메뉴 건너뛰기




Volumn 14, Issue 1, 1999, Pages 67-72

Measurement of the emission profiles of cylindrical light diffusers using a video technique

Author keywords

Emission profile; ILP; Light diffuser; PDT; Tissue phantom; Video camera

Indexed keywords

ARTICLE; DIFFUSION; LASER COAGULATION; LASER SURGERY; LIGHT; PHOTODYNAMIC THERAPY; PRIORITY JOURNAL; SPECTRUM; VIDEORECORDING;

EID: 0033056517     PISSN: 02688921     EISSN: None     Source Type: Journal    
DOI: 10.1007/s101030050023     Document Type: Article
Times cited : (13)

References (14)
  • 1
    • 0029619202 scopus 로고
    • Ex vivo light dosimetery and Monte Carlo simulations for endobronchial photodynamic therapy
    • Murrer LH, Marijnissen JP, Star WM. Ex vivo light dosimetery and Monte Carlo simulations for endobronchial photodynamic therapy. Phys Med Biol 1995; 40:1807-17.
    • (1995) Phys Med Biol , vol.40 , pp. 1807-1817
    • Murrer, L.H.1    Marijnissen, J.P.2    Star, W.M.3
  • 2
    • 0025306592 scopus 로고
    • Photodetection and photodynamic therapy of 'early' squamous cell carcinomas of the pharynx, oesophagus and tracheo-bronchial tree
    • Monnier Ph, Savary M, Fontolliet Ch et al. Photodetection and photodynamic therapy of 'early' squamous cell carcinomas of the pharynx, oesophagus and tracheo-bronchial tree. Lasers Med Sci 1990; 5:149-69.
    • (1990) Lasers Med Sci , vol.5 , pp. 149-169
    • Monnier, Ph.1    Savary, M.2    Fontolliet, Ch.3
  • 3
    • 0027278334 scopus 로고
    • Interstatial Nd:YAG laser coagulation with a cylindrical diffusing fibre tip in experimental liver metastases
    • Nolsø CP, Torppedersen S, Andersen PH et al. Interstatial Nd:YAG laser coagulation with a cylindrical diffusing fibre tip in experimental liver metastases. Semin Intervent Radiol 1993; 10:113-24.
    • (1993) Semin Intervent Radiol , vol.10 , pp. 113-124
    • Nolsø, C.P.1    Torppedersen, S.2    Andersen, P.H.3
  • 4
    • 0024953531 scopus 로고
    • A method for the construction of disposable cylindrical diffusing fibre optic tips for use in photodynamic therapy
    • Feather JW, King PR, Driver I et al. A method for the construction of disposable cylindrical diffusing fibre optic tips for use in photodynamic therapy. Lasers Med Sci 1989; 4:229-35.
    • (1989) Lasers Med Sci , vol.4 , pp. 229-235
    • Feather, J.W.1    King, P.R.2    Driver, I.3
  • 5
    • 0343662339 scopus 로고
    • New distributors for homogeneous and monitorable light delivery in photodynamic therapy
    • Mizeret J, Thielen P, Theumann J-F et al. New distributors for homogeneous and monitorable light delivery in photodynamic therapy. Proc SPIE 1995; 2323:58-69.
    • (1995) Proc SPIE , vol.2323 , pp. 58-69
    • Mizeret, J.1    Thielen, P.2    Theumann, J.-F.3
  • 6
    • 0029763389 scopus 로고    scopus 로고
    • Calibration of isotropic light dosimetery detectors based on scattering bulbs in clear media
    • Marijnissen JPA, Star WM. Calibration of isotropic light dosimetery detectors based on scattering bulbs in clear media. Phys Med Biol 1996; 41:1191-208.
    • (1996) Phys Med Biol , vol.41 , pp. 1191-1208
    • Marijnissen, J.P.A.1    Star, W.M.2
  • 7
    • 0342357079 scopus 로고
    • Application equipment for intraoperative and percutaneous laser-induced interstitial thermotherapy (LITT)
    • Roggan A, Albrecht D, Berlien H-P et al. Application equipment for intraoperative and percutaneous laser-induced interstitial thermotherapy (LITT). Proc SPIE 1995; PM25:213-14.
    • (1995) Proc SPIE , vol.PM25 , pp. 213-214
    • Roggan, A.1    Albrecht, D.2    Berlien, H.-P.3
  • 8
    • 0029893730 scopus 로고    scopus 로고
    • Light distribution by linear diffusing sources for photodynamic therapy
    • Murrer LHP, Marijnissen JPA, Star WM. Light distribution by linear diffusing sources for photodynamic therapy. Phys Med Biol 1996; 41:951-61.
    • (1996) Phys Med Biol , vol.41 , pp. 951-961
    • Murrer, L.H.P.1    Marijnissen, J.P.A.2    Star, W.M.3
  • 9
    • 0028532382 scopus 로고
    • Three-dimensional characterisation of the light distribution from diffusing cylindrical optical fibre tips
    • Kozodoy RL, Lundahl SC, Bell D et al. Three-dimensional characterisation of the light distribution from diffusing cylindrical optical fibre tips. Appl Opt 1994; 28:6674-82.
    • (1994) Appl Opt , vol.28 , pp. 6674-6682
    • Kozodoy, R.L.1    Lundahl, S.C.2    Bell, D.3
  • 10
    • 0344949141 scopus 로고
    • Measurement of a laser-beam profile by using a video camera
    • Nishioka NS, Bua DP, Deutsch TF. Measurement of a laser-beam profile by using a video camera. Lasers Med Sci 1987; 2:21-3.
    • (1987) Lasers Med Sci , vol.2 , pp. 21-23
    • Nishioka, N.S.1    Bua, D.P.2    Deutsch, T.F.3
  • 12
    • 84966607889 scopus 로고
    • Light scattering in intralipid 10% in the wavelength range 400-1100 nm
    • Van Staveren HJ, Moes CJM, Van Marle J et al. Light scattering in Intralipid 10% in the wavelength range 400-1100 nm. Appl Opt 1991; 30:4507-14.
    • (1991) Appl Opt , vol.30 , pp. 4507-4514
    • Van Staveren, H.J.1    Moes, C.J.M.2    Van Marle, J.3
  • 13
    • 0026630107 scopus 로고
    • Optical properties of intralipid: A phantom medium for light propagation studies
    • Flock ST, Jacques SL, Wilson BC et al. Optical properties of Intralipid: a phantom medium for light propagation studies. Lasers Surg Med 1992; 12:510-19.
    • (1992) Lasers Surg Med , vol.12 , pp. 510-519
    • Flock, S.T.1    Jacques, S.L.2    Wilson, B.C.3
  • 14
    • 0030754475 scopus 로고    scopus 로고
    • Improvements in the design of linear diffusers for photodynamic therapy
    • Murrer LHP, Marijnissen JPA, Star WM. Improvements in the design of linear diffusers for photodynamic therapy. Phys Med Biol 1997; 42:1461-4.
    • (1997) Phys Med Biol , vol.42 , pp. 1461-1464
    • Murrer, L.H.P.1    Marijnissen, J.P.A.2    Star, W.M.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.