메뉴 건너뛰기




Volumn 88, Issue 2, 1999, Pages 103-112

Is ICD-programming on double intraoperative defibrillation-threshold energy safe and effective during long-time follow-up? Results of a prospective randomized multicenter study (low energy endotak trial - LEET);Ist eine ICD-programmierung auf eine schockenergie der doppelten intraoperativen defibrillationsschwelle im langzeitverlauf sicher effektiv? Ergebnisse einer prospektiven randomisierten multizenterstudie (low energy endotak trial - LEET)

Author keywords

Defibrillation threshold; Efficacy; Energy safety margin; Implantable cardioverter defibrillator

Indexed keywords

ARTICLE; CARDIOVERSION; DEFIBRILLATION; DEFIBRILLATOR; ELECTROSTIMULATION THERAPY; FOLLOW UP; HEART LEFT VENTRICLE FUNCTION; HEART VENTRICLE FIBRILLATION; HUMAN; IMPLANTATION; SAFETY; SUDDEN DEATH; TREATMENT OUTCOME;

EID: 0033060094     PISSN: 03005860     EISSN: None     Source Type: Journal    
DOI: 10.1007/s003920050266     Document Type: Article
Times cited : (2)

References (34)
  • 1
    • 0027269887 scopus 로고
    • Implantable cardioverter/defibrillator for prevention of sudden cardiac death in patients with ventricular tachycardia and ventricular fibrillation
    • Akahar M, Jazayeri M, Sra J, Tehou P, Rovang K, Blank Z, Dhala A, Deshpande S, Axtell K (1993) Implantable cardioverter/defibrillator for prevention of sudden cardiac death in patients with ventricular tachycardia and ventricular fibrillation. PACE 16:511-518
    • (1993) PACE , vol.16 , pp. 511-518
    • Akahar, M.1    Jazayeri, M.2    Sra, J.3    Tehou, P.4    Rovang, K.5    Blank, Z.6    Dhala, A.7    Deshpande, S.8    Axtell, K.9
  • 3
    • 0028577198 scopus 로고
    • Transvenous-sucutaneous defibrillation leads; effect of transvenous electrode polarity on defibrillation threshold
    • Block M, Hammel D, Böcker D, Breithard G et al (1994) Transvenous-sucutaneous defibrillation leads; effect of transvenous electrode polarity on defibrillation threshold. J of Cardiovascular Elektrophysiology 5:912-918
    • (1994) J of Cardiovascular Elektrophysiology , vol.5 , pp. 912-918
    • Block, M.1    Hammel, D.2    Böcker, D.3    Breithard, G.4
  • 6
    • 0030851245 scopus 로고    scopus 로고
    • Ergebnisse der testung der defibrillationsfunktion implantierbarer kardioverter/defibrillator
    • Brunn J, Block M, Weber M, Breithardt et al (1997) Ergebnisse der Testung der Defibrillationsfunktion implantierbarer Kardioverter/Defibrillator. Z. Kardiologie 86: 450-459
    • (1997) Z Kardiologie , vol.86 , pp. 450-459
    • Brunn, J.1    Block, M.2    Weber, M.3    Breithardt4
  • 7
    • 0023103956 scopus 로고
    • The relationship between successful defibrillation and delivered energy in open-chest dogs; reappriasal of the defibrillation threshold concept
    • Davy JM, Fain ES, Dorian P, Winkle RA (1987) The relationship between successful defibrillation and delivered energy in open-chest dogs; reappriasal of the defibrillation threshold concept. Am Heart J. 113:77-84
    • (1987) Am Heart J , vol.113 , pp. 77-84
    • Davy, J.M.1    Fain, E.S.2    Dorian, P.3    Winkle, R.A.4
  • 8
    • 0026657534 scopus 로고
    • Clinical characteristics and outcome of patients with high defibrillation threshold
    • Epstein AE, Ellenbogen KA, Kirk KA, Kay GN, Dailey SM, Plumb VJ and the high defibrillation threshold investigators (1992) Clinical characteristics and outcome of patients with high defibrillation threshold Circulation 86:1206-1216
    • (1992) Circulation , vol.86 , pp. 1206-1216
    • Epstein, A.E.1    Ellenbogen, K.A.2    Kirk, K.A.3    Kay, G.N.4    Dailey, S.M.5    Plumb, V.J.6
  • 9
    • 0026665667 scopus 로고
    • Efficacy of automatic multimodal device therapy for ventricular tachyarrhythmias as delivered by a new implantable pacing cardioverter-defibrillator; results of a European multicenter study of 102 patients
    • Frommer M, Brachman J, Block M, Siebels J, Hoffmann E, Almendral J, Ohm OJ, Den Dulk K, Coumel P, Camm AJ, Touboul P (1992) Efficacy of automatic multimodal device therapy for ventricular tachyarrhythmias as delivered by a new implantable pacing cardioverter-defibrillator; results of a European multicenter study of 102 patients. Circulation 86:363-374
    • (1992) Circulation , vol.86 , pp. 363-374
    • Frommer, M.1    Brachman, J.2    Block, M.3    Siebels, J.4    Hoffmann, E.5    Almendral, J.6    Ohm, O.J.7    Den Dulk, K.8    Coumel, P.9    Camm, A.J.10    Touboul, P.11
  • 10
    • 0023616447 scopus 로고
    • Success of chronic defibrillation and the role of antiarrhythmic drugs with the automatic implantable cardioverter/defibrillator
    • Guarnieri T, Levine JH, Veltri EP (1987) Success of chronic defibrillation and the role of antiarrhythmic drugs with the automatic implantable cardioverter/defibrillator. Am J Cardiol 60:1061
    • (1987) Am J Cardiol , vol.60 , pp. 1061
    • Guarnieri, T.1    Levine, J.H.2    Veltri, E.P.3
  • 12
    • 0028074508 scopus 로고
    • Early postoperative increase in defibrillation threshold with non thoracotomy systems in humans
    • Hsia HM, Mitra RI, Flores BT, Marchlinski (1994) Early postoperative increase in defibrillation threshold with non thoracotomy systems in humans. PACE 17:1166-1173
    • (1994) PACE , vol.17 , pp. 1166-1173
    • Hsia, H.M.1    Mitra, R.I.2    Flores, B.T.3    Marchlinski4
  • 13
    • 0023771367 scopus 로고
    • Prediction of defibrillation threshold measurement with sequential pulses and two current pathways in humans
    • Jones DL, Klein GJ, Giuraudon GM, Sharma AD, Yee R, Kallok MJ (1988) Prediction of defibrillation threshold measurement with sequential pulses and two current pathways in humans. Circulation 78:1144-1149
    • (1988) Circulation , vol.78 , pp. 1144-1149
    • Jones, D.L.1    Klein, G.J.2    Giuraudon, G.M.3    Sharma, A.D.4    Yee, R.5    Kallok, M.J.6
  • 15
    • 0000847359 scopus 로고
    • Effect of Amiodarone and left ventricular mass on defibrillation energy requirements; monophasic vs hiphasic shock
    • Kopp DE, Kall JG, Kinder C, Glaschock D, Wilber D (1995) Effect of Amiodarone and left ventricular mass on defibrillation energy requirements; monophasic vs hiphasic shock. PACE 18:872
    • (1995) PACE , vol.18 , pp. 872
    • Kopp, D.E.1    Kall, J.G.2    Kinder, C.3    Glaschock, D.4    Wilber, D.5
  • 16
    • 0023786718 scopus 로고
    • Relation of the intraoperative defibrillation threshold to successful prospective defibrillation with an automatic implantable cardioverter/defibrillator
    • Marchlinski FE, Flores B, Miller JM, Gottlieb CD, Hargrove WC (1988) Relation of the intraoperative defibrillation threshold to successful prospective defibrillation with an automatic implantable cardioverter/defibrillator. Am J Cardiol 62:393-398
    • (1988) Am J Cardiol , vol.62 , pp. 393-398
    • Marchlinski, F.E.1    Flores, B.2    Miller, J.M.3    Gottlieb, C.D.4    Hargrove, W.C.5
  • 17
    • 0029142613 scopus 로고
    • Increase in defibrillation threshold in non thoracotomy implantable defibrillators using a biphasic waveform
    • Martin DT, John R, Ventitti FJ (1995) Increase in defibrillation threshold in non thoracotomy implantable defibrillators using a biphasic waveform. Am J Cardiol 76:263-266
    • (1995) Am J Cardiol , vol.76 , pp. 263-266
    • Martin, D.T.1    John, R.2    Ventitti, F.J.3
  • 20
    • 0028878775 scopus 로고
    • Implantierbare kardioverter/defibrillator mit endokardialen elektrodensystemen: Langfristige stabilität der defibrillations-effektivität
    • Neuzner J, Pitchner HF, Stöhring R, Reinisch P, Schlepper M (1995) Implantierbare Kardioverter/Defibrillator mit endokardialen Elektrodensystemen: Langfristige Stabilität der Defibrillations-effektivität. Z Kardiol 84:44-50
    • (1995) Z Kardiol , vol.84 , pp. 44-50
    • Neuzner, J.1    Pitchner, H.F.2    Stöhring, R.3    Reinisch, P.4    Schlepper, M.5
  • 21
    • 0028853264 scopus 로고
    • AICD automatic cardioverter/defibrillator clinical update: 14 years experience in over 34000 patients
    • Nisam S, Kaye SA, Mover MH, Hull M (1995) AICD automatic cardioverter/defibrillator clinical update: 14 years experience in over 34000 patients. PACE 16:142-147
    • (1995) PACE , vol.16 , pp. 142-147
    • Nisam, S.1    Kaye, S.A.2    Mover, M.H.3    Hull, M.4
  • 22
    • 1842451149 scopus 로고
    • The chronic defibrillation threshold after implantation of single lead system: Long term follow-up in 32 patients
    • Perings Ch, Winter J, Kuhls S, Neuzner J (1995) The chronic defibrillation threshold after implantation of single lead system: Long term follow-up in 32 patients. PACE 18:361
    • (1995) PACE , vol.18 , pp. 361
    • Perings, Ch.1    Winter, J.2    Kuhls, S.3    Neuzner, J.4
  • 23
    • 0025917321 scopus 로고
    • Retrospective analysis of patients undergoing one-or-two-stage strategies for myocardial revascularisation and implantable cardioverter defibrillator implantation
    • Pinski SL, Mick MJ, Arnold AZ, Golding L, McCarthy PM, Castle LW, Maloney JD, Trohman RG (1991) Retrospective analysis of patients undergoing one-or-two-stage strategies for myocardial revascularisation and implantable cardioverter defibrillator implantation. PACE 14:1138-1147
    • (1991) PACE , vol.14 , pp. 1138-1147
    • Pinski, S.L.1    Mick, M.J.2    Arnold, A.Z.3    Golding, L.4    McCarthy, P.M.5    Castle, L.W.6    Maloney, J.D.7    Trohman, R.G.8
  • 25
    • 0026774142 scopus 로고
    • Prospective comparison of biphasic and monophasic shocks for implantable cardioverter-defibrillator using endocardial leads
    • Saksena S, An H, Mehra R, De Groot P, Krol RB, Burkhardt E, John T (1992) Prospective comparison of biphasic and monophasic shocks for implantable cardioverter-defibrillator using endocardial leads. Am J of Cardiol 70:304-310
    • (1992) Am J of Cardiol , vol.70 , pp. 304-310
    • Saksena, S.1    An, H.2    Mehra, R.3    De Groot, P.4    Krol, R.B.5    Burkhardt, E.6    John, T.7
  • 26
    • 0027689078 scopus 로고
    • Niederenergetische kardioversions-defibrillationsgeräte zur behandlung von ventrikulaΣren tachykardien und kammerflimmern
    • Siebels J, Schneider MAE, Kuck K-H (1993) Niederenergetische Kardioversions-Defibrillationsgeräte zur Behandlung von ventrikulaΣren Tachykardien und Kammerflimmern. Z. Kardiol., 82:683-691
    • (1993) Z Kardiol , vol.82 , pp. 683-691
    • Siebels, J.1    Schneider, M.A.E.2    Kuck, K.-H.3
  • 27
    • 0026877545 scopus 로고
    • Defibrillation threshold: Clinical utility and therapeutic implication
    • Singer I, Lang D (1992) Defibrillation threshold: clinical utility and therapeutic implication. PACE 15:932-949
    • (1992) PACE , vol.15 , pp. 932-949
    • Singer, I.1    Lang, D.2
  • 28
    • 0028334183 scopus 로고
    • Clinical outcome of patients with malignant ventricular tachyarrhythmias and a multiprogrammable implantable cardioverter-defibrillator implanted with or without thoracotomy: An international multicenter study
    • The PCD Investigator Group: (1994) Clinical outcome of patients with malignant ventricular tachyarrhythmias and a multiprogrammable implantable cardioverter-defibrillator implanted with or without thoracotomy: an international multicenter study. Am Coll Cardiol 23:1521-1530
    • (1994) Am Coll Cardiol , vol.23 , pp. 1521-1530
  • 29
    • 0028047664 scopus 로고
    • Rise in chronic defibrillation threshold in nonthoracotomy implantable defibrillator
    • Venditti FJ, Martin DT, Vassolas G, Bowen S (1994) Rise in chronic defibrillation threshold in nonthoracotomy implantable defibrillator. Circulation 89:216-223
    • (1994) Circulation , vol.89 , pp. 216-223
    • Venditti, F.J.1    Martin, D.T.2    Vassolas, G.3    Bowen, S.4
  • 30
    • 0013655003 scopus 로고
    • Analysis of first shock failure in a mulitfunctional implantable antitachycardy system. Lessons from the PRX II-Study
    • Vester EG, Ganschov US, O'Connor SA, (1995) Analysis of first shock failure in a mulitfunctional implantable antitachycardy system. Lessons from the PRX II-Study. PACE 18:363
    • (1995) PACE , vol.18 , pp. 363
    • Vester, E.G.1    Ganschov, U.S.2    O'Connor, S.A.3
  • 33
    • 0003543122 scopus 로고
    • The relationship between lower defibrillation threshold and increased implant success rate for the TRIAD lead system
    • Winkle RA, Mead RH, Ruber MA, Gaudiani VA, Smith NA, Buch WS, Schmidt P, Shipman T (1983) The relationship between lower defibrillation threshold and increased implant success rate for the TRIAD lead system. PACE 20 (4):1206
    • (1983) PACE , vol.20 , Issue.4 , pp. 1206
    • Winkle, R.A.1    Mead, R.H.2    Ruber, M.A.3    Gaudiani, V.A.4    Smith, N.A.5    Buch, W.S.6    Schmidt, P.7    Shipman, T.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.