메뉴 건너뛰기




Volumn 26, Issue 6, 1999, Pages 992-1006

On-line monitoring of radiotherapy beams: Experimental results with proton beams

Author keywords

Isotopic imaging; Nuclear activation; Proton radiotherapy; Range verification

Indexed keywords

GAMMA RAYS; IMAGE RESOLUTION; IMAGING SYSTEMS; ISOTOPES; POSITRONS; PROTON BEAMS; RADIOTHERAPY; TISSUE;

EID: 0033057538     PISSN: 00942405     EISSN: None     Source Type: Journal    
DOI: 10.1118/1.598491     Document Type: Article
Times cited : (93)

References (53)
  • 1
    • 0026515872 scopus 로고
    • Differential-pencil-beam dose calculations for charged particles
    • P. L. Petti, "Differential-pencil-beam dose calculations for charged particles," Med. Phys. 19, 137-149 (1992).
    • (1992) Med. Phys. , vol.19 , pp. 137-149
    • Petti, P.L.1
  • 2
    • 0017621510 scopus 로고
    • The measurement of tissue heterodensity to guide charged particle radiotherapy
    • M. Goitein, "The measurement of tissue heterodensity to guide charged particle radiotherapy," Int. J. Radiat. Oncol., Biol., Phys. 3, 27-33 (1977).
    • (1977) Int. J. Radiat. Oncol., Biol., Phys. , vol.3 , pp. 27-33
    • Goitein, M.1
  • 3
    • 0018143405 scopus 로고
    • The influence of thick inhomogeneities on charged particle beams
    • M. Goitein and J. M. Sisterson, "The influence of thick inhomogeneities on charged particle beams," Radiat. Res. 74, 217-230 (1978).
    • (1978) Radiat. Res. , vol.74 , pp. 217-230
    • Goitein, M.1    Sisterson, J.M.2
  • 4
    • 0018099879 scopus 로고
    • Compensation for inhomogeneities in charged particle radiotherapy using computed tomography
    • M. Goitein, "Compensation for inhomogeneities in charged particle radiotherapy using computed tomography," Int. J. Oncol., Biol., Phys. 4, 499-508 (1978).
    • (1978) Int. J. Oncol., Biol., Phys. , vol.4 , pp. 499-508
    • Goitein, M.1
  • 5
    • 0020681789 scopus 로고
    • The relation between X-ray CT numbers and charged particle stopping powers and its significance for radio-therapy treatment planning
    • A. A. Mustafa and D. F. Jackson, "The relation between X-ray CT numbers and charged particle stopping powers and its significance for radio-therapy treatment planning," Phys. Med. Biol. 28, 169-176 (1983).
    • (1983) Phys. Med. Biol. , vol.28 , pp. 169-176
    • Mustafa, A.A.1    Jackson, D.F.2
  • 6
    • 0021825245 scopus 로고
    • A comparison of water equivalent thickness measurements: CT method vs heavy ion beam technique
    • E. L. Alpen, W. Saunders, A. Chatterjee, J. Llacer, G. T. Y. Chen, and J. Scherer, "A comparison of water equivalent thickness measurements: CT method vs heavy ion beam technique," Br. J. Radiol. 58, 542-548 (1985).
    • (1985) Br. J. Radiol. , vol.58 , pp. 542-548
    • Alpen, E.L.1    Saunders, W.2    Chatterjee, A.3    Llacer, J.4    Chen, G.T.Y.5    Scherer, J.6
  • 7
    • 37049237402 scopus 로고
    • Analysis of microcomposition of biological tissue by means of induced radioactivity
    • C. A. Tobias, "Analysis of microcomposition of biological tissue by means of induced radioactivity," Science 109, 109-113 (1949).
    • (1949) Science , vol.109 , pp. 109-113
    • Tobias, C.A.1
  • 8
    • 33744593835 scopus 로고
    • Production of radio-activity in animal tissues by high-energy X-rays
    • London
    • M. V. Mayneord, J. H. Martin, and D. A. Layne, "Production of radio-activity in animal tissues by high-energy X-rays," Nature (London) 164, 728-730 (1949).
    • (1949) Nature , vol.164 , pp. 728-730
    • Mayneord, M.V.1    Martin, J.H.2    Layne, D.A.3
  • 9
    • 0018761438 scopus 로고
    • Tissue perfusion rate determined from the decay of oxygen-15 activity after photon activation in situ
    • W. L. Hughes, G. H. Nussbaum, R. Connolly, B. Emami, and P. Reilly, "Tissue perfusion rate determined from the decay of oxygen-15 activity after photon activation in situ," Science 204, 1215-1216 (1979).
    • (1979) Science , vol.204 , pp. 1215-1216
    • Hughes, W.L.1    Nussbaum, G.H.2    Connolly, R.3    Emami, B.4    Reilly, P.5
  • 12
    • 0018224762 scopus 로고
    • Visualization and transport of positron emission from proton activation in vivo
    • G. W. Bennett, J. O. Archambeau, B. E. Archambeau, J. I. Meltzer, and C. L. Wingate, "Visualization and transport of positron emission from proton activation in vivo," Science 200, 1151-1152 (1978).
    • (1978) Science , vol.200 , pp. 1151-1152
    • Bennett, G.W.1    Archambeau, J.O.2    Archambeau, B.E.3    Meltzer, J.I.4    Wingate, C.L.5
  • 13
    • 0020619214 scopus 로고
    • Activation of the major constituents of tissue and air by a fast neutron radiation therapy beam
    • R. K. Ten Haken, M. Awschalom, and I. Rosenberg, "Activation of the major constituents of tissue and air by a fast neutron radiation therapy beam," Med. Phys. 10, 636-641 (1983).
    • (1983) Med. Phys. , vol.10 , pp. 636-641
    • Ten Haken, R.K.1    Awschalom, M.2    Rosenberg, I.3
  • 14
    • 0014960592 scopus 로고
    • Pion cancer therapy: Positron activity as an indicator of depth-dose
    • M. C. Taylor, "Pion cancer therapy: Positron activity as an indicator of depth-dose," Science 169, 377-378 (1970).
    • (1970) Science , vol.169 , pp. 377-378
    • Taylor, M.C.1
  • 17
    • 0014493044 scopus 로고
    • Tissue activation studies with alpha-particle beams
    • H. D. Maccabee, U. Madhvanath, and M. R. Raju, "Tissue activation studies with alpha-particle beams," Phys. Med. Biol. 14, 213-224 (1969).
    • (1969) Phys. Med. Biol. , vol.14 , pp. 213-224
    • Maccabee, H.D.1    Madhvanath, U.2    Raju, M.R.3
  • 20
    • 0004143102 scopus 로고
    • An assessment of the role of charged secondaries from nonelastic nuclear interactions by therapy proton beams in water
    • June
    • S. M. Seltzer, "An assessment of the role of charged secondaries from nonelastic nuclear interactions by therapy proton beams in water," National Institute of Standards and Technology report NISTIR 5221, June, 1993.
    • (1993) National Institute of Standards and Technology Report NISTIR 5221
    • Seltzer, S.M.1
  • 21
    • 0030189580 scopus 로고    scopus 로고
    • Effects of nuclear interactions on energy and stopping power in proton beam dosimetry
    • R. F. Laitano, M. Rosetti and M. Frisoni, "Effects of nuclear interactions on energy and stopping power in proton beam dosimetry," Nucl. Instrum. Methods Phys. Res. A 376, 446-476 (1996).
    • (1996) Nucl. Instrum. Methods Phys. Res. A , vol.376 , pp. 446-476
    • Laitano, R.F.1    Rosetti, M.2    Frisoni, M.3
  • 23
    • 0014277509 scopus 로고
    • A formalism for calculation of absorbed dose from radionuclides
    • R. Loevinger and M. Berman, "A formalism for calculation of absorbed dose from radionuclides," Phys. Med. Biol. 13, 205-217 (1976).
    • (1976) Phys. Med. Biol. , vol.13 , pp. 205-217
    • Loevinger, R.1    Berman, M.2
  • 27
    • 0027572364 scopus 로고
    • Is it possible to verify directly a proton-treatment plan using positron emission tomography
    • S. Vynckier, S. Derreumaux, F. Richard, A. Bol, C. Michel, and A. Wambersie, "Is it possible to verify directly a proton-treatment plan using positron emission tomography," Radiother. Oncol. 26, 275-277 (1993).
    • (1993) Radiother. Oncol. , vol.26 , pp. 275-277
    • Vynckier, S.1    Derreumaux, S.2    Richard, F.3    Bol, A.4    Michel, C.5    Wambersie, A.6
  • 28
    • 0027649740 scopus 로고
    • Proton therapy in combination with PET as monitor: A feasibility study
    • A. M. J. Paans and J. M. Schippers, "Proton therapy in combination with PET as monitor: A feasibility study," IEEE Trans. Nucl. Sci. 40, 1041-1044 (1993).
    • (1993) IEEE Trans. Nucl. Sci. , vol.40 , pp. 1041-1044
    • Paans, A.M.J.1    Schippers, J.M.2
  • 29
    • 0030025292 scopus 로고    scopus 로고
    • Proton dose monitoring with PET: Quantitative studies in Lucite
    • U. Oelfke, G. K. Y. Lam, and M. S. Atkins, "Proton dose monitoring with PET: Quantitative studies in Lucite," Phys. Med. Biol. 41, 177-196 (1996).
    • (1996) Phys. Med. Biol. , vol.41 , pp. 177-196
    • Oelfke, U.1    Lam, G.K.Y.2    Atkins, M.S.3
  • 31
    • 11844249242 scopus 로고
    • Positron emission tomography as an aid to in vivo dosimetry for proton radiotherapy: A Monte Carlo simulation
    • Aug.
    • A. Del Guerra and G. Di Domenico, "Positron Emission Tomography as an aid to in vivo dosimetry for proton radiotherapy: A Monte Carlo simulation," TERA 93/10 TRA 9, Aug. 1993.
    • (1993) TERA 93/10 TRA 9
    • Del Guerra, A.1    Di Domenico, G.2
  • 33
    • 0031207581 scopus 로고    scopus 로고
    • On-line PET monitoring of radiotherapy beams: Image reconstruction and monte carlo simulations of detector geometries
    • D. W. Litzenberg, F. D. Becchetti, and D. A. Roberts, "On-line PET monitoring of radiotherapy beams: Image reconstruction and monte carlo simulations of detector geometries," IEEE Trans. Nucl. Sci. 44, 1646-1657 (1997).
    • (1997) IEEE Trans. Nucl. Sci. , vol.44 , pp. 1646-1657
    • Litzenberg, D.W.1    Becchetti, F.D.2    Roberts, D.A.3
  • 34
    • 0030084547 scopus 로고    scopus 로고
    • A parallel, transputer-based data acquisition system for on-line PET imaging of proton and gamma-ray radiotherapy beams
    • D. W. Litzenberg, F. D. Becchetti, D. A. Roberts, A. M. Vander Molen, and Ron Fox, "A parallel, transputer-based data acquisition system for on-line PET imaging of proton and gamma-ray radiotherapy beams," IEEE Trans. Nucl. Sci. 43, 154-158 (1996).
    • (1996) IEEE Trans. Nucl. Sci. , vol.43 , pp. 154-158
    • Litzenberg, D.W.1    Becchetti, F.D.2    Roberts, D.A.3    Vander Molen, A.M.4    Fox, R.5
  • 44
    • 0030151699 scopus 로고    scopus 로고
    • Calculation and evaluation of cross sections and kerma factors for neutrons up to 100 MeV on carbon
    • M. B. Chadwick and P. G. Young, "Calculation and evaluation of cross sections and kerma factors for neutrons up to 100 MeV on carbon," Nucl. Sci. Eng. 123, 17-37 (1996).
    • (1996) Nucl. Sci. Eng. , vol.123 , pp. 17-37
    • Chadwick, M.B.1    Young, P.G.2
  • 47
    • 0028843714 scopus 로고
    • Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility
    • J. M. Balter, K. L. Lam, H. M. Sandler, J. F. Littles, R. L. Bree, and R. K. Ten Haken, "Automated localization of the prostate at the time of treatment using implanted radiopaque markers: Technical feasibility," Int. J. Radiat. Oncol., Biol., Phys. 33, 1281-1286 (1995).
    • (1995) Int. J. Radiat. Oncol., Biol., Phys. , vol.33 , pp. 1281-1286
    • Balter, J.M.1    Lam, K.L.2    Sandler, H.M.3    Littles, J.F.4    Bree, R.L.5    Ten Haken, R.K.6
  • 48
    • 3142624190 scopus 로고
    • Tables of energy loss and ranges of electrons and positrons
    • edited by U. Fano, Publ. No. 1133 National Academy of Sciences, National Research Council, Washington D.C.
    • M. J. Berger and S. M. Seltzer, "Tables of energy loss and ranges of electrons and positrons," in Studies in Penetration of Charged Particles in Matter, edited by U. Fano, Publ. No. 1133 (National Academy of Sciences, National Research Council, Washington D.C., 1956), pp. 1-30.
    • (1956) Studies in Penetration of Charged Particles in Matter , pp. 1-30
    • Berger, M.J.1    Seltzer, S.M.2
  • 49
    • 0001180310 scopus 로고
    • Proton range-energy tables, 1 keV-10 GeV
    • J. F. Janni, "Proton range-energy tables, 1 keV-10 GeV," At. Data Nucl. Data Tables 27, (1982).
    • (1982) At. Data Nucl. Data Tables , vol.27
    • Janni, J.F.1
  • 50
    • 0040732687 scopus 로고
    • 11C reaction from 50 to 160 MeV
    • 11C reaction from 50 to 160 MeV," Nucl. Phys. 78, 476-480 (1966).
    • (1966) Nucl. Phys. , vol.78 , pp. 476-480
    • Measday, D.F.1
  • 51
    • 0009193855 scopus 로고
    • 11C produced in nitrogen by low-energy protons
    • 11C produced in nitrogen by low-energy protons," Phys. Rev. C 3, 2167-2171 (1971).
    • (1971) Phys. Rev. C , vol.3 , pp. 2167-2171
    • Epherre, M.1    Seide, C.2
  • 52
    • 33744554709 scopus 로고
    • Fonctions d'excitation des reactions (p.Pn) et (p.2p 2n) dans les noyaux legers entre 15 et 155 MeV
    • France
    • L. Valentin, G. Albouy, J. P. Cohen, and M. Gusakow, "Fonctions d'excitation des reactions (p.pn) et (p.2p 2n) dans les noyaux legers entre 15 et 155 MeV," J. Phys. (France) 25, 704-706 (1964).
    • (1964) J. Phys. , vol.25 , pp. 704-706
    • Valentin, L.1    Albouy, G.2    Cohen, J.P.3    Gusakow, M.4
  • 53
    • 0141810080 scopus 로고
    • Gamma radiation from medium energy proton bombardment of lithium, beryllium, boron, carbon and nitrogen
    • A. B. Clegg, "Gamma radiation from medium energy proton bombardment of lithium, beryllium, boron, carbon and nitrogen," Proc. Phys. Soc. 78, 681 (1961).
    • (1961) Proc. Phys. Soc. , vol.78 , pp. 681
    • Clegg, A.B.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.