메뉴 건너뛰기




Volumn 9, Issue 6, 1999, Pages 847-852

A novel object-independent 'balanced' reference scan for echo-planar imaging

Author keywords

EPI; MRI; Reconstruction; Reference scans

Indexed keywords

ALGORITHM; ANISOTROPY; ARTICLE; IMAGE PROCESSING; NUCLEAR MAGNETIC RESONANCE IMAGING; PRIORITY JOURNAL; PROTON NUCLEAR MAGNETIC RESONANCE;

EID: 0033065598     PISSN: 10531807     EISSN: None     Source Type: Journal    
DOI: 10.1002/(SICI)1522-2586(199906)9:6<847::AID-JMRI13>3.0.CO;2-D     Document Type: Article
Times cited : (29)

References (14)
  • 1
    • 0026601923 scopus 로고
    • Image reconstruction for echo planar imaging with non-equidistant k-space sampling
    • Bruder H. Fischer H, Reinfelder HE, Schmitt F. Image reconstruction for echo planar imaging with non-equidistant k-space sampling. Magn Reson Med 1992;23:311-323.
    • (1992) Magn Reson Med , vol.23 , pp. 311-323
    • Bruder, H.1    Fischer, H.2    Reinfelder, H.E.3    Schmitt, F.4
  • 2
    • 0030924013 scopus 로고    scopus 로고
    • Quantification and reduction of ghosting artifacts in interleaved echo planar imaging
    • Reeder SB, Atalar E, Bolster BD, McVeigh ER. Quantification and reduction of ghosting artifacts in interleaved echo planar imaging. Magn Reson Med 1997;38:429-439.
    • (1997) Magn Reson Med , vol.38 , pp. 429-439
    • Reeder, S.B.1    Atalar, E.2    Bolster, B.D.3    McVeigh, E.R.4
  • 3
    • 0025783488 scopus 로고
    • GRASE (gradient- and spin-echo) imaging: A novel fast MRI technique
    • Oshio K, Feinberg DA. GRASE (gradient- and spin-echo) imaging: a novel fast MRI technique. Magn Reson Med 1991;20:344-349.
    • (1991) Magn Reson Med , vol.20 , pp. 344-349
    • Oshio, K.1    Feinberg, D.A.2
  • 6
    • 0025977678 scopus 로고
    • Analysis of eddy currents in nuclear magnetic resonance imaging
    • Ahn CB, Cho ZH. Analysis of eddy currents in nuclear magnetic resonance imaging. Magn Reson Med 1991;17:149-163.
    • (1991) Magn Reson Med , vol.17 , pp. 149-163
    • Ahn, C.B.1    Cho, Z.H.2
  • 9
    • 0028145655 scopus 로고
    • Phase errors in multi-shot echo planar imaging
    • Feinberg DA, Oshio K. Phase errors in multi-shot echo planar imaging. Magn Reson Med 1994;32:535-539.
    • (1994) Magn Reson Med , vol.32 , pp. 535-539
    • Feinberg, D.A.1    Oshio, K.2
  • 10
    • 0030912558 scopus 로고    scopus 로고
    • Reduction of geometric distortion and intensity distortions in echo-planar imaging using a multireference scan
    • Wan X, Gullberg GT, Parker DL, Zeng GL. Reduction of geometric distortion and intensity distortions in echo-planar imaging using a multireference scan. Magn Reson Med 1997;37:932-944.
    • (1997) Magn Reson Med , vol.37 , pp. 932-944
    • Wan, X.1    Gullberg, G.T.2    Parker, D.L.3    Zeng, G.L.4
  • 11
    • 0021282475 scopus 로고
    • Measurement of flow with NMR imaging using a gradient pulse and phase difference technique
    • Bryant DJ, Payne JA, Firmin DN, Longmore DB. Measurement of flow with NMR imaging using a gradient pulse and phase difference technique. J Comput Assist Tomogr 1984;8:588-593.
    • (1984) J Comput Assist Tomogr , vol.8 , pp. 588-593
    • Bryant, D.J.1    Payne, J.A.2    Firmin, D.N.3    Longmore, D.B.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.