메뉴 건너뛰기




Volumn 23, Issue 5, 1999, Pages 566-568

Infection of submucosal tumor after endosonography-guided fine needle- aspiration biopsy;Infection d'une tumeur sous-muqueuse apres ponction sous echo- endoscopie

Author keywords

Biopsy; Complication; Endosonography; Leiomyoma

Indexed keywords

ARTICLE; CASE REPORT; DIFFERENTIAL DIAGNOSIS; ENDOSCOPIC ECHOGRAPHY; ESOPHAGUS TUMOR; GASTROINTESTINAL TUMOR; HUMAN; HUMAN TISSUE; INFECTIOUS COMPLICATION; LEIOMYOMA; LEIOMYOSARCOMA; MALE; NEEDLE BIOPSY;

EID: 0033031424     PISSN: 03998320     EISSN: None     Source Type: Journal    
DOI: None     Document Type: Article
Times cited : (14)

References (8)
  • 1
    • 0030914312 scopus 로고    scopus 로고
    • Endosonography-guided fine-needle aspiration biopsy: Diagnostic accuracy and complication assessment
    • Wiersema, Vilmann P, Giovannini M, Chang KJ, Wiersema LM. Endosonography-guided fine-needle aspiration biopsy: diagnostic accuracy and complication assessment. Gastroenterology 1997; 112:1087-95.
    • (1997) Gastroenterology , vol.112 , pp. 1087-1095
    • Wiersema1    Vilmann, P.2    Giovannini, M.3    Chang, K.J.4    Wiersema, L.M.5
  • 2
    • 0030794899 scopus 로고    scopus 로고
    • Endoscopic ultrasound-guided fine needle aspiration biopsy using linear array and radial scanning endosonography
    • Gress FG, Hawes RH, Savides TJ, Ikeberry SO, Lehman GA. Endoscopic ultrasound-guided fine needle aspiration biopsy using linear array and radial scanning endosonography. Gastrointest Endosc 1997;45:243-50.
    • (1997) Gastrointest Endosc , vol.45 , pp. 243-250
    • Gress, F.G.1    Hawes, R.H.2    Savides, T.J.3    Ikeberry, S.O.4    Lehman, G.A.5
  • 3
    • 0030344609 scopus 로고    scopus 로고
    • Endosonography and endosonography-guided biopsy of upper-GI-tract tumors using a curved-array echoendoscope
    • Hunerbein M, Dohmoto M, Rau B, Schlag PM. Endosonography and endosonography-guided biopsy of upper-GI-tract tumors using a curved-array echoendoscope. Surg Endosc 1996;10: 1205-9.
    • (1996) Surg Endosc , vol.10 , pp. 1205-1209
    • Hunerbein, M.1    Dohmoto, M.2    Rau, B.3    Schlag, P.M.4
  • 5
    • 0029817125 scopus 로고    scopus 로고
    • Endoscopic ultrasound-guided histologic needle biopsy: Preliminary results using a newly developed endoscopic ultrasound transducer
    • Harada N, Kouzu T, Arima M, Isono K. Endoscopic ultrasound-guided histologic needle biopsy: preliminary results using a newly developed endoscopic ultrasound transducer. Gastrointest Endosc 1996;44:327-30.
    • (1996) Gastrointest Endosc , vol.44 , pp. 327-330
    • Harada, N.1    Kouzu, T.2    Arima, M.3    Isono, K.4
  • 6
    • 0022361302 scopus 로고
    • Smooth muscle tumors of the gastrointestinal tract: A study of 56 cases followed for a minimum of 10 years
    • Evans HL. Smooth muscle tumors of the gastrointestinal tract: a study of 56 cases followed for a minimum of 10 years. Cancer 1985;56:2242-50.
    • (1985) Cancer , vol.56 , pp. 2242-2250
    • Evans, H.L.1
  • 7
    • 0030455805 scopus 로고    scopus 로고
    • Ponction-biopsie guidée sous échoendoscopie. Résultats et indications
    • Giovannini M. Ponction-biopsie guidée sous échoendoscopie. Résultats et indications. Acta Endosc 1996;27:313-6.
    • (1996) Acta Endosc , vol.27 , pp. 313-316
    • Giovannini, M.1
  • 8
    • 0029972869 scopus 로고    scopus 로고
    • A new biopsy handle instrument for endoscopic ultrasound-guided fine-needle aspiration biopsy
    • Vilmann P, Hancke S. A new biopsy handle instrument for endoscopic ultrasound-guided fine-needle aspiration biopsy. Gastrointest Endosc 1996;43:238-42.
    • (1996) Gastrointest Endosc , vol.43 , pp. 238-242
    • Vilmann, P.1    Hancke, S.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.