Radiological thickness measurement using a liquid ionization chamber electronic portal imaging device

Author keywords

[No Author keywords available]

Indexed keywords

ACCURACY; ARTICLE; CALIBRATION; DOSE RESPONSE; ERROR; IMAGING SYSTEM; IONIZATION CHAMBER; MODEL; PRIORITY JOURNAL; THICKNESS;

EID: 0033033732     PISSN: 00319155     EISSN: None     Source Type: Journal    
DOI: 10.1088/0031-9155/44/6/403     Document Type: Article
Times cited : (11)

References (14)
  • 1
    • 0029814510 scopus 로고    scopus 로고
    • The dose response relationship of a liquid-filled electronic portal imaging device
    • Boellaard R, van Herk M and Mijnheer B J 1996 The dose response relationship of a liquid-filled electronic portal imaging device Med. Phys. 23 1601-11
    • (1996) Med. Phys. , vol.23 , pp. 1601-1611
    • Boellaard, R.1    Van Herk, M.2    Mijnheer, B.J.3
  • 2
    • 0031045088 scopus 로고    scopus 로고
    • A convolution model to convert transmission dose images to exit dose distributions
    • _1997 A convolution model to convert transmission dose images to exit dose distributions Med. Phys. 24 189-99
    • (1997) Med. Phys. , vol.24 , pp. 189-199
  • 4
    • 0030002611 scopus 로고    scopus 로고
    • The application of transit dosimetry to precision radiotherapy
    • Hansen V N, Evans P M and Swindell W 1996 The application of transit dosimetry to precision radiotherapy Med. Phys. 23 713-21
    • (1996) Med. Phys. , vol.23 , pp. 713-721
    • Hansen, V.N.1    Evans, P.M.2    Swindell, W.3
  • 5
    • 0028857468 scopus 로고
    • The use of an electronic portal imaging device for exit dosimetry and quality control measurements
    • Kirby M C and Williams P C 1995 The use of an electronic portal imaging device for exit dosimetry and quality control measurements Int. J. Radiat. Oncol. Biol. Phys. 31 593-603
    • (1995) Int. J. Radiat. Oncol. Biol. Phys. , vol.31 , pp. 593-603
    • Kirby, M.C.1    Williams, P.C.2
  • 8
    • 0031711211 scopus 로고    scopus 로고
    • The practical implementation of a scatter model for portal imaging at 10 MV
    • Partridge M and Evans P M 1998 The practical implementation of a scatter model for portal imaging at 10 MV Phys. Med. Biol. 43 2685-93
    • (1998) Phys. Med. Biol. , vol.43 , pp. 2685-2693
    • Partridge, M.1    Evans, P.M.2
  • 9
    • 0028803297 scopus 로고
    • Evaluation of electronic portal imaging device for missing tissue compensator design and verification
    • Roback D M and Gerbi B J 1995 Evaluation of electronic portal imaging device for missing tissue compensator design and verification Med. Phys. 22 2029-34
    • (1995) Med. Phys. , vol.22 , pp. 2029-2034
    • Roback, D.M.A.1    Gerbi, B.J.2
  • 10
    • 0030047716 scopus 로고    scopus 로고
    • Scattered radiation in portal images: A Monte Carlo simulation and a simple physical model
    • Swindell W and Evans P 1996 Scattered radiation in portal images: a Monte Carlo simulation and a simple physical model Med. Phys. 23 63-73
    • (1996) Med. Phys. , vol.23 , pp. 63-73
    • Swindell, W.1    Evans, P.2
  • 12
    • 0023885087 scopus 로고
    • A matrix ionization chamber for on-line patient setup verification during radiotherapy
    • Van Herk M and Meertens H 1988 A matrix ionization chamber for on-line patient setup verification during radiotherapy Radiother. Oncol. 11 369-78
    • (1988) Radiother. Oncol. , vol.11 , pp. 369-378
    • Van Herk, M.1    Meertens, H.2
  • 13
    • 0028145651 scopus 로고
    • Input/output characteristics of a matrix ion-chamber electronic portal imaging device
    • Yin F F, Schell M C and Rubin P 1994a Input/output characteristics of a matrix ion-chamber electronic portal imaging device Med. Phys. 21 1447-54
    • (1994) Med. Phys. , vol.21 , pp. 1447-1454
    • Yin, F.F.1    Schell, M.C.2    Rubin, P.3
  • 14
    • 0028149975 scopus 로고
    • A technique of automating compensator design for lung inhomogeneity correction using an electron portal imaging device
    • _1994b A technique of automating compensator design for lung inhomogeneity correction using an electron portal imaging device Med. Phys. 21 1729-32
    • (1994) Med. Phys. , vol.21 , pp. 1729-1732


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.