanent maxillary central incisor. Am J Orthod 1984;86:25-32.
    • (1984) Am J Orthod , vol.86 , pp. 25-32
    • Bryant, R.M.1    Sadowsky, P.L.2    Hazelrig, J.B.3
  • 12
  • 13
    • 0023675051 scopus 로고
    • Creative wire bending: The force system from step and V bends
    • Burstone CJ, Koenig HA. Creative wire bending: The force system from step and V bends. Am J Orthod Dentofac Orthop 1988;93:59-67.
    • (1988) Am J Orthod Dentofac Orthop , vol.93 , pp. 59-67
    • Burstone, C.J.1    Koenig, H.A.2
  • 15
    • 0019079855 scopus 로고
    • Force systems from orthodontic appliances: An analytical and experimental comparison
    • Koenig HA, Vanderby R, Solonche DJ, Burstone CJ. Force systems from orthodontic appliances: An analytical and experimental comparison. J Biomech Eng 1980;102:294-300.
    • (1980) J Biomech Eng , vol.102 , pp. 294-300
    • Koenig, H.A.1    Vanderby, R.2    Solonche, D.J.3    Burstone, C.J.4
  • 16
    • 0017049116 scopus 로고
    • Three-dimensional large displacement analysis of orthodontic appliances
    • De Franco J, Koenig HA, Burstone CJ. Three-dimensional large displacement analysis of orthodontic appliances. J Biomech 1976;9:793:801.
    • (1976) J Biomech , vol.9 , pp. 793
    • De Franco, J.1    Koenig, H.A.2    Burstone, C.J.3
  • 17
    • 0017718005 scopus 로고
    • Experimentally determined force systems from vertically activated orthodontic loops
    • Vanderby RJ, Burstone CJ, Solondre DJ, Ratches JA. Experimentally determined force systems from vertically activated orthodontic loops. Angle Orthod 1977;47:272-279.
    • (1977) Angle Orthod , vol.47 , pp. 272-279
    • Vanderby, R.J.1    Burstone, C.J.2    Solondre, D.J.3    Ratches, J.A.4
  • 18
    • 0024594141 scopus 로고
    • Force systems from an ideal arch-long deflection considerations
    • Koenig HA, Burstone CJ. Force systems from an ideal arch-long deflection considerations. Angle Orthod 1989;59:11-16.
    • (1989) Angle Orthod , vol.59 , pp. 11-16
    • Koenig, H.A.1    Burstone, C.J.2
  • 19
    • 0016980566 scopus 로고
    • The mechanics of plain and looped arches. Part II
    • Waters NE. The mechanics of plain and looped arches. Part II. Br J Orthod 1976;3:161-167.
    • (1976) Br J Orthod , vol.3 , pp. 161-167
    • Waters, N.E.1
  • 20
    • 0024152092 scopus 로고
    • An experimental investigation into the effect of dimensional changes on the stiffness of double vertical incisor alignment loop
    • Brown ID. An experimental investigation into the effect of dimensional changes on the stiffness of double vertical incisor alignment loop. Eur J Orthod 1988;10:319-328.
    • (1988) Eur J Orthod , vol.10 , pp. 319-328
    • Brown, I.D.1
  • 21
    • 0023372280 scopus 로고
    • The mechanics of looped arches with non-parallel or angulated legs
    • Waters NE, Ward PJ. The mechanics of looped arches with non-parallel or angulated legs. Br J Orthod 1987;14:61-67.
    • (1987) Br J Orthod , vol.14 , pp. 61-67
    • Waters, N.E.1    Ward, P.J.2
  • 22
    • 0024060251 scopus 로고
    • The behaviour of multiple loops in torsion
    • Cavina RA, Waters NE. The behaviour of multiple loops in torsion. Br J Orthod 1988;15:149-156.
    • (1988) Br J Orthod , vol.15 , pp. 149-156
    • Cavina, R.A.1    Waters, N.E.2
  • 23
    • 0018344605 scopus 로고
    • An evaluation of beta-titanium alloys for use in orthodontic appliances
    • Goldberg AJ, Burstone CJ. An evaluation of beta-titanium alloys for use in orthodontic appliances. J Dent Res 1979;58:593-600.
    • (1979) J Dent Res , vol.58 , pp. 593-600
    • Goldberg, A.J.1    Burstone, C.J.2
  • 24
    • 0026665008 scopus 로고
    • A miniaturized force-torque sensor with six degrees of freedom for dental measurements
    • Planert J. A miniaturized force-torque sensor with six degrees of freedom for dental measurements. Clinical Physics and Physiology Measurements 1992;13:241-248.
    • (1992) Clinical Physics and Physiology Measurements , vol.13 , pp. 241-248
    • Planert, J.1
  • 25
    • 0026904676 scopus 로고
    • In vitro Studie zur Anwendung von Palatinal Bogen bei der Kontrolle der Positione oberer Molaren
    • Jäger A, Planert J, Modler H, Gripp L. In vitro Studie zur Anwendung von Palatinal Bogen bei der Kontrolle der Positione oberer Molaren. Fortschr Kieferorthop 1992;53:230-238.
    • (1992) Fortschr Kieferorthop , vol.53 , pp. 230-238
    • Jäger, A.1    Planert, J.2    Modler, H.3    Gripp, L.4
  • 27
    • 0018831556 scopus 로고
    • Beta titanium: A new orthodontic alloy
    • Burstone CJ, Goldberg AJ. Beta titanium: A new orthodontic alloy. Am J Orthod 1980;77:121-132.
    • (1980) Am J Orthod , vol.77 , pp. 121-132
    • Burstone, C.J.1    Goldberg, A.J.2
  • 28
    • 0020754885 scopus 로고
    • On the use of nomograms to determine the elastic properties ratios of orthodontic archwire materials
    • Kusy RP. On the use of nomograms to determine the elastic properties ratios of orthodontic archwire materials. Am J Orthod 1983;83:374-381.
    • (1983) Am J Orthod , vol.83 , pp. 374-381
    • Kusy, R.P.1
  • 29
    • 0020841611 scopus 로고
    • The influence of drawing parameters on the mechanical properties of two beta titanium alloys
    • Shastry CV, Goldberg AJ. The influence of drawing parameters on the mechanical properties of two beta titanium alloys. J Dent Res 1983;62:1092-1097.
    • (1983) J Dent Res , vol.62 , pp. 1092-1097
    • Shastry, C.V.1    Goldberg, A.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.