메뉴 건너뛰기




Volumn 44, Issue 6, 1999, Pages

Pulsed EPR imaging: Image reconstruction using selective acquisition sequences

Author keywords

[No Author keywords available]

Indexed keywords

ANALOG DIGITAL CONVERTER; ARTICLE; ELECTRON SPIN RESONANCE; IMAGE RECONSTRUCTION; MAGNETIC FIELD; PRIORITY JOURNAL; RELAXATION TIME; SIMULATION; TECHNIQUE;

EID: 0033034226     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/44/6/409     Document Type: Article
Times cited : (5)

References (12)
  • 1
    • 0000249762 scopus 로고    scopus 로고
    • A radiofrequency (220 MHz) Fourier transform EPR spectrometer
    • Alecci M, Brivati J A, Placidi G and Sotgiu A 1998 A radiofrequency (220 MHz) Fourier transform EPR spectrometer J. Magn. Reson. 130 272-80
    • (1998) J. Magn. Reson. , vol.130 , pp. 272-280
    • Alecci, M.1    Brivati, J.A.2    Placidi, G.3    Sotgiu, A.4
  • 2
    • 0027998841 scopus 로고
    • Simultaneous 280 MHz EPR imaging of rat organs during nitroxide free radical clearance
    • Alecci M, Ferrari M, Quaresima V, Sotgiu A and Ursini C L 1994 Simultaneous 280 MHz EPR imaging of rat organs during nitroxide free radical clearance Biophys. J. 67 1274-9
    • (1994) Biophys. J. , vol.67 , pp. 1274-1279
    • Alecci, M.1    Ferrari, M.2    Quaresima, V.3    Sotgiu, A.4    Ursini, C.L.5
  • 5
    • 0000294172 scopus 로고
    • A radiofrequency ESR spectrometer for in vivo imaging
    • Brivati J, Stevens A D and Symons M C R 1991 A radiofrequency ESR spectrometer for in vivo imaging J. Magn. Reson. 92 480-5
    • (1991) J. Magn. Reson. , vol.92 , pp. 480-485
    • Brivati, J.1    Stevens, A.D.2    Symons, M.C.R.3
  • 7
    • 0022694636 scopus 로고
    • 6 by the electron spin echo field gradient technique
    • 6 by the electron spin echo field gradient technique Physica B 138 261-8
    • (1986) Physica B , vol.138 , pp. 261-268
    • Emid, S.1    Maresch, G.G.2    Mehring, M.3
  • 8
  • 9
    • 85052565430 scopus 로고
    • Resolution in EPR imaging
    • ed G R Eaton, S S Eaton and K Ohno (Boca Raton, FL: CRC)
    • Hoch M J R and Ewert U 1991 Resolution in EPR imaging EPR Imaging and In Vivo EPR ed G R Eaton, S S Eaton and K Ohno (Boca Raton, FL: CRC) pp 153-9
    • (1991) EPR Imaging and In Vivo EPR , pp. 153-159
    • Hoch, M.J.R.1    Ewert, U.2
  • 10
    • 0030975538 scopus 로고    scopus 로고
    • High resolution electron paramagnetic resonance imaging of biological samples with a single line paramagnetic label
    • Kuppusamy P, Wang P, Chzhan M and Zweier J L 1997 High resolution electron paramagnetic resonance imaging of biological samples with a single line paramagnetic label Magn. Reson. Med. 37 479-83
    • (1997) Magn. Reson. Med. , vol.37 , pp. 479-483
    • Kuppusamy, P.1    Wang, P.2    Chzhan, M.3    Zweier, J.L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.