메뉴 건너뛰기




Volumn 21, Issue 1, 1999, Pages 11-24

Technical developments in intra-operative monitoring for the preservation of cranial motor nerves and hearing in skull base surgery

Author keywords

Acoustic evoked potentials; Acoustic neuromas; Electrocochleography; Intra operative monitoring; Lower cranial nerves; Oculomotor nerves

Indexed keywords

ELECTROCOCHLEOGRAPHY; ELECTROMYOGRAPHY; EVOKED AUDITORY RESPONSE; HEARING; INTRAOPERATIVE PERIOD; MINIMALLY INVASIVE SURGERY; MOTOR NERVE; MUSCLE ACTION POTENTIAL; OCULOMOTOR NERVE; PATIENT MONITORING; REVIEW; SKULL BASE; SKULL SURGERY; TISSUE PRESERVATION;

EID: 0033059626     PISSN: 01616412     EISSN: None     Source Type: Journal    
DOI: 10.1080/01616412.1999.11740885     Document Type: Review
Times cited : (37)

References (90)
  • 2
    • 0001746003 scopus 로고
    • Operation for the total removal of cerebellopontine (acoustics) tumors
    • Dandy WE. Operation for the total removal of cerebellopontine (acoustics) tumors. Surg Gynecol Obstet 1941; 41: 29-148
    • (1941) Surg Gynecol Obstet , vol.41 , pp. 29-148
    • Dandy, W.E.1
  • 3
    • 0023190299 scopus 로고
    • Facial nerve monitoring during acoustic neuroma surgery
    • Benecke JE, Calder HB, Chadwick G. Facial nerve monitoring during acoustic neuroma surgery. Laryngoscope 1987; 97: 697-700
    • (1987) Laryngoscope , vol.97 , pp. 697-700
    • Benecke, J.E.1    Calder, H.B.2    Chadwick, G.3
  • 4
    • 0025635921 scopus 로고
    • Intraoperative monitoring of facial nerve function in cerebellopontine angle surgery
    • Hammerschlag PE, Cohen NL. Intraoperative monitoring of facial nerve function in cerebellopontine angle surgery. Otolaryngol Head Neck Surg 1990; 103: 681-684
    • (1990) Otolaryngol Head Neck Surg , vol.103 , pp. 681-684
    • Hammerschlag, P.E.1    Cohen, N.L.2
  • 5
    • 0023099839 scopus 로고
    • Improved preservation of facial nerve function with use of electrical monitoring during removal of acoustic neuromas
    • Harner SG, Daube JR, Beatty CW, Ebersold MJ. Improved preservation of facial nerve function with use of electrical monitoring during removal of acoustic neuromas. Mayo Clin Proc 1987; 62: 92-102
    • (1987) Mayo Clin Proc , vol.62 , pp. 92-102
    • Harner, S.G.1    Daube, J.R.2    Beatty, C.W.3    Ebersold, M.J.4
  • 6
    • 0002985855 scopus 로고
    • Intraoperative facial nerve monitoring: Otology, neurotology, and skull base surgery
    • Kartush JM, Bouchard KR, eds. New York: Raven Press
    • Kartush JM, Bouchard KR. Intraoperative facial nerve monitoring: Otology, neurotology, and skull base surgery. In: Kartush JM, Bouchard KR, eds. Neuromonitoring in Otology and Head and Neck Surgery, New York: Raven Press, 1991: pp. 99-120
    • (1991) Neuromonitoring in Otology and Head and Neck Surgery , pp. 99-120
    • Kartush, J.M.1    Bouchard, K.R.2
  • 7
    • 0011931259 scopus 로고
    • Prediction of facial nerve function after surgery for cerebellopontine angle tumors: Use of a facial nerve stimulator and monitor
    • Kirkpatrick PJ, Watters G, Strong AJ, Walliker JR, Gleeson MJ. Prediction of facial nerve function after surgery for cerebellopontine angle tumors: Use of a facial nerve stimulator and monitor. Skull Base Surgery 1991; 1: 171-176
    • (1991) Skull Base Surgery , vol.1 , pp. 171-176
    • Kirkpatrick, P.J.1    Watters, G.2    Strong, A.J.3    Walliker, J.R.4    Gleeson, M.J.5
  • 8
    • 0028950673 scopus 로고
    • Neurophysiological monitoring in cranial nerve surgery
    • Møller AR. Neurophysiological monitoring in cranial nerve surgery. Neurosurg Quart 1995; 5: 55-72
    • (1995) Neurosurg Quart , vol.5 , pp. 55-72
    • Møller, A.R.1
  • 10
    • 0023705532 scopus 로고
    • Routine intraoperative facial nerve monitoring during otologic surgery
    • Silverstein H, Smouha EE, Jones R. Routine intraoperative facial nerve monitoring during otologic surgery. Am J Otology 1988; 9: 269-275
    • (1988) Am J Otology , vol.9 , pp. 269-275
    • Silverstein, H.1    Smouha, E.E.2    Jones, R.3
  • 11
    • 0030786004 scopus 로고    scopus 로고
    • Incidence and predictors of bulbar palsy after surgery for acoustic neuroma
    • Duane DT, Howard SJ, Kraayenbrink M. Incidence and predictors of bulbar palsy after surgery for acoustic neuroma. J Neurosurg Anesthesiol 1997; 9: 263-268
    • (1997) J Neurosurg Anesthesiol , vol.9 , pp. 263-268
    • Duane, D.T.1    Howard, S.J.2    Kraayenbrink, M.3
  • 15
    • 0025977411 scopus 로고
    • Electrophysiologic identification and preservation of the superior laryngeal nerve during thyroid surgery
    • Eisele DE, Goldstone AC. Electrophysiologic identification and preservation of the superior laryngeal nerve during thyroid surgery. Laryngoscope 1991; 101: 313-315
    • (1991) Laryngoscope , vol.101 , pp. 313-315
    • Eisele, D.E.1    Goldstone, A.C.2
  • 16
    • 0024244910 scopus 로고
    • Intraoperative electrophysiologic monitoring of laryngeal muscle during thyroid surgery
    • Lipton RJ, McCaffrey TV, Litchy WJ. Intraoperative electrophysiologic monitoring of laryngeal muscle during thyroid surgery. Laryngoscope 1988; 98: 1292-1296
    • (1988) Laryngoscope , vol.98 , pp. 1292-1296
    • Lipton, R.J.1    McCaffrey, T.V.2    Litchy, W.J.3
  • 17
    • 0027485542 scopus 로고
    • Posterior Fossa intraoperative monitoring
    • Cheek JC. Posterior Fossa intraoperative monitoring. J Clin Neurophysiol 1993; 10: 412-424
    • (1993) J Clin Neurophysiol , vol.10 , pp. 412-424
    • Cheek, J.C.1
  • 18
    • 0012440508 scopus 로고
    • Regional monitoring of the lower (ninth through twelfth) cranial nerves
    • Kartush JM, Bouchard KR, eds. New York: Raven Press
    • Lanser MJ, Jackler RK, Yingling D. Regional monitoring of the lower (ninth through twelfth) cranial nerves. In: Kartush JM, Bouchard KR, eds. Neuromonitoring in Otology and Head and Neck Surgery, New York: Raven Press, 1991: pp. 131-150
    • (1991) Neuromonitoring in Otology and Head and Neck Surgery , pp. 131-150
    • Lanser, M.J.1    Jackler, R.K.2    Yingling, D.3
  • 20
    • 0022541747 scopus 로고
    • Operative management of tumors involving the cavernous sinus
    • Sekhar LN, Møller AR. Operative management of tumors involving the cavernous sinus. J Neurosurg 1986; 64: 879-889
    • (1986) J Neurosurg , vol.64 , pp. 879-889
    • Sekhar, L.N.1    Møller, A.R.2
  • 22
    • 0027233493 scopus 로고
    • The preservation of hearing and facial nerve function in a consecutive series of unilateral vestibular schwannoma surgical patients (acoustic neuroma)
    • Cerullo LJ, Grutsch JF, Heiferman K, Osterdock R. The preservation of hearing and facial nerve function in a consecutive series of unilateral vestibular schwannoma surgical patients (acoustic neuroma). Surg Neurol 1993; 39: 485-493
    • (1993) Surg Neurol , vol.39 , pp. 485-493
    • Cerullo, L.J.1    Grutsch, J.F.2    Heiferman, K.3    Osterdock, R.4
  • 23
    • 0022577132 scopus 로고
    • Acoustic neuroma surgery: An eclectic approach with emphasis on preservation of hearing. The New York University-Bellevue experience
    • Cohen NL, Hammerschlag P, Berg H, Ransohoff J. Acoustic neuroma surgery: An eclectic approach with emphasis on preservation of hearing. The New York University-Bellevue experience. Ann Otol Rhinol Laryngol 1986; 95: 21-27
    • (1986) Ann Otol Rhinol Laryngol , vol.95 , pp. 21-27
    • Cohen, N.L.1    Hammerschlag, P.2    Berg, H.3    Ransohoff, J.4
  • 24
    • 0026642227 scopus 로고
    • Hearing preservation in acoustic neurinoma surgery
    • Fischer G, Fischer C, Rémond J. Hearing preservation in acoustic neurinoma surgery. J Neurosurg 1992; 76: 910-917
    • (1992) J Neurosurg , vol.76 , pp. 910-917
    • Fischer, G.1    Fischer, C.2    Rémond, J.3
  • 25
    • 0023837828 scopus 로고
    • Hearing preservation in unilateral acoustic neuroma surgery
    • Gardner G, Robertson JH. Hearing preservation in unilateral acoustic neuroma surgery. Ann Otol Rhinol Laryngol 1988; 97: 55-66
    • (1988) Ann Otol Rhinol Laryngol , vol.97 , pp. 55-66
    • Gardner, G.1    Robertson, J.H.2
  • 28
    • 0030837429 scopus 로고    scopus 로고
    • Hearing preservation after acoustic neuroma resection with tumor size used as a clinical prognosticator
    • Hecht CS, Honrubia VF, Wiet RJ, Sims S. Hearing preservation after acoustic neuroma resection with tumor size used as a clinical prognosticator. Laryngoscope 1997; 107: 1122-1126
    • (1997) Laryngoscope , vol.107 , pp. 1122-1126
    • Hecht, C.S.1    Honrubia, V.F.2    Wiet, R.J.3    Sims, S.4
  • 29
    • 0021232966 scopus 로고
    • Monitoring auditory nerve potentials during operations in the cerebellopontine angle
    • Møller AR, Janetta PJ. Monitoring auditory nerve potentials during operations in the cerebellopontine angle. Otolaryngol Head Neck Surg 1984; 92: 434-439
    • (1984) Otolaryngol Head Neck Surg , vol.92 , pp. 434-439
    • Møller, A.R.1    Janetta, P.J.2
  • 30
    • 0031013439 scopus 로고    scopus 로고
    • Management of 1000 vestibular schwannomas (acoustic neuromas): Hearing function in 1000 tumor resections
    • Samii M, Matthies C. Management of 1000 vestibular schwannomas (acoustic neuromas): Hearing function in 1000 tumor resections. Neurosurgery 1997; 40: 248-262
    • (1997) Neurosurgery , vol.40 , pp. 248-262
    • Samii, M.1    Matthies, C.2
  • 33
    • 0025270137 scopus 로고
    • Intraoperative facial nerve monitoring. Technical aspects
    • Beck D. Intraoperative facial nerve monitoring. Technical aspects. Otolaryngol Head Neck Surg 1990; 102: 270-272
    • (1990) Otolaryngol Head Neck Surg , vol.102 , pp. 270-272
    • Beck, D.1
  • 35
    • 0026031847 scopus 로고
    • A comparison of facial nerve systems in cerebellopontine angle surgery
    • Dickins JRE, Graham SS. A comparison of facial nerve systems in cerebellopontine angle surgery. Am J Otol 1991; 12: 1-6
    • (1991) Am J Otol , vol.12 , pp. 1-6
    • Dickins, J.R.E.1    Graham, S.S.2
  • 36
    • 0024467816 scopus 로고
    • Electroneurography and intraoperative facial monitoring in contemporary neurotology
    • Kartush JM. Electroneurography and intraoperative facial monitoring in contemporary neurotology. Otolaryngol Head Neck Surg 1989; 101: 496-503
    • (1989) Otolaryngol Head Neck Surg , vol.101 , pp. 496-503
    • Kartush, J.M.1
  • 38
    • 0021228195 scopus 로고
    • Preservation of facial function during removal of acoustic neuromas. Use of monopolar constant-voltage stimulation and EMG
    • Møller AR, Janetta P. Preservation of facial function during removal of acoustic neuromas. Use of monopolar constant-voltage stimulation and EMG. J Neurosurg 1984; 61: 757-760
    • (1984) J Neurosurg , vol.61 , pp. 757-760
    • Møller, A.R.1    Janetta, P.2
  • 40
    • 0022551707 scopus 로고
    • Acoustic (loudspeaker) facial electromyographic monitoring: Part 1. Evoked electromyographic activity during acoustic neuroma resection
    • Prass R, Lüders H. Acoustic (loudspeaker) facial electromyographic monitoring: Part 1. Evoked electromyographic activity during acoustic neuroma resection. Neurosurgery 1986; 19: 392-400
    • (1986) Neurosurgery , vol.19 , pp. 392-400
    • Prass, R.1    Lüders, H.2
  • 41
    • 0002009215 scopus 로고
    • Intraoperative electromyographic recordings
    • Kartush JM, Bouchard KR, eds. New York: Raven Press
    • Prass R. Intraoperative electromyographic recordings. In: Kartush JM, Bouchard KR, eds. Neuromonitoring in Otology and Head and Neck Surgery, New York: Raven Press, 1991: pp. 81-97
    • (1991) Neuromonitoring in Otology and Head and Neck Surgery , pp. 81-97
    • Prass, R.1
  • 42
    • 0000825286 scopus 로고
    • Zur freilegung der hinteren felsenbeinfläche und des kleinhirns
    • Krause F. Zur Freilegung der hinteren Felsenbeinfläche und des Kleinhirns. Beitr Klin Chir 1903; 37: 728-764
    • (1903) Beitr Klin Chir , vol.37 , pp. 728-764
    • Krause, F.1
  • 43
    • 0018657211 scopus 로고
    • Intraoperative monitoring of facial muscle evoked responses obtained by intracranial stimulation of the facial nerve: A more accurate technique for facial nerve dissection
    • Delgado TE, Buchheit WA, Rosenholtz HR, Chrissian S. Intraoperative monitoring of facial muscle evoked responses obtained by intracranial stimulation of the facial nerve: A more accurate technique for facial nerve dissection. Neurosurgery 1979; 4: 418-421
    • (1979) Neurosurgery , vol.4 , pp. 418-421
    • Delgado, T.E.1    Buchheit, W.A.2    Rosenholtz, H.R.3    Chrissian, S.4
  • 44
    • 0020393552 scopus 로고
    • Technical and instrumental improvements in the surgical treatment of acoustic neurinomas
    • Sugita K, Kobayashi S. Technical and instrumental improvements in the surgical treatment of acoustic neurinomas. J Neurosurg 1982; 57: 747-752
    • (1982) J Neurosurg , vol.57 , pp. 747-752
    • Sugita, K.1    Kobayashi, S.2
  • 45
    • 0028258374 scopus 로고
    • Investigation of a coaxial bipolar nerve stimulator for intraoperative motor nerve monitoring
    • Danke JA, Wiegand DA. Investigation of a coaxial bipolar nerve stimulator for intraoperative motor nerve monitoring. Laryngoscope 1994; 104: 619-622
    • (1994) Laryngoscope , vol.104 , pp. 619-622
    • Danke, J.A.1    Wiegand, D.A.2
  • 46
    • 0029938963 scopus 로고    scopus 로고
    • Coaxial insulated bipolar electrode for monopolar and bipolar mapping of neural tissue: Technical note with emphasis on the principles of intra-operative stimulation
    • Schekutiev G, Schmid UD. Coaxial insulated bipolar electrode for monopolar and bipolar mapping of neural tissue: Technical note with emphasis on the principles of intra-operative stimulation. Acta Neurochir 1996; 138: 470-474
    • (1996) Acta Neurochir , vol.138 , pp. 470-474
    • Schekutiev, G.1    Schmid, U.D.2
  • 47
    • 0030774474 scopus 로고    scopus 로고
    • Intraoperative monitoring of facial nerve antidromic potentials during acoustic neuroma surgery
    • Colletti V, Fiorino F, Policante Z, Bruni L. Intraoperative monitoring of facial nerve antidromic potentials during acoustic neuroma surgery. Acta Otolaryngol 1997; 117: 663-669
    • (1997) Acta Otolaryngol , vol.117 , pp. 663-669
    • Colletti, V.1    Fiorino, F.2    Policante, Z.3    Bruni, L.4
  • 48
    • 0030983041 scopus 로고    scopus 로고
    • Value of intraoperative threshold stimulus in predicting postoperative facial nerve function after acoustic tumor resection
    • Nissen AJ, Sikand A, Curto FS, Welsh JE, Gardi J. Value of intraoperative threshold stimulus in predicting postoperative facial nerve function after acoustic tumor resection. Am J Otol 1997; 18: 249-251
    • (1997) Am J Otol , vol.18 , pp. 249-251
    • Nissen, A.J.1    Sikand, A.2    Curto, F.S.3    Welsh, J.E.4    Gardi, J.5
  • 49
    • 0028028340 scopus 로고
    • Facial nerve outcome after acoustic neuroma surgery. A study from the area of cranial nerve monitoring
    • Lalwani AK, Butt FY, Jackler RK, Pitts LH, Yingling CD. Facial nerve outcome after acoustic neuroma surgery. A study from the area of cranial nerve monitoring. Otolaryngol Head Neck Surg 1994; 111: 561-570
    • (1994) Otolaryngol Head Neck Surg , vol.111 , pp. 561-570
    • Lalwani, A.K.1    Butt, F.Y.2    Jackler, R.K.3    Pitts, L.H.4    Yingling, C.D.5
  • 51
    • 0021272127 scopus 로고
    • Monitoring auditory evoked potentials during acoustic neuroma surgery. Insights into the mechanism of the hearing loss
    • Levine RA, Ojemann RG, Montgomery WW, McGaffigan P. Monitoring auditory evoked potentials during acoustic neuroma surgery. Insights into the mechanism of the hearing loss. Ann Otol Rhinol Laryngol 1984; 93: 116-123
    • (1984) Ann Otol Rhinol Laryngol , vol.93 , pp. 116-123
    • Levine, R.A.1    Ojemann, R.G.2    Montgomery, W.W.3    McGaffigan, P.4
  • 52
    • 0026642227 scopus 로고
    • Hearing preservation in acoustic neuroma surgery
    • Fischer G, Fischer C, Rémond J. Hearing preservation in acoustic neuroma surgery. J Neurosurg 1992; 76: 910-917
    • (1992) J Neurosurg , vol.76 , pp. 910-917
    • Fischer, G.1    Fischer, C.2    Rémond, J.3
  • 55
    • 0023851215 scopus 로고
    • Electrophysiological monitoring during acoustic neuroma and other posterior fossa surgery
    • Linden RD, Tator CH, Benedict C, Charles D, Mraz V, Bell I. Electrophysiological monitoring during acoustic neuroma and other posterior fossa surgery. Can J Neurol Sci 1988; 15: 73-81
    • (1988) Can J Neurol Sci , vol.15 , pp. 73-81
    • Linden, R.D.1    Tator, C.H.2    Benedict, C.3    Charles, D.4    Mraz, V.5    Bell, I.6
  • 56
    • 0031019256 scopus 로고    scopus 로고
    • Management of vestibular schwannomas (acoustic neuromas): The value of neurophysiology for intraoperative monitoring of auditory function in 200 cases
    • Matthies C, Samii M. Management of vestibular schwannomas (acoustic neuromas): The value of neurophysiology for intraoperative monitoring of auditory function in 200 cases. Neurosurgery 1997; 40: 459-468
    • (1997) Neurosurgery , vol.40 , pp. 459-468
    • Matthies, C.1    Samii, M.2
  • 57
    • 0010595724 scopus 로고
    • Use of brainstem auditory evoked potentials in intraoperative neurophysiologic monitoring
    • Kartush JM, Bouchard KR, eds. New York: Raven Press
    • Møller AR. Use of brainstem auditory evoked potentials in intraoperative neurophysiologic monitoring. In: Kartush JM, Bouchard KR, eds. Neuromonitoring in Otology and Head and Neck Surgery, New York: Raven Press, 1991: pp. 199-214
    • (1991) Neuromonitoring in Otology and Head and Neck Surgery , pp. 199-214
    • Møller, A.R.1
  • 58
    • 0025731312 scopus 로고
    • Auditory nerve compound action potentials and brain stem auditory evoked potentials in patients with various degrees of hearing loss
    • Møller AR, Møller MB, Janetta PJ, Jho HD. Auditory nerve compound action potentials and brain stem auditory evoked potentials in patients with various degrees of hearing loss. Ann Otol Rhinol Laryngol 1991; 100: 488-495
    • (1991) Ann Otol Rhinol Laryngol , vol.100 , pp. 488-495
    • Møller, A.R.1    Møller, M.B.2    Janetta, P.J.3    Jho, H.D.4
  • 59
    • 0021686447 scopus 로고
    • Use of intraoperative auditory evoked potentials to preserve hearing in unilateral acoustic neuroma removal
    • Ojemann RG, Levine RA, Montgomery WM, McGaffigan P. Use of intraoperative auditory evoked potentials to preserve hearing in unilateral acoustic neuroma removal. J Neurosurg 1984; 61: 938-948
    • (1984) J Neurosurg , vol.61 , pp. 938-948
    • Ojemann, R.G.1    Levine, R.A.2    Montgomery, W.M.3    McGaffigan, P.4
  • 60
    • 0022976791 scopus 로고
    • Hearing preservation after acoustic neuroma surgery with intraoperative direct eighth cranial nerve monitoring. Part II. A classification of results
    • Silverstein H, McDaniel AB, Norrel H, Haberkamp T. Hearing preservation after acoustic neuroma surgery with intraoperative direct eighth cranial nerve monitoring. Part II. A classification of results. Otolaryngol Head Neck Surg 1986; 95: 285-291
    • (1986) Otolaryngol Head Neck Surg , vol.95 , pp. 285-291
    • Silverstein, H.1    McDaniel, A.B.2    Norrel, H.3    Haberkamp, T.4
  • 62
    • 0021867419 scopus 로고
    • Intraoperative brain-stem auditory evoked potentials during posterior fossa microvascular decompression
    • Friedman WA, Kaplan BJ, Gravenstein D, Rhoton AL. Intraoperative brain-stem auditory evoked potentials during posterior fossa microvascular decompression. J Neurosurg 1985; 62: 552-557
    • (1985) J Neurosurg , vol.62 , pp. 552-557
    • Friedman, W.A.1    Kaplan, B.J.2    Gravenstein, D.3    Rhoton, A.L.4
  • 63
    • 0030460332 scopus 로고    scopus 로고
    • Contralateral evoked brainstem auditory potentials as an indicator of intraoperative brainstem manipulation in cerebellopontine angle tumors
    • Angelo R, Møller AR. Contralateral evoked brainstem auditory potentials as an indicator of intraoperative brainstem manipulation in cerebellopontine angle tumors. Neural Res 1996; 18: 528-540
    • (1996) Neural Res , vol.18 , pp. 528-540
    • Angelo, R.1    Møller, A.R.2
  • 64
    • 0344174790 scopus 로고
    • Physiology of the auditory system and recording of auditory evoked potentials
    • Kartush JM, Bouchard KR, eds. New York: Raven Press
    • Møller AR. Physiology of the auditory system and recording of auditory evoked potentials. In: Kartush JM, Bouchard KR, eds. Neuromonitoring in Otology and Head and Neck Surgery, New York: Raven Press, 1991: pp. 81-97
    • (1991) Neuromonitoring in Otology and Head and Neck Surgery , pp. 81-97
    • Møller, A.R.1
  • 65
    • 0021876952 scopus 로고
    • A new interpretation of the generators of BAEP waves I-V: Results of spatio-temporal dipole
    • Scherg M, von Carmon D. A new interpretation of the generators of BAEP waves I-V: Results of spatio-temporal dipole. Electroenceph Clin Neurophysiol 1985; 62: 290-299
    • (1985) Electroenceph Clin Neurophysiol , vol.62 , pp. 290-299
    • Scherg, M.1    Von Carmon, D.2
  • 66
    • 0023948237 scopus 로고
    • Detailed analysis of intraoperative changes monitoring brain stem acoustic evoked potentials
    • Schramm J, Mokrusch T, Fahlbusch R, Hochstetter A. Detailed analysis of intraoperative changes monitoring brain stem acoustic evoked potentials. Neurosurgery 1988; 22: 694-702
    • (1988) Neurosurgery , vol.22 , pp. 694-702
    • Schramm, J.1    Mokrusch, T.2    Fahlbusch, R.3    Hochstetter, A.4
  • 67
    • 0027330413 scopus 로고
    • Electrophysiologic identification of the cochlear nerve fibers during cerebello-pontine angle surgery
    • Colletti V, Riorino FC. Electrophysiologic identification of the cochlear nerve fibers during cerebello-pontine angle surgery. Acta Otolaryngol 1993; 113: 746-753
    • (1993) Acta Otolaryngol , vol.113 , pp. 746-753
    • Colletti, V.1    Riorino, F.C.2
  • 68
    • 0028243761 scopus 로고
    • Vulnerability of hearing function during acoustic neuroma surgery
    • Colletti V, Fiorino FG. Vulnerability of hearing function during acoustic neuroma surgery. Acta Otolaryngol 1994; 114: 264-270
    • (1994) Acta Otolaryngol , vol.114 , pp. 264-270
    • Colletti, V.1    Fiorino, F.G.2
  • 69
    • 0028202167 scopus 로고
    • Preservation of hearing in operations on acoustic tumors: An alternative to recording brainstem auditory evoked potentials
    • Møller AR, Jho HD, Janetta PJ. Preservation of hearing in operations on acoustic tumors: An alternative to recording brainstem auditory evoked potentials. Neurosurgery 1994; 34: 688-693
    • (1994) Neurosurgery , vol.34 , pp. 688-693
    • Møller, A.R.1    Jho, H.D.2    Janetta, P.J.3
  • 70
    • 0030035560 scopus 로고    scopus 로고
    • Direct cochlear nerve action potential as an aid to hearing preservation in middle fossa acoustic neuroma resection
    • Roberson J, Senne A, Brackmann DE, Hitselberger WE, Saunders J. Direct cochlear nerve action potential as an aid to hearing preservation in middle fossa acoustic neuroma resection. Am J Otol 1996; 17: 653-657
    • (1996) Am J Otol , vol.17 , pp. 653-657
    • Roberson, J.1    Senne, A.2    Brackmann, D.E.3    Hitselberger, W.E.4    Saunders, J.5
  • 71
    • 0022272661 scopus 로고
    • Hearing preservation after acoustic neuroma surgery using intraoperative direct eight cranial nerve monitoring
    • Silverstein H, McDaniel AB, Norrell H. Hearing preservation after acoustic neuroma surgery using intraoperative direct eight cranial nerve monitoring. Am J Otology 1985; 6 (Suppl.): 99-106
    • (1985) Am J Otology , vol.6 , Issue.SUPPL. , pp. 99-106
    • Silverstein, H.1    McDaniel, A.B.2    Norrell, H.3
  • 72
    • 0030966471 scopus 로고    scopus 로고
    • Direct brainstem recording of auditory evoked potentials during vestibular schwannoma resection: Nuclear BAEP
    • Matthies C, Samii M. Direct brainstem recording of auditory evoked potentials during vestibular schwannoma resection: Nuclear BAEP. J Neurosurg 1997; 86: 1057-1062
    • (1997) J Neurosurg , vol.86 , pp. 1057-1062
    • Matthies, C.1    Samii, M.2
  • 73
    • 0029002608 scopus 로고
    • Microsurgical anatomy around the foramen of Luschka in relation to intraoperative recording of auditory evoked potentials from the cochlear nuclei
    • Kuroki A, Møller AR. Microsurgical anatomy around the foramen of Luschka in relation to intraoperative recording of auditory evoked potentials from the cochlear nuclei. J Neurosurg 1995; 82: 933-939
    • (1995) J Neurosurg , vol.82 , pp. 933-939
    • Kuroki, A.1    Møller, A.R.2
  • 75
    • 0023631895 scopus 로고
    • Transtragel, transtympanic electrode placement for intraoperative electrocochleographic monitoring
    • Prass R, Kinney SE, Lüders H. Transtragel, transtympanic electrode placement for intraoperative electrocochleographic monitoring. Otolaryngol Head Neck Surg 1987; 97: 343-350
    • (1987) Otolaryngol Head Neck Surg , vol.97 , pp. 343-350
    • Prass, R.1    Kinney, S.E.2    Lüders, H.3
  • 76
    • 0023733373 scopus 로고
    • Electrocochleography: Methods and clinical applications
    • Ruth RA, Lambert PR, Ferraro JA. Electrocochleography: Methods and clinical applications. Am J Otol 1988; 9 (Suppl.): 1-11
    • (1988) Am J Otol , vol.9 , Issue.SUPPL. , pp. 1-11
    • Ruth, R.A.1    Lambert, P.R.2    Ferraro, J.A.3
  • 78
    • 0026783139 scopus 로고
    • Intraoperative monitoring by transtympanic electrocochleography and brainstem electrical response audiometry in acoustic neuroma surgery
    • Lenarz T, Ernst A. Intraoperative monitoring by transtympanic electrocochleography and brainstem electrical response audiometry in acoustic neuroma surgery. Arch Otorhinolaryngol 1992; 249: 257-262
    • (1992) Arch Otorhinolaryngol , vol.249 , pp. 257-262
    • Lenarz, T.1    Ernst, A.2
  • 79
    • 0024503459 scopus 로고
    • Cochlear nerve action potentials during cerebellopontine angle surgery: Relationship of latency, amplitude, and threshold measurements to hearing
    • Stanton SG, Cashman MZ, Harrison RV, Nedzelski JM, Rowed DW. Cochlear nerve action potentials during cerebellopontine angle surgery: Relationship of latency, amplitude, and threshold measurements to hearing. Ear Hear 1989; 10: 23-28
    • (1989) Ear Hear , vol.10 , pp. 23-28
    • Stanton, S.G.1    Cashman, M.Z.2    Harrison, R.V.3    Nedzelski, J.M.4    Rowed, D.W.5
  • 80
    • 0027393506 scopus 로고
    • Tympanic and transtympanic electrocochleography in acoustic neuroma and vestibular nerve section surgery
    • Winzenburg SM, Margolis RH, Levine SC, Haines SJ, Fournier EM. Tympanic and transtympanic electrocochleography in acoustic neuroma and vestibular nerve section surgery. Am J Otol 1993; 14: 63-69
    • (1993) Am J Otol , vol.14 , pp. 63-69
    • Winzenburg, S.M.1    Margolis, R.H.2    Levine, S.C.3    Haines, S.J.4    Fournier, E.M.5
  • 81
    • 0025944810 scopus 로고
    • Extratympanic electrocochleograph with a conductive fluid and flexible electrode
    • Nowosielski JE, Redhead J, Kattula SP. Extratympanic electrocochleograph with a conductive fluid and flexible electrode. Br J Audiol 1991; 25: 345-349
    • (1991) Br J Audiol , vol.25 , pp. 345-349
    • Nowosielski, J.E.1    Redhead, J.2    Kattula, S.P.3
  • 82
    • 0023430197 scopus 로고
    • Clinical evaluation of a new ECoG recording electrode
    • Stypulkowski PH, Staller SJ. Clinical evaluation of a new ECoG recording electrode. Ear Hear 1987; 8: 304-310
    • (1987) Ear Hear , vol.8 , pp. 304-310
    • Stypulkowski, P.H.1    Staller, S.J.2
  • 83
    • 0023502220 scopus 로고
    • Avulsion rupture of the internal auditory artery during operations in the cerebellopontine angle: A study in monkeys
    • Sekiya T, Møller AR. Avulsion rupture of the internal auditory artery during operations in the cerebellopontine angle: A study in monkeys. Neurosurgery 1987; 21: 631-637
    • (1987) Neurosurgery , vol.21 , pp. 631-637
    • Sekiya, T.1    Møller, A.R.2
  • 84
    • 0027935818 scopus 로고
    • The disconnected ear: Phenomenological effects of a large acoustic tumor
    • Cacace AT, Parnes SM, Lovely TJ, Kalthia A. The disconnected ear: Phenomenological effects of a large acoustic tumor, Ear Hear 1994; 15: 287-298
    • (1994) Ear Hear , vol.15 , pp. 287-298
    • Cacace, A.T.1    Parnes, S.M.2    Lovely, T.J.3    Kalthia, A.4
  • 85
    • 0023716867 scopus 로고
    • Electrically evoked brainstem potentials in cochlear implant patients with multi-electrode stimulation
    • Abbas PJ, Brown CJ. Electrically evoked brainstem potentials in cochlear implant patients with multi-electrode stimulation. Hearing Res 1988; 36: 153-162
    • (1988) Hearing Res , vol.36 , pp. 153-162
    • Abbas, P.J.1    Brown, C.J.2
  • 86
    • 0018382113 scopus 로고
    • Auditory brainstem potentials in man evoked by electrical stimulation of the round window
    • Chouard CH, Meyer B, Donadieu F. Auditory brainstem potentials in man evoked by electrical stimulation of the round window. Acta Otolaryngol 1979; 87: 287-293
    • (1979) Acta Otolaryngol , vol.87 , pp. 287-293
    • Chouard, C.H.1    Meyer, B.2    Donadieu, F.3
  • 87
  • 88
    • 0022636918 scopus 로고
    • Characterization of the electrically evoked brainstem response (ABR) in cats and humans
    • van den Honert C, Stypulkowski PH. Characterization of the electrically evoked brainstem response (ABR) in cats and humans. Hearing Res 1986; 21: 109-126
    • (1986) Hearing Res , vol.21 , pp. 109-126
    • Van Den Honert, C.1    Stypulkowski, P.H.2
  • 89
    • 0023547223 scopus 로고
    • Electrically evoked middle-latency auditory potentials in cochlear implant candidates
    • Kileny PR, Kemink JL. Electrically evoked middle-latency auditory potentials in cochlear implant candidates. Arch Otolaryngol Head Neck Surg 1987; 113: 1072-1077
    • (1987) Arch Otolaryngol Head Neck Surg , vol.113 , pp. 1072-1077
    • Kileny, P.R.1    Kemink, J.L.2
  • 90
    • 0030977838 scopus 로고    scopus 로고
    • Electrically evoked auditory brainstem response by direct electrical stimulation to the cochlear nerve in acoustic neuroma patients
    • Tanaka H, Komatsuzaki A, Okuno H. Electrically evoked auditory brainstem response by direct electrical stimulation to the cochlear nerve in acoustic neuroma patients. ORL 1997; 59: 67-72
    • (1997) ORL , vol.59 , pp. 67-72
    • Tanaka, H.1    Komatsuzaki, A.2    Okuno, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.