메뉴 건너뛰기




Volumn 8, Issue 1, 1999, Pages 85-95

A new flow model for Doppler ultrasound study of prosthetic heart valves

Author keywords

[No Author keywords available]

Indexed keywords

AORTA PRESSURE; ARTICLE; DOPPLER ECHOGRAPHY; FLOW; HEART LEFT VENTRICLE PRESSURE; HEART VALVE PROSTHESIS; HUMAN; HYDRODYNAMICS; MODEL; PRESSURE GRADIENT; PRIORITY JOURNAL;

EID: 0033056498     PISSN: 09668519     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (16)

References (33)
  • 1
    • 0018876715 scopus 로고
    • Non-invasive assessment of aortic stenosis by Doppler ultrasound
    • Hatle L, Angelsen BAJ, Tromsd A. Non-invasive assessment of aortic stenosis by Doppler ultrasound. Br Heart J 1980;43:284-292
    • (1980) Br Heart J , vol.43 , pp. 284-292
    • Hatle, L.1    Angelsen, B.A.J.2    Tromsd, A.3
  • 2
    • 0022355265 scopus 로고
    • Noninvasive estimation of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography
    • Skjaerpe T, Hegrenaes L, Hatle L. Noninvasive estimation of valve area in patients with aortic stenosis by Doppler ultrasound and two-dimensional echocardiography. Circulation 1985;7:810-818
    • (1985) Circulation , vol.7 , pp. 810-818
    • Skjaerpe, T.1    Hegrenaes, L.2    Hatle, L.3
  • 3
    • 0025346848 scopus 로고
    • Determination of aortic valve area by two-dimensional and Doppler echocardiography in patients with normal and stenotic bioprosthetic valves
    • Rothbart RM, Castriz JL, Harding LV, Russo CD, Teague SM. Determination of aortic valve area by two-dimensional and Doppler echocardiography in patients with normal and stenotic bioprosthetic valves. J Am Coll Cardiol 1990;15:817-824
    • (1990) J Am Coll Cardiol , vol.15 , pp. 817-824
    • Rothbart, R.M.1    Castriz, J.L.2    Harding, L.V.3    Russo, C.D.4    Teague, S.M.5
  • 4
    • 0026026862 scopus 로고
    • Doppler echocardiographic assessment of the St. Jude Medical prosthetic valve in the aortic position using the continuity equation
    • Chafizadeh ER, Zoghbi WA. Doppler echocardiographic assessment of the St. Jude Medical prosthetic valve in the aortic position using the continuity equation. Circulation 1991;83:213-223
    • (1991) Circulation , vol.83 , pp. 213-223
    • Chafizadeh, E.R.1    Zoghbi, W.A.2
  • 5
    • 0025793356 scopus 로고
    • Theoretical and practical differences between the Gorlin formula and the continuity equation for calculating aortic and mitral valve areas
    • Dumesnil JG, Yoganathan AP. Theoretical and practical differences between the Gorlin formula and the continuity equation for calculating aortic and mitral valve areas. Am J Cardiol 1991;67:1268-1272
    • (1991) Am J Cardiol , vol.67 , pp. 1268-1272
    • Dumesnil, J.G.1    Yoganathan, A.P.2
  • 6
    • 0025179228 scopus 로고
    • Validation and applications of indexed aortic prosthetic valve areas calculated by Doppler echocardiography
    • Dumesnil JG, Honos GN, Lemieux M, Beauchemin J. Validation and applications of indexed aortic prosthetic valve areas calculated by Doppler echocardiography. J Am Coll Cardiol 1990;16:637-643
    • (1990) J Am Coll Cardiol , vol.16 , pp. 637-643
    • Dumesnil, J.G.1    Honos, G.N.2    Lemieux, M.3    Beauchemin, J.4
  • 7
    • 0029337145 scopus 로고
    • Substitution of left ventricular outflow tract diameter with prosthesis size is inadequate for calculation of the aortic prosthetic valve area by the continuity equation
    • Pibarot P, Honos GN, Durand LG, Dumesnil JG. Substitution of left ventricular outflow tract diameter with prosthesis size is inadequate for calculation of the aortic prosthetic valve area by the continuity equation. J Am Soc Echocardiogr 1995;8:511-17
    • (1995) J Am Soc Echocardiogr , vol.8 , pp. 511-517
    • Pibarot, P.1    Honos, G.N.2    Durand, L.G.3    Dumesnil, J.G.4
  • 8
    • 0025341168 scopus 로고
    • Validation and applications of mitral prosthetic valvular areas calculated by Doppler echocardiography
    • Dumesnil JG, Honos GN, Lemieux M, Beauchemin J. Validation and applications of mitral prosthetic valvular areas calculated by Doppler echocardiography. Am J Cardiol 1990;65:1443-1448
    • (1990) Am J Cardiol , vol.65 , pp. 1443-1448
    • Dumesnil, J.G.1    Honos, G.N.2    Lemieux, M.3    Beauchemin, J.4
  • 9
    • 0026487659 scopus 로고
    • In vitro pulsatile flow hemodynamics of five mechanical aortic heart valve prostheses
    • Walker PG, Yoganathan AP. In vitro pulsatile flow hemodynamics of five mechanical aortic heart valve prostheses. Eur J Cardiothorac Surg 1992;6(suppl.I):S113-S123
    • (1992) Eur J Cardiothorac Surg , vol.6 , Issue.SUPPL.I
    • Walker, P.G.1    Yoganathan, A.P.2
  • 10
    • 0027552897 scopus 로고
    • Assessment of prosthetic valve hemodynamics by Doppler: Lessons from in vitro studies of the St. Jude valve
    • Khan SS. Assessment of prosthetic valve hemodynamics by Doppler: Lessons from in vitro studies of the St. Jude valve. J Heart Valve Dis 1993;2:183-193
    • (1993) J Heart Valve Dis , vol.2 , pp. 183-193
    • Khan, S.S.1
  • 11
    • 0025232311 scopus 로고
    • Influence of orifice geometry and flow rate on effective valve area: An in vitro study
    • Flachskampf FA, Weyman AE, Guerrero JL, Thomas JD. Influence of orifice geometry and flow rate on effective valve area: An in vitro study. J Am Coll Cardiol 1990;15:1173-1180
    • (1990) J Am Coll Cardiol , vol.15 , pp. 1173-1180
    • Flachskampf, F.A.1    Weyman, A.E.2    Guerrero, J.L.3    Thomas, J.D.4
  • 12
    • 0026512411 scopus 로고
    • Effect of prosthetic aortic valve design on the Doppler-catheter gradient correlation: An in vitro study of normal St. Jude, Medtronic-Hall, Starr-Edwards and Hancock valves
    • Baumgartner H, Khan SS, DeRobertis M, Czer LS, Maurer G. Effect of prosthetic aortic valve design on the Doppler-catheter gradient correlation: An in vitro study of normal St. Jude, Medtronic-Hall, Starr-Edwards and Hancock valves. J Am Coll Cardiol 1992;19:324-332
    • (1992) J Am Coll Cardiol , vol.19 , pp. 324-332
    • Baumgartner, H.1    Khan, S.S.2    DeRobertis, M.3    Czer, L.S.4    Maurer, G.5
  • 13
    • 0027070923 scopus 로고
    • Pressure recovery in aortic stenosis: An in vitro study in a pulsatile flow model
    • Voelker W, Reul H, Stelzer T, Schmidt A, Karsch KR. Pressure recovery in aortic stenosis: An in vitro study in a pulsatile flow model. J Am Coll Cardiol 1992;20:1585-1593
    • (1992) J Am Coll Cardiol , vol.20 , pp. 1585-1593
    • Voelker, W.1    Reul, H.2    Stelzer, T.3    Schmidt, A.4    Karsch, K.R.5
  • 14
    • 0025552864 scopus 로고
    • Discrepancies between Doppler and catheter gradients in aortic prosthetic valves in vitro. A manifestation of localized gradients and pressure recovery
    • Baumgartner H, Khan SS, DeRobertis M, Czer LS, Maurer G. Discrepancies between Doppler and catheter gradients in aortic prosthetic valves in vitro. A manifestation of localized gradients and pressure recovery. Circulation 1990;82:1467-1475
    • (1990) Circulation , vol.82 , pp. 1467-1475
    • Baumgartner, H.1    Khan, S.S.2    Derobertis, M.3    Czer, L.S.4    Maurer, G.5
  • 16
    • 0028853909 scopus 로고
    • Pressure recovery in bileaflet heart valve prostheses. Localized high velocities and gradients in central and side orifices with implications for Doppler-catheter gradient relation in aortic and mitral position
    • Vandervoort PM, Greenberg NL, Pu M, Powell KA, Cosgrove DM, Thomas JD. Pressure recovery in bileaflet heart valve prostheses. Localized high velocities and gradients in central and side orifices with implications for Doppler-catheter gradient relation in aortic and mitral position. Circulation 1995;92:3464-3472
    • (1995) Circulation , vol.92 , pp. 3464-3472
    • Vandervoort, P.M.1    Greenberg, N.L.2    Pu, M.3    Powell, K.A.4    Cosgrove, D.M.5    Thomas, J.D.6
  • 18
    • 0029825136 scopus 로고    scopus 로고
    • Importance of pressure recovery for the assessment of aortic stenosis by Doppler Ultrasound. Role of aortic size, aortic valve area, and direction of the stenotic jet in vitro
    • Niederberger J, Schima H, Maurer G, Baumgartner H. Importance of pressure recovery for the assessment of aortic stenosis by Doppler Ultrasound. Role of aortic size, aortic valve area, and direction of the stenotic jet in vitro. Circulation 1996;94:1934-1940
    • (1996) Circulation , vol.94 , pp. 1934-1940
    • Niederberger, J.1    Schima, H.2    Maurer, G.3    Baumgartner, H.4
  • 19
    • 0027431835 scopus 로고
    • Velocity distributions in the left ventricular outflow tract and the aortic anulus measured with Doppler colour flow mapping in normal subjects
    • Zhou YQ, Faerestrand S, Matre K, Birkeland S. Velocity distributions in the left ventricular outflow tract and the aortic anulus measured with Doppler colour flow mapping in normal subjects. Eur Heart J 1993;14:1179-1188
    • (1993) Eur Heart J , vol.14 , pp. 1179-1188
    • Zhou, Y.Q.1    Faerestrand, S.2    Matre, K.3    Birkeland, S.4
  • 21
    • 0028854711 scopus 로고
    • Limitations of Doppler echocardiography in the assessment of prosthetic valve hemodynamics
    • Henneke KH, Pongratz G, Bachmann K. Limitations of Doppler echocardiography in the assessment of prosthetic valve hemodynamics. J Heart Valve Dis 1995;4:18-25
    • (1995) J Heart Valve Dis , vol.4 , pp. 18-25
    • Henneke, K.H.1    Pongratz, G.2    Bachmann, K.3
  • 22
    • 0026199244 scopus 로고
    • The velocity distribution in the aortic anulus in normal subjects: A quantitative analysis of two-dimensional Doppler flow maps
    • Rossvoll O, Samstad S, Torp HG, Linker DT, Skjaerpe T, Angelsen BAJ, Hatle L. The velocity distribution in the aortic anulus in normal subjects: A quantitative analysis of two-dimensional Doppler flow maps. J Am Soc Echocardiogr 1991;4:367-378
    • (1991) J Am Soc Echocardiogr , vol.4 , pp. 367-378
    • Rossvoll, O.1    Samstad, S.2    Torp, H.G.3    Linker, D.T.4    Skjaerpe, T.5    Angelsen, B.A.J.6    Hatle, L.7
  • 23
    • 0027604499 scopus 로고
    • Cross-sectional left ventricular outflow tract velocities before and after aortic valve replacement: A comparative study with two-dimensional Doppler ultrasound
    • Wiseth R, Samstad S, Rossvoll O, Torp HG, Skjaerpe T, Hatle L. Cross-sectional left ventricular outflow tract velocities before and after aortic valve replacement: A comparative study with two-dimensional Doppler ultrasound. J Am Soc Echocardiogr 1993;6:279-285
    • (1993) J Am Soc Echocardiogr , vol.6 , pp. 279-285
    • Wiseth, R.1    Samstad, S.2    Rossvoll, O.3    Torp, H.G.4    Skjaerpe, T.5    Hatle, L.6
  • 24
    • 0031967532 scopus 로고    scopus 로고
    • Utility of three-dimensional ultrasound Doppler flow reconstruction of the proximal jet to quantify effective orifice area: In vitro steady and pulsatile flow studies
    • Shandas R, DeGroff CG, Kwon J, Trujillo N, Gill EA, Valdes-Cruz L. Utility of three-dimensional ultrasound Doppler flow reconstruction of the proximal jet to quantify effective orifice area: In vitro steady and pulsatile flow studies. J Am Soc Echocardiogr 1998;11:313-321
    • (1998) J Am Soc Echocardiogr , vol.11 , pp. 313-321
    • Shandas, R.1    Degroff, C.G.2    Kwon, J.3    Trujillo, N.4    Gill, E.A.5    Valdes-Cruz, L.6
  • 25
    • 0024334066 scopus 로고
    • On the design and evaluation of a steady flow model for Doppler ultrasound studies
    • Law YF, Johnston KW, Routh HF, Cobbold RSC. On the design and evaluation of a steady flow model for Doppler ultrasound studies. Ultrasound Med Biol 1989;15:505-516
    • (1989) Ultrasound Med Biol , vol.15 , pp. 505-516
    • Law, Y.F.1    Johnston, K.W.2    Routh, H.F.3    Cobbold, R.S.C.4
  • 26
    • 0018395195 scopus 로고
    • Pressure drops across prosthetic aortic heart valves under steady and pulsatile flow. in vitro measurements
    • Yoganathan AP, Corcoran WH, Harrison EC. Pressure drops across prosthetic aortic heart valves under steady and pulsatile flow. In vitro measurements. J Biomech 1979;12:153-164
    • (1979) J Biomech , vol.12 , pp. 153-164
    • Yoganathan, A.P.1    Corcoran, W.H.2    Harrison, E.C.3
  • 27
    • 0031282201 scopus 로고    scopus 로고
    • Velocity measurements within confined turbulent jets: Application to cardiovascular regurgitation
    • Liu H, Winoto SH, Shah DA. Velocity measurements within confined turbulent jets: Application to cardiovascular regurgitation. Ann Biomed Eng 1997;22:939-948
    • (1997) Ann Biomed Eng , vol.22 , pp. 939-948
    • Liu, H.1    Winoto, S.H.2    Shah, D.A.3
  • 28
    • 0024661880 scopus 로고
    • A computerized physiologic pulse duplicator for in vitro hydrodynamic and ultrasonic studies of prosthetic heart valves
    • Arabia FA, Talbot TL, Stewart SFC, Nast EP, Clark RE. A computerized physiologic pulse duplicator for in vitro hydrodynamic and ultrasonic studies of prosthetic heart valves. Biomed Instrument Technol 1989;23:205-215
    • (1989) Biomed Instrument Technol , vol.23 , pp. 205-215
    • Arabia, F.A.1    Talbot, T.L.2    Stewart, S.F.C.3    Nast, E.P.4    Clark, R.E.5
  • 29
    • 0026754569 scopus 로고
    • A modular mock circulation for hydromechanical studies on valves, stenoses, vascular grafts and cardiac assist devices
    • Schima H, Baumgartner H, Spitaler F, Kuhn P, Wolner E. A modular mock circulation for hydromechanical studies on valves, stenoses, vascular grafts and cardiac assist devices. Int J Artif Organs 1992;15:417-421
    • (1992) Int J Artif Organs , vol.15 , pp. 417-421
    • Schima, H.1    Baumgartner, H.2    Spitaler, F.3    Kuhn, P.4    Wolner, E.5
  • 30
    • 0031920151 scopus 로고    scopus 로고
    • In vitro evaluation of multiple arterial stenoses using three-dimensional power Doppler angiography
    • Guo Z, Durand LG, Allard L, Cloutier G, Fenster A. In vitro evaluation of multiple arterial stenoses using three-dimensional power Doppler angiography. J Vasc Surg 1998;27:681-688
    • (1998) J Vasc Surg , vol.27 , pp. 681-688
    • Guo, Z.1    Durand, L.G.2    Allard, L.3    Cloutier, G.4    Fenster, A.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.