-
1
-
-
0342397658
-
Implant materials in rigid fixation
-
Altobelli D.E Implant materials in rigid fixation Yaremchuk Rigid fixation of the craniomaxillofacial skeleton 1992 Butterworth-Heinemann Boston 43
-
(1992)
, pp. 43
-
-
Altobelli, D.E1
-
2
-
-
0022053214
-
Small plate osteosynthesis of mandibular fractures
-
Cawood J.I Small plate osteosynthesis of mandibular fractures Br J Oral Maxillofac. Surg. 23 1985 77 91
-
(1985)
Br J Oral Maxillofac. Surg.
, vol.23
, pp. 77-91
-
-
Cawood, J.I1
-
3
-
-
0026277510
-
Cortical thickness in human mandibles: clinical relevance to the sagittal split ramus osteotomy
-
Carter T.B. D.E. Frost M.R. Tucker J.R. Zuniga Cortical thickness in human mandibles: clinical relevance to the sagittal split ramus osteotomy Int. J. Adult Orthognath. Surg. 6 1991 257 260
-
(1991)
Int. J. Adult Orthognath. Surg.
, vol.6
, pp. 257-260
-
-
Carter, T.B.1
Frost, D.E.2
Tucker, M.R.3
Zuniga, J.R.4
-
4
-
-
0017045214
-
Syntheses mandibulaires. Location des syntheses en fonction des contraintes mandibulaires
-
Champy M. J.P. Lodde Syntheses mandibulaires. Location des syntheses en fonction des contraintes mandibulaires Mandibular osteosynthesis. Positioning of the miniplate according to mandibular stress Rev. Stomatol. 77 1976 971 979
-
(1976)
Rev. Stomatol.
, vol.77
, pp. 971-979
-
-
Champy, M.1
Lodde, J.P.2
-
5
-
-
0013150453
-
The Strasbourg miniplate osteosynthesis
-
Champy M. H.D. Pape K.L. Gerlach J.P. Lodde The Strasbourg miniplate osteosynthesis Krüger and Schilli: Oral and maxillofacial traumatology Vol 2 1986 Quintessence Chicago 19 25
-
(1986)
, pp. 19-25
-
-
Champy, M.1
Pape, H.D.2
Gerlach, K.L.3
Lodde, J.P.4
-
6
-
-
0025200816
-
The elastic moduli of human subchondral, trabecular and cortical bone tissue and the size dependency of cortical bone modulus
-
Choi K. J.L. Kuhn M.J. Ciarelli S.A. Goldstein The elastic moduli of human subchondral, trabecular and cortical bone tissue and the size dependency of cortical bone modulus J. Biomech. 23 1990 1103 1113
-
(1990)
J. Biomech.
, vol.23
, pp. 1103-1113
-
-
Choi, K.1
Kuhn, J.L.2
Ciarelli, M.J.3
Goldstein, S.A.4
-
8
-
-
0019947037
-
A method for the study of undecalcified bones and teeth with attached soft tissues
-
Donath K. G. Breuner A method for the study of undecalcified bones and teeth with attached soft tissues J. Oral Pathol. 11 1982 318 326
-
(1982)
J. Oral Pathol.
, vol.11
, pp. 318-326
-
-
Donath, K.1
Breuner, G.2
-
9
-
-
0025966481
-
Lag screw fixation of anterior mandibular fractures
-
Ellis E. G. Ghali Lag screw fixation of anterior mandibular fractures J. Oral. Maxillofac. Surg. 49 1991 13 21
-
(1991)
J. Oral. Maxillofac. Surg.
, vol.49
, pp. 13-21
-
-
Ellis, E.1
Ghali, G.2
-
10
-
-
0026021912
-
Lag screw fixation of mandibular angle fractures
-
Ellis E. G. Ghali Lag screw fixation of mandibular angle fractures J. Oral Maxillofac. Surg. 49 1991 234 243
-
(1991)
J. Oral Maxillofac. Surg.
, vol.49
, pp. 234-243
-
-
Ellis, E.1
Ghali, G.2
-
12
-
-
0025619762
-
The effect of variation in structure on the Young's modulus of cancellous bone: a comparison of human and non-human material
-
Hodgskinson R. J.D. Currey The effect of variation in structure on the Young's modulus of cancellous bone: a comparison of human and non-human material Proc. Inst. Mech. Eng. H 204 1990 115 121
-
(1990)
, pp. 115-121
-
-
Hodgskinson, R.1
Currey, J.D.2
-
13
-
-
0026514596
-
Rigid internal fixation of mandibular fractures. An analysis of 270 fractures treated using the AO/ASIF method
-
Iizuka T. C. Lindqvist Rigid internal fixation of mandibular fractures. An analysis of 270 fractures treated using the AO/ASIF method Int. J. Oral Macillofac. Surg. 21 1992 65 69
-
(1992)
Int. J. Oral Macillofac. Surg.
, vol.21
, pp. 65-69
-
-
Iizuka, T.1
Lindqvist, C.2
-
14
-
-
0026541546
-
A comparison of two methods for inserting lag screws
-
Ilg P. E. Ellis A comparison of two methods for inserting lag screws J. Oral Maxillofac. Surg. 50 1992 119 123
-
(1992)
J. Oral Maxillofac. Surg.
, vol.50
, pp. 119-123
-
-
Ilg, P.1
Ellis, E.2
-
16
-
-
0024678978
-
Histomorphometric evaluation of stress shielding in mandibular continuity defects treated with rigid fixation plates and bone grafts
-
Kennady M.C. M.R. Tucker G.E. Lester M.J. Buckley Histomorphometric evaluation of stress shielding in mandibular continuity defects treated with rigid fixation plates and bone grafts Int. J. Oral Maxillofac. Surg. 18 1989 170 174
-
(1989)
Int. J. Oral Maxillofac. Surg.
, vol.18
, pp. 170-174
-
-
Kennady, M.C.1
Tucker, M.R.2
Lester, G.E.3
Buckley, M.J.4
-
17
-
-
0004082141
-
Biomechanics and osteosynthesis of condylar neck fractures of the mandible
-
Krenkel C Biomechanics and osteosynthesis of condylar neck fractures of the mandible 1994 Quintessence Carol Stream 47 53
-
(1994)
, pp. 47-53
-
-
Krenkel, C1
-
18
-
-
0014312127
-
Zur stabilen Osteosynthese bei Unterkieferfrakturen
-
Luhr H.G. Zur stabilen Osteosynthese bei Unterkieferfrakturen Stable Osteosynthesis of mandibular fractures Dtsch. Zahnarztl. Z. 23 1968 754
-
(1968)
Dtsch. Zahnarztl. Z.
, vol.23
, pp. 754
-
-
Luhr, H.G.1
-
19
-
-
85119794138
-
Compression plate osteosynthesis through the Luhr system
-
Luhr H.G Compression plate osteosynthesis through the Luhr system Krüger and Schilli: Oral and maxillofacial traumatology Vol 1 1986 Quintessence Chicago 319 327
-
(1986)
, pp. 319-327
-
-
Luhr, H.G1
-
20
-
-
0031170947
-
The effects of density and test conditions on measured compression and shear strength of cancellous bone from the lumbar vertebrae of ewes
-
Mitton D. C. Rumelhart D. Hans P.J. Meunier The effects of density and test conditions on measured compression and shear strength of cancellous bone from the lumbar vertebrae of ewes Med. Eng. Phys. 19 1997 464 474
-
(1997)
Med. Eng. Phys.
, vol.19
, pp. 464-474
-
-
Mitton, D.1
Rumelhart, C.2
Hans, D.3
Meunier, P.J.4
-
21
-
-
0023629512
-
Solitary lag screw osteosynthesis in the treatment of mandibular angle fractures
-
Niederdellmann H. V. Shetty Solitary lag screw osteosynthesis in the treatment of mandibular angle fractures Plast. Reconstr. Surg. 80 1987 68 74
-
(1987)
Plast. Reconstr. Surg.
, vol.80
, pp. 68-74
-
-
Niederdellmann, H.1
Shetty, V.2
-
22
-
-
0018762030
-
Physical and biological aspects of fracture healing with special reference to internal fixation
-
Perren S Physical and biological aspects of fracture healing with special reference to internal fixation Clin. Orthop. 138 1979 175 196
-
(1979)
Clin. Orthop.
, vol.138
, pp. 175-196
-
-
Perren, S1
-
23
-
-
0024565314
-
Comparison of compression and torque measurements of self tapping and pretapped screws
-
Phillips J.H. B.A. Rahn Comparison of compression and torque measurements of self tapping and pretapped screws Plast. Reconstr. Surg. 83 1989 447 456
-
(1989)
Plast. Reconstr. Surg.
, vol.83
, pp. 447-456
-
-
Phillips, J.H.1
Rahn, B.A.2
-
24
-
-
0026737733
-
Biomechanical validation of the solitary lag screw technique for reducing mandibular angle fractures
-
Shetty V. A. Caputo Biomechanical validation of the solitary lag screw technique for reducing mandibular angle fractures J. Oral Maxillofac. Surg. 50 1992 603 607
-
(1992)
J. Oral Maxillofac. Surg.
, vol.50
, pp. 603-607
-
-
Shetty, V.1
Caputo, A.2
-
25
-
-
0029003960
-
Fracture line stability as a function of the internal fixation system: an in vitro comparison using a mandibular angle fracture model
-
Shetty V. D. Mc Brearty M. Fourney A. Caputo Fracture line stability as a function of the internal fixation system: an in vitro comparison using a mandibular angle fracture model J. Oral Maxillofac. Surg. 53 1995 791 801
-
(1995)
J. Oral Maxillofac. Surg.
, vol.53
, pp. 791-801
-
-
Shetty, V.1
Mc Brearty, D.2
Fourney, M.3
Caputo, A.4
-
26
-
-
0015694102
-
Mechanical factors influencing the holding power of screws in compact bone
-
Uhthoff H.K Mechanical factors influencing the holding power of screws in compact bone J. Bone Joint Surg. 55B 1973 633 639
-
(1973)
J. Bone Joint Surg.
, vol.55B
, pp. 633-639
-
-
Uhthoff, H.K1
-
27
-
-
0027935775
-
Retrospective analysis of 279 patients with isolated mandibular fractures treated with titanium miniplates
-
Tuovinen V. S.E. Norholt S. Sindet-Pedersen J. Jensen Retrospective analysis of 279 patients with isolated mandibular fractures treated with titanium miniplates J. Oral Maxillofac. Surg. 52 1994 931 935
-
(1994)
J. Oral Maxillofac. Surg.
, vol.52
, pp. 931-935
-
-
Tuovinen, V.1
Norholt, S.E.2
Sindet-Pedersen, S.3
Jensen, J.4
|