메뉴 건너뛰기




Volumn 14, Issue 3, 1999, Pages 688-691

Percutaneous fibrin sleeve stripping of failing haemodialysis catheters

Author keywords

Catheter; Fibrin; Haemodialysis; Sheath; Stripping

Indexed keywords

FIBRIN;

EID: 0033045615     PISSN: 09310509     EISSN: None     Source Type: Journal    
DOI: 10.1093/ndt/14.3.688     Document Type: Article
Times cited : (30)

References (9)
  • 1
    • 84943443109 scopus 로고
    • Fibrin sleeve formation on indwelling subclavian central venous catheters
    • Hoshal VL, Ause RG, Hoskins PA. Fibrin sleeve formation on indwelling subclavian central venous catheters. Arch Surg 1971; 102: 353-358
    • (1971) Arch Surg , vol.102 , pp. 353-358
    • Hoshal, V.L.1    Ause, R.G.2    Hoskins, P.A.3
  • 2
    • 0028432811 scopus 로고
    • Fibrin sheath entrapment of peripherally inserted central catheters
    • Cardella IF, Lukens ML, Fox PS. Fibrin sheath entrapment of peripherally inserted central catheters. JVIR 1994; 5: 439-442
    • (1994) JVIR , vol.5 , pp. 439-442
    • Cardella, I.F.1    Lukens, M.L.2    Fox, P.S.3
  • 3
    • 0026603695 scopus 로고
    • Thrombosed central venous catheters: Restoring function with a 6-hour uroknase infusion after failure of bolus injection
    • Haire WD, Lieberman RP. Thrombosed central venous catheters: restoring function with a 6-hour uroknase infusion after failure of bolus injection. JPEN 1992; 16: 129-132
    • (1992) JPEN , vol.16 , pp. 129-132
    • Haire, W.D.1    Lieberman, R.P.2
  • 5
    • 0344027153 scopus 로고
    • Functional restoration of occluded central venous catheters: New interventional techniques
    • Abstract
    • Knelson MH, Newman GE, Sallec DS, Suhocki PV. Functional restoration of occluded central venous catheters: new interventional techniques. JVIR 1993; 4: 36 (Abstract)
    • (1993) JVIR , vol.4 , pp. 36
    • Knelson, M.H.1    Newman, G.E.2    Sallec, D.S.3    Suhocki, P.V.4
  • 6
    • 0025871822 scopus 로고
    • Five years experience with the Quinton PermCath for vascular access
    • Gibson SP, Mosqucera D. Five years experience with the Quinton PermCath for vascular access. Nephrol Dial Transplant 1991; 6: 269-274
    • (1991) Nephrol Dial Transplant , vol.6 , pp. 269-274
    • Gibson, S.P.1    Mosqucera, D.2
  • 8
    • 85038173365 scopus 로고
    • Permanent dual lumen catheters for long term haemodialysis: Factors influencing catheter survival
    • Edinburgh 4-5 November
    • Akoh JA, Akyol MA. Permanent dual lumen catheters for long term haemodialysis: factors influencing catheter survival. Autumn Meeting of the Scottish Renal Association, Edinburgh 4-5 November 1994
    • (1994) Autumn Meeting of the Scottish Renal Association
    • Akoh, J.A.1    Akyol, M.A.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.